• Title/Summary/Keyword: PowerPC

Search Result 1,058, Processing Time 0.04 seconds

Evolutionary game theory-based power control for uplink NOMA

  • Riaz, Sidra;Kim, Jihwan;Park, Unsang
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.12 no.6
    • /
    • pp.2697-2710
    • /
    • 2018
  • Owing to the development of Internet of Things (IoT), the fifth-generation (5G) wireless communication is going to foresee a substantial increase of mobile traffic demand. Energy efficiency and spectral efficiency are the challenges in a 5G network. Non-orthogonal multiple access (NOMA) is a promising technique to increase the system efficiency by adaptive power control (PC) in a 5G network. This paper proposes an efficient PC scheme based on evolutionary game theory (EGT) model for uplink power-domain NOMA system. The proposed PC scheme allows users to adaptively adjusts their transmit power level in order to improve their payoffs or throughput which results in an increase of the system efficiency. In order to separate the user signals, a successive interference cancellation (SIC) receiver installed at the base station (BS) site. The simulation results demonstrate that the proposed EGT-based PC scheme outperforms the traditional game theory-based PC schemes and orthogonal multiple access (OMA) in terms of energy efficiency and spectral efficiency.

A survey for the structure of I/O system applied for the PC-based DCS (PC 기반 분산제어시스템의 입출력시스템 구조에 관한 고찰)

  • Lee, Chan-Ju;Kim, Eung-Seok
    • Proceedings of the KIEE Conference
    • /
    • 1999.07b
    • /
    • pp.877-879
    • /
    • 1999
  • 최근 윈도우즈 기반 운영체제의 발전과 PC의 성능 향상으로 제어분야에서의 PC 활용이 가속화되면서 PC 기반의 분산제어시스템이 등장하였고, 전력연구원에서는 화력발전소의 국산개발 배연탈황설비 제어시스템에 PC 기반 분산제어시스템을 도입하여 운용하고 있다. 이러한 PC 기반 분산제어시스템의 활용으로 하위구조에 다양한 종류의 입출력시스템을 선택 가능하게 되었고 시스템 구축에 대한 독자적인 방법을 채택할 수 있게 되었다. 본 논문에서는 국산개발 배연탈황설비에 적용된 PC 기반 분산제어시스템의 전반적인 구성을 살펴보고 제어프로세서인 현장제어유닛과 하위 입출력시스템의 하드웨어 구조, 상호간 통신 구조 및 시스템 이중화구조에 대하여 기술하고자 한다. 또한 입출력시스템 간의 인터페이스 방법과 입출력 모듈 종류에 따른 현장기기의 활용방법에 대하여 알아보고 향후 PC 기반 분산제어시스템의 입출력시스템 구축 시 고려하여야 할 사항들에 대하여 기술하고자 한다.

  • PDF

Adaptive Channel Attenuation Compensation Scheme for Minimum PAR in Satellite OFDMA Downlink (위성 OFDMA Downlink에서 PAR을 최소화 하기 위한 사용자 부채널 할당 및 채널 보상 기법)

  • Kim, Han-Nah;Choi, Kwon-Hue;Ahn, Do-Seob;Kang, Kun-Seok;Kim, Hee-Wook
    • Journal of Satellite, Information and Communications
    • /
    • v.4 no.1
    • /
    • pp.28-35
    • /
    • 2009
  • We investigate the adaptive channel attenuation compensation of satellite OFDMA downlink users for minimum PAR (Peak to Average power Ratio), which is one of the main challenging issues in satellite OFDMA application. First, we analyze and compare PAR performances of two main different channel attenuation compensation schemes for OFDMA, i.e., PC-OFDMA (power control OFDMA) and AMC-OFDMA (Adaptive Modulation and Coding). While AMC-OFDMA maintains the constant transmission powers through entire user data subcarriers, PC-OFDMA has non-uniform subcarrier transmission powers because subcarrier powers are separately controlled to compensate each user's sub-channel attenuation. We newly found the fact that non-uniform subcarrier power in PC-OFDMA achieves rather reduced PAR compared to AMC-OFDMA and the amount of reduction becomes larger as the power differences among subcarriers increase. Also, there is an additional PAR reduction in PC-OFDMA by optimizing subcarrier grouping scheme for user's sub-channelization.

