• Title/Summary/Keyword: Powering

Search Result 173, Processing Time 0.025 seconds

A Study on On-board ATO/TWC Antenna Design and Manufacture (차상 ATO/TWC 안테나 설계 및 제작에 관한 연구)

  • Yoo Sung-Ho;Park chong chon;Kang Lee-Taeg;Cho Young-Wan;Cha Ji-Ju
    • Proceedings of the KSR Conference
    • /
    • 2005.05a
    • /
    • pp.903-908
    • /
    • 2005
  • Existing ATC/ATO/TWC system has a ATC(Automatic Train Control) antenna for receiving the speed code, a ATO(Automatic Train Operation) antenna for obtaining the exact distance to go to platform and TWC(Train and Wayside Communication) antenna for communication between on-board and wayside system. This paper proposes the ATO/TWC antenna with tele-powering module, telegram transmitter/receiver module. This antenna communicates with a passive type tag(wayside Precision Stop Marker) for the information of distance from the stop position and a active type tag for the door command and status in the platform.

  • PDF

Analysis of conducted EMI source on powering mode of next generation high-speed train (차세대 고속전철 주행에 따른 전도성 노이즈 요인분석)

  • Kim, Jae-Moon;Kim, Sei-Chan;Kim, Hak-Man
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.948-949
    • /
    • 2008
  • In this paper, an effect on power conversion unit in next generation high-speed train by loss of contact between a contact wire and pantograph supplied electrical power to high-speed train are investigated. One of the most important needs accompanied by increasing the speed of high-speed train is reduced that arc phenomenon by loss of contact brings out EMI. To analysis of conducted EMI source on powering mode of next generation high-speed train, it is necessary electrical modeling system between the contact wire and the pantograph according with loss of contact. Therefore analytical model of a contact wire and a pantograph is constructed to simulate the behaviour of loss of contact. The reliability of the modeling system is verified by simulation implementation on loss of contact.

  • PDF

Data Acquisition and Analysis for Running Performance Evaluation of the Electric Train (전동차 주행성능평가를 위한 데이터취득 및 분석)

  • Lee, K.W.;Kim, M.Y.;Baik, K.S.;Shim, J.B.;Chang, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.1099-1100
    • /
    • 2006
  • The running of the electric train are done by powering, breaking and coasting. Powering to start and accelerate the rolling stock means driving the three-phase electric induction motors controlled by VVVF inverters which are connected to overhead power line directly(DC) or indirectly(AC, DC/AC). Breaking is achieved by blending control which is the proportional combination between regenerative breaking of VVVF inverter and air pressure control of breaking operating unit(BOU). Therefore, Data obtained during two operation are very important items to evaluate the running performance of RS. This paper has investigated in real time data acquired from VVVF inverter and measured by pressure sensor directly connected to air breaking line(motor car and trailer car). By analyzing data in the region of time and frequency, fundamental methods for eavaluating the running performance of RS quantitatively and objectively have been suggested.

  • PDF

On the Model Tests for POD Propulsion Ships

  • Go Seokcheon;Seo Heungwon;Chang Bong Jun
    • Journal of Ship and Ocean Technology
    • /
    • v.9 no.1
    • /
    • pp.1-10
    • /
    • 2005
  • The procedures of model test and performance prediction for the CRP-POD propulsion ships, are studied. At the CRP-POD system, which are highly applicable to ultra large container carriers, RPM ratio of two propellers is not fixed, unlike conventional CRP system, and hence the power of each propeller must be predicted respectively. In this paper, a CRP-POD system is designed for 10,000 TEU class ultra large container carriers, and the characteristics of the CRP-POD system are experimentally studied. Finally, based on this study, the procedure of powering performance evaluation for CRP-POD propulsion ships is suggested. However, further studies on quantitative correction of the present procedure are required.

Correlation Analysis of Model Tests with Ship Powering Data for a 60,000 DWT Bulk Carrier (6만 DWT 산적화물선(散積貨物船) 모형선-실선(模型船-實船) 상관해석(相關解析))

  • Seung-Il,Yang;Chang-Sup,Lee;Eun-Chan,Kim
    • Bulletin of the Society of Naval Architects of Korea
    • /
    • v.19 no.4
    • /
    • pp.61-70
    • /
    • 1982
  • The hydrodynamic effects on resistance and propulsive performance were studied by using the data from model test and full scale speed trials. A series of model tests on 3 geosims for a 60,000 DWT Bulk Carrier was conducted at KIMM's Ship Experimental Towing Tank and the results analyzed by 1978 ITTC Performance Prediction Method show the correlation between 3 geosim models. Also powering data of full scale speed trials were analyzed by the newly developed computer program and the correlation analysis between ship and model was studied.

