• 제목/요약/키워드: Power-to-mass ratio

검색결과 237건 처리시간 0.028초

원심형 공기압축기 성능시험 (Performance Test for a Centrifugal Air Compressor)

  • 신유환;안이기;김광호;손병진
    • 대한기계학회논문집
    • /
    • 제19권8호
    • /
    • pp.1964-1971
    • /
    • 1995
  • In the present study, the performance characteristics of a centrifugal air compressor were investigated experimentally. The PC controlled performance test facility for a centrifugal air compressor driven by an electric motor with a gear box to achieve higher compressor rotating speed was set up in the present study. The performance test for a turbocharger compressor of a diesel engine was conducted, and in a case of 34,800 rpm, pressure ratio 1.18, flow rate 0.09kg/s, compressor efficiency 61% were investigated. Adiabatic power for a tested compressor showed maximum value at mass flow ratio 0.8. The value of mass flow ratio of maximum efficiency was about 0.37, it was independent of compressor rotating speed.

유한요소해석 기반 원전 기계구조물 충격-질량지표 개발 (Development of FEA-based Metal Sphere Signal Map for Nuclear Power Plant Structure)

  • 문성인;강토;한순우
    • 한국압력기기공학회 논문집
    • /
    • 제14권1호
    • /
    • pp.38-47
    • /
    • 2018
  • For safe operation of nuclear power plants, a loose-part monitoring system (LPMS) is used to detect and locate loose-parts within the reactor coolant system, and to estimate their mass and damage potential. There are several methods to estimate mass, such as the center frequency method based on the Hertz's impact theory, a frequency ratio method and so on, but it is known that these methods cannot provide accurate information on impact response for identifying the impact source. Thanks to increasing computing power, finite element analysis (FEA) method recently become an available option to calculate reliably impact response behavior. In this paper, a finite element analysis model to simulate the propagation behavior of the bending wave, generated by a metal ball impact, is validated by performing a series of impact tests and the corresponding finite element analyses for flat plate and shell structures. Also, a FEA-based metal sphere signal map is developed, and then blind tests are performed to verify the map. This study provides an accurate simulation method for predicting the metal impact behavior and for building a metal sphere signal map, which can be used to estimate the mass of loose-parts on site in nuclear power plants.

암모니아-물 작동유체의 부분증발유동을 적용한 재생 랭킨사이클에 관한 연구 (Study on Regenerative Rankine Cycle with Partial-Boiling Flow Using Ammonia-Water Mixture as Working Fluid)

  • 김경훈
    • 설비공학논문집
    • /
    • 제23권3호
    • /
    • pp.223-230
    • /
    • 2011
  • The power cycle using ammonia-water mixture as a working fluid is a possible way to improve efficiency of the system of low-temperature source. In this work thermodynamic performance of the ammonia-water regenerative Rankine cycle with partial-boiling flow is analyzed for purpose of extracting maximum power from the source. Effects of the system parameters such as mass fraction of ammonia, turbine inlet pressure or ratio of partial-boiling flow on the system are parametrically investigated. Results show that the power output increases with the mass fraction of ammonia but has a maximum value with respect to the turbine inlet pressure, and is able to reach 22 kW per unit mass flow rate of source air at $180^{\circ}C$.

Vibration control of a stay cable with a rotary electromagnetic inertial mass damper

  • Wang, Zhi Hao;Xu, Yan Wei;Gao, Hui;Chen, Zheng Qing;Xu, Kai;Zhao, Shun Bo
    • Smart Structures and Systems
    • /
    • 제23권6호
    • /
    • pp.627-639
    • /
    • 2019
  • Passive control may not provide enough damping for a stay cable since the control devices are often restricted to a low location level. In order to enhance control performance of conventional passive dampers, a new type of damper integrated with a rotary electromagnetic damper providing variable damping force and a flywheel serving as an inertial mass, called the rotary electromagnetic inertial mass damper (REIMD), is presented for suppressing the cable vibrations in this paper. The mechanical model of the REIMD is theoretically derived according to generation mechanisms of the damping force and the inertial force, and further validated by performance tests. General dynamic characteristics of an idealized taut cable with a REIMD installed close to the cable end are theoretically investigated, and parametric analysis are then conducted to investigate the effects of inertial mass and damping coefficient on vibration control performance. Finally, vibration control tests on a scaled cable model with a REIMD are performed to further verify mitigation performance through the first two modal additional damping ratios of the cable. Both the theoretical and experimental results show that control performance of the cable with the REIMD are much better than those of conventional passive viscous dampers, which mainly attributes to the increment of the damper displacement due to the inertial mass induced negative stiffness effects of the REIMD. Moreover, it is concluded that both inertial mass and damping coefficient of an optimum REIMD will decrease with the increase of the mode order of the cable, and oversize inertial mass may lead to negative effect on the control performance.

전자기 및 기계적 특성을 고려한 다중 적층형 AFPMSG의 설계 (Design of Multi-stack Axial Flux Permanent Magnet Synchronous Generator Considering Electromagnetic and Mechanical Characteristics)

  • 사이드 쿼반알리샤;유용민;권병일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.1043-1044
    • /
    • 2011
  • This paper discusses the electromagnetic and mechanical design considerations to improve the design accuracy and power to mass ratio of multi-stack axial flux permanent magnet synchronous generator (AFPMSG). Design accuracy of multi-stack AFPMSG for direct drive wind turbine application is improved by considering magnetic flux leakages and fringing effect. FEM structural analysis is utilized to increase power to mass ratio of three-stack AFPMSG by reducing the rotor yoke thickness considering magnetic and centrifugal forces and Von Mises stress distribution.