  • PDF

Control of Parallel Operation for PV PCS (대용량 태양광 발전 시스템의 병렬운전 기법)

  • Kim, Kyutae;Kwon, Jungmin
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.49.2-49.2
    • /
    • 2011
  • 본 논문에서는 대용량 태양광 PCS의 병렬운전 알고리즘에 대해 제안한다. 제안한 알고리즘은 dc-link 전압을 이용하여 PCS를 독립적으로 제어한다. 일반적으로 태양광 PCS는 정격용량 또는 그 근처에서 최대 효율을 낸다. 제안한 알고리즘은 일사량이 적을 시 일부 PCS만 작동하도록 하여 전력 변환 효율을 높인다. 항상 모든 PCS가 작동하는 것이 아니라 필요한 수량만 작동하도록 하고, 작동하는 PCS도 순차적으로 바꿔서, 전제 시스템의 수명을 늘리는 효과도 있다. 또한 일부 PCS가 고장이 날 경우 다른 PCS가 작동하도록 하여 태양광 발전이 멈추지 않고 계속 발전할 수 있도록 한다.

  • PDF

The Effect of Electroacupuncture at the PC6(Naegwan) and TE5 (Oegwan) on the EEG (내관, 외관 전침 자극이 뇌파변화에 미치는 영향)

  • Yim, Jin-Teck;Kim, Su-Hyun;Lee, Sang-Ryong
    • Journal of Pharmacopuncture
    • /
    • v.6 no.3
    • /
    • pp.91-106
    • /
    • 2003
  • Objectives : The aim of this study was to examine the effects of electroacupuncture(EA) at the PC6(Naegwan) and the TE5 (Oegwan) on nounal humans using power spectral analysis. Methods : EEG power spectrum exhibit site-specific and state-related differences in specific frequency bands. In this study, power spectrum was used as a measure of complexity. 30 channel EEG study was carried out in 30 subjects(30 males ; age=23.7 years). Results : In ${\alpha}$(alpha) band, the power values at F7 channels(p<0.05) during the PC6-acupoint treatment were significantly were decreased. In ${\beta}$(beta) band, the power values at Fp1, Fz, TT1, T5, P3, P4, Po1, P02, O1, Oz, O2 channels(p<0.05) during the non-acupoint treatment and at Fp1, F4, F8 channels(p<0.05) during the TE5-acupoint treatment significantly were increased. In ${\theta}$(theta) band, the power values at Fp1 channels(p<0.05) during the non-acupoint treatment and at Oz channels(p<0.05) the TE5-acupoint treatment significantly were increased. but, the power values at F7 channels(p<0.05) during the non-acupoint treatment were significantly were decreased. In ${\delta}$(delta) band, the power values at TCP1, TCP2, CP1, T5 channels(p<0.05) during PC6-acupoint treatment were increased and the power values at F7, TT2 channels(p<0.05) during non-acupoint treatment were increased. but, the power values at the TE5-acupoint treatment significantly was decreased than the before-acupuncture treatment.

Statistical Comparison of ULF wave Power of Magnetic field between the upstream solar wind and the magnetosheath: THEMIS observations

  • Park, Mi-Young;Kim, Hee-Jeong;Lee, Dae-Young;Kim, Kyung-Chan
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.1
    • /
    • pp.96.2-96.2
    • /
    • 2012
  • We statistically examined ULF Pc 3-5 wave power in the regions of undisturbed upstream solar wind, quasi-parallel shock (and foreshock), quasi-perpendicular shock, and the magnetosheath to understand how and to what extent the wave power changes as the solar wind propagates to the magnetosheath. For this study, we used the magnetic field data from the THEMIS spacecraft and Wind (as shifted to the bow shock nose) for May-November in 2008 and 2009. The statistical results show that, in the case of the Pc5 wave power, the sheath power is roughly proportional to the upstream power for both quasi-parallel (and foreshock) and quasi-perpendicular shock regions. Also we identified undisturbed upstream condition from WIND as being well away from foreshock region, and found that the sheath power can be larger for quasi-parallel shock region by a factor of 5-15 than for quasi-perpendicular shock region. In the cases of Pc 3 and Pc4 waves, we found the higher sheath power when associated with the foreshock than with the quasi-perpendicular shock region.