  • PDF

Efficient Driving Pattern of the Railway Vehicles for Driving Energy Saving (주행에너지 절약을 위한 철도차량의 효율적 열차주행 패턴)

  • Kim, Jung-Hyun;Shin, Han-Chul;Choi, Yung-Ho;Han, Soo-Hee;Kim, Lark-Kyo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.9
    • /
    • pp.1368-1373
    • /
    • 2012
  • In this paper, we propose an efficient driving pattern which consumes less energy for driving from one station to next. Three driving patterns for four sections in the No. 5 subway line of Seoul Metropolitan Rapid Transit Corp. are compared for the energy consumption, the maximum speed, and the powering time. It turns out that the powering time and the maximum speed should be decreased as much as possible in order to achieve the efficient driving.

A Three-Phase Line-Interactive UPS System to Eliminate the Inrush Current Phenomenon during Switching-in of an Auxiliary Load while Powering the Main Load

  • Bukhari, Syed Sabir Hussain;Ayub, Muhammad;Kwon, Byung-il
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.4
    • /
    • pp.1623-1630
    • /
    • 2018
  • Normally, various auxiliary loads are installed along with the main load in industrial applications. Usually, load transformers are used to convey such types of auxiliary loads. The transformers become energized when the loads are turned-on, consequently, high amplitude of inrush current appears at the output of the uninterrupted power supply (UPS) system. To mitigate these high current amplitudes, this manuscript suggests a three-phase line-interactive UPS system to counter the inrush current during the turning-on of the auxiliary load transformer while powering the main load by using a current controlled inverter. Experimental results of a laboratory-sized prototype are provided in the support of the proposed UPS system for validation.

An Analysis about Consumed Energy of Electric Multiple Unit Used TCMS Data on the Condition of Safety Driving (안전운행 조건하에서 TCMS 데이터를 활용한 전동차 주행에너지 해석)

  • Kim, Kyujoong;Lee, Keunoh;An, Sukwan
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.6
    • /
    • pp.31-42
    • /
    • 2012
  • Urban transit vehicle that uses electrical energy, is faster, safer and energy-efficient public transit than other means. As a Research method, the Matlab/Simulink are used to modeling a regenerative brake-capable train, and actual parameters such as powering and braking characteristics, all kinds of resistance, passenger load, velocity, gradient, radius of curve etc and powering and breaking commands per time or distance are inputted to train's dynamic equation, then a simulation program is made and used to yield train driving pattern and driving time and the amount of driving energy used thereby at auto and manual operation and at all sector.

Development of Independent 1 kW-class PEMFC-Battery Hybrid System for a Building (건물용 독립형 1kW급 PEMFC-배터리 하이브리드 시스템 기술 개발)

  • Yang, Seug Ran;Kim, Jung Suk;Choi, Mi Hwa
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.5 no.2
    • /
    • pp.113-120
    • /
    • 2019
  • We have developed 1 kW-class PEMFC-battery hybrid system independently powering to the building, through the process of system design, current load characteristics analysis, power system configuration for demonstration site and performance evaluation. In order to use the fuel cell and battery as the hybrid type, a control technology for the charging/discharging decision and charging speed of the battery is required rather than using fuel cell. Also output power distribution between PEMFC and the battery is a core of energy management technology. It is confirmed that it is possible to supply independently 1kW powering the building to ensure optimal energy management through the power control experiment of the hybrid system.

A Design of Low-power/Small-area Arithmetic Units for Mobile 3D Graphic Accelerator (휴대형 3D 그래픽 가속기를 위한 저전력/저면적 산술 연산기 회로 설계)

  • Kim Chay-Hyeun;Shin Kyung-Wook
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.5
    • /
    • pp.857-864
    • /
    • 2006
  • This paper describes a design of low-power/small-area arithmetic circuits which are vector processing unit powering nit, divider unit and square-root unit for mobile 3D graphic accelerator. To achieve area-efficient and low-power implementation that is an essential consideration for mobile environment, the fixed-point f[mat of 16.16 is adopted instead of conventional floating-point format. The vector processing unit is designed using redundant binary(RB) arithmetic. As a result, it can operate 30% faster and obtained gate count reduction of 10%, compared to the conventional methods which consist of four multipliers and three adders. The powering nit, divider unit and square-root nit are based on logarithm number system. The binary-to-logarithm converter is designed using combinational logic based on six-region approximation method. So, the powering mit, divider unit and square-root unit reduce gate count when compared with lookup table implementation.