  • PDF

외팔보 형태의 수동형 Multiple Tuned Mass Damper를 이용한 구조물의 진동 억제 (The Suppression of Structural Vibration Using Cantilevers as Multiple Tuned Mass Damper)

  • 박재관;백윤수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1996년도 춘계학술대회논문집; 부산수산대학교, 10 May 1996
    • /
    • pp.169-176
    • /
    • 1996
  • In order to suppress the structural vibration more effectively, Multiple Tuned Mass Damper(MTMD) which is composed of a number of Tuned Mass Damper(TMD) can be used. Especially, the passive MTMD has several advantages over active TMD like easy installment and maintenance, cost and performance for power failure situation(severe damage of power lines from earthquake), etc.. For this purpose the mass and damping ratio of MTMD and the distributed frequency range which shows the range of MTMD's distribution are used as main design parameters. When the passive MTMD is constituted with multiple cantilevers, the facility in its real production and its need for only a smaller space can be named as its several advantages. In this study, the satisfactory results were obtained from the composition of MTMD utilizing dynamic characters of cantilevers, and the verification was done by the comparison of the analysis from MTMD with the computer simulation.

  • PDF

저유량 고비속도 원심압축기 임펠러에서의 팁간극에 따른 효과 (Tip Clearance Effect of Low Mass Flow Rate High Specific Speed Centrifugal Impeller)

  • 임강수;김양구;김귀순
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.240-243
    • /
    • 2008
  • In this paper, the design of Centrifugal Compressor which is used in sizes 50 horse power has 8 pressure ratio and numerical analysis of the flow within compressor varying tip clearance length are performed. To get high pressure ratio with low power the exit height of impellers is low but compressor has very high speed of revolution. So compressor has high specific speed although mass flow rate is very small. The shape of impellers at the first stage is carried out. Flow and performance characteristics of impellers has been analyzed by using a commercial CFD program, $Fine^{TM}$/turbo. The result shows that loss coefficient is affected by tip clearance length and compressor has proper tip clearance length. It is possible to decrease loss by selecting apt tip clearance length.

  • PDF

LNG 냉열을 이용하는 동력사이클 열역학 해석 (Thermodynamic Analysis of Power Generation Cycle Utilizing LNG Cold Energy)

  • 최권일;장홍일
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제1권1호
    • /
    • pp.48-55
    • /
    • 1999
  • thermodynamic cycle analysis has been performed for the power generation systems to utilize the cold energy of liquefied natural gas (LNG). The power cycle used the air or water at room temperature as a heat source and the LNG at cryogenic temperature as a heat sink. Among manypossible configurations of the cycle. the open Rankine cycle. and the closed Brayton cycle, and the closed Rankine cycle are selected for the basic analysis because of their practical importance. The power output per unit mass of LNG has been analytically calculated for various design parameters such as the pressure ratio. the mass flow rate. the adiabatic efficiency. the heat exchanger effectiveness. or the working fluid. The optimal conditions for the parameters are presented to maximize the power output and the design considerations are discussed. It is concluded that the open Rankine cycle is the most recormmendable both in thermodynamic efficency and in practice.

  • PDF

CO2를 작동유체로 하는 가스터빈의 성능예측 (Performance Prediction of a Gas Turbine Using CO2 as Working Fluid)

  • 양현준;강도원;이종준;김동섭
    • 한국유체기계학회 논문집
    • /
    • 제14권2호
    • /
    • pp.41-46
    • /
    • 2011
  • This study investigated the changes in performance and operating characteristics of an F-class gas turbine according to the change of working fluid from air to carbon dioxide. The revised gas turbine is the topping cycle of the semi-closed oxy-fuel combustion combined cycle. With the same turbine inlet temperature, the $CO_2$ gas turbine is expected to produce about 85% more power. The main contributor is the greater compressor mass flow and the added oxygen flow for the combustion. Compressor pressure ratio increases about 50%. However, the gas turbine efficiency reduces about 10 %. Modulation of inlet guide vane to reduce the compressor inlet mass flow, the major purpose of which is to reduce the compressor inlet Mach number, was also performed.

다중동조질량감쇠기를 이용한 단순지지 슬래브의 진동 및 소음저감에 관한 연구 (Vibration and Noise Control of the Simply Supported Slab Using the Multi-tuned Mass Damper)

  • 황재승;홍건호;박홍근
    • 한국소음진동공학회논문집
    • /
    • 제18권10호
    • /
    • pp.1006-1013
    • /
    • 2008
  • In this study, it is outlined that heavy weight floor impact noise induced by the vibration of slab can be reduced using multi tuned mass damper(MTMD) effectively. Substructure synthesis is utilized to develope analytical model of the slab coupled with MTMD and acoustic power is introduced to evaluate the performance of noise control for simplicity. Numerical analysis is carried out to investigate the effect of the properties of MTMD on the vibration and noise control of the simply supported slab. Numerical analysis shows that mass ratio of MTMD is critical on the vibration and noise control of the slab and it is also essential to reduce the vibration in higher modes of slab in the light of its great effect on the radiation of sound.