  • PDF

Study of Dynamic Engineering Simulator for Oxy-PC Power Plant (Oxy-PC 발전 플랜트용 Dynamic Engineering Simulator 개발에 관한 고찰)

  • Yu, Kwang-Myung;Kim, Jong-An
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1848-1849
    • /
    • 2011
  • Oxy-PC 발전시스템은 화석 연료를 연소하는 과정에서 발생하는 다량의 이산화탄소를 회수처리 하기위해 고려되고 있는 방법 중 하나이며, 신규 발전 시스템은 물론이며 기존 발전시스템에도 개조 과정을 거쳐 적용이 용이한 장점이 있다. 하지만 현재 국내에 해당 시스템의 적용 사례는 없을 뿐만 아니라 설계 기술의 확보도 부족한 실정이다. 따라서 순산소 연소 시 발생하는 복합적인 문제를 사전에 예측하고 시스템 구현 과정에서 발생되는 시행착오를 최소화하기 위해서는 순산소 연소 공정모델을 반영한 Dynamic Engineering Simulator 개발이 요구된다. 본 논문에서는 Oxy-PC 발전 시스템의 특징을 기존 공기 연소 발전 시스템과 비교하여 설명하고 Oxy-PC 발전 플랜트용 Dynamic Engineering Simulator 개발 절차에 대해 기술한다.

  • PDF

Development of Network based Green Power Management System (친환경 네트워크 기반 소비전력 관리시스템 개발)

  • Kim, Ju-Hee;Rhee, In-Baum;Yoon, Chi-Woong;Ryu, Dae-Hyun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2011.10a
    • /
    • pp.779-781
    • /
    • 2011
  • In this paper, we developed Network based Green Power Management System which is consist of EMS, Smart Plug, PC Agent and SmartPhone App. for power saving of PC and a varity of peripheral devices in office or home, and we evaluated the perfornance of our system.

  • PDF

A Stand-alone hybrid distributed power system example based on the Photovoltaic Power System for DC power supply (직류전원 공급용 태양광 발전 시스템 기반 독립형 하이브리드 분산전원 시스템 일례)

  • Yoon, Yeo-Young;Kim, Hong-Sung;Choi, Jaeho
    • Proceedings of the KIPE Conference
    • /
    • 2015.11a
    • /
    • pp.117-118
    • /
    • 2015
  • 본 연구에서는 독립형 직류 배전망 구성에 이용될 수 있는 태양광 발전 시스템 및 ESS(Energy Storage System)를 이용한 하이브리드형 분산 전원 시스템의 구성 일례를 제시한다. 제안된 시스템의 전력회로는 태양광 발전 시스템용 PCS에는 직렬 공진 탱크를 가지는 절연형 풀브리지 방식, ESS용 PCS에는 비절연형 양방향 컨버터로 구성되었다. 태양광 PCS의 제어방식으로는 전류 제어기가 사용되었으며, ESS 용 PCS에는 비집중식 제어방식이 적용 되었다. 제안된 방식의 타당성을 검증하기 위해 100[kW]급 태양광 시스템, 100[kW]급 ESS를 기반으로 하이브리드 시스템을 구현하고 직류 계통 전압 제어 특성, 부하급변에 대한 전력분담 제어 실험결과를 제시하였다.

  • PDF

T2PC: Temperature-aware Transmission Power Control Scheme for Wireless Sensor Networks (무선 센서 네트워크를 위한 온도인지형 전송파워 제어 기법)

  • Lee, Jung-Wook;Chung, Kwang-Sue
    • Journal of KIISE:Information Networking
    • /
    • v.37 no.5
    • /
    • pp.403-408
    • /
    • 2010
  • The sensor nodes can be installed in the environment in which the temperature change is considerable, such as desert, urban, and data center. Particularly, because the output power becomes less than the targeted power if a temperature is increasing, link quality is degraded and packet losses are occurred. In order to compensate the temperature changes, existing schemes detect the change of the link quality between nodes and control transmission power through a series of feedback process. However, these approaches can cause heavy overhead by additional control packets. In this paper, we propose the T2PC(Temperature-aware Transmission Power Control) to keep up the link quality despite temperature variation. At each node, T2PC compensates the attenuated link quality by controlling the transmission power based on the local temperature measurement. In addition, the packet reception ratio can be improved with less control packets than ones required in existing transmission power control methods based on the feedback control.