• Title/Summary/Keyword: Power-on Effect

Search Result 8,619, Processing Time 0.035 seconds

여성의류 유통경로에서 의존성.권력원천.갈등 - 백화점 입점업체를 중심으로

  • 정현주
    • Journal of Distribution Research
    • /
    • v.3 no.1
    • /
    • pp.123-143
    • /
    • 1998
  • The aim of this paper is to investigate the women's apparel distribution channel in the well-known department stores located in the central Seoul area. Since the department store has its reputation, information and enormous buying power, it is the one of the major leading retails in the women's apparel industry. In doing so, the relationship between the channel members in terms of the level of dependence, power sources and perceived conflict and manifest conflict has been studied. Particularly, based on French and Raven's power sources, position source is added. It refers to a channel member's (Merchandizer in the department store) source over another based on the expection the former (Merchandizer in the department store) will be able to allocate the location and size of the store influencing the latter's sale and profit. The key informants are the merchandizers who work in the apparel companies contracting with major department stores. Finally, of the 284 questionnaires collected, 235 are usable. The hypotheses are tested through LISREL. The results of statistical analysis support that : Dependence has a positive effect on noncoercive bases of power. Coercive bases of power have a positive effect on manifest conflict as well as perceived conflict while noncoercive bases of power have a negative effect mainly on manifest conflict. Thus, the relation between the major department stores and the women's apparel companies in there seems to have bilateral dependence rather than highly unilateral dependence.

  • PDF

A Study on Machining Effects on Residual Stress at Dissimilar Metal Weld Region (기계가공이 이종용접부의 잔류응력에 미치는 영향에 관한 연구)

  • Lee, Kyoung-Soo;Lee, Jeong-Geun;Lee, Seong-Ho;Park, Chi-Yong;Lee, Seung-Geon;Park, Jai-Hak
    • Journal of Welding and Joining
    • /
    • v.29 no.2
    • /
    • pp.56-63
    • /
    • 2011
  • his paper aimed to understand the residual stress in the dissimilar metal welds of nuclear power plant. Two kinds of residual stress were considered, which caused by welding and machining. Residual stress due to mechanical machining was measured by hole-drilling technique and x-ray diffraction method for the SA508 and F316L. Weld residual stress at dissimilar metal weld between SA508 and F316L was evaluated by FEA. Residual stress profiles were obtained for the inside surface and through thickness of welds. Machining effect was also analyzed by FEA. According to the residual stress measurement, it was observed that mechanical machining can generate tensile stress on the surface of the test material. However, FEA results showed that mechanical machining did not increase the tensile stress on the surface of weld region. Further study with more elaborate measurement and numerical analysis is required to identify the effect of machining on residual stress in the dissimilar metal weld region.

Primary Restoration Path Selection Considering Ferranti Effect and Reactive Power Capability of Black-start Generators

  • Park, Ji-Man;Lee, Heung-Jae;Yu, Won-Kun;Jang, Byung-Tae;Lee, Kyeong-Seob
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.1377-1382
    • /
    • 2015
  • Power system restoration following a massive blackout starts with re-energizing Primary Restorative Transmission (PRT) systems at first. As power systems have been gradually enlarged and become more complex, periodical evaluation and reassignment of PRTs are needed. So far it has been decided by try and error approach by corresponding human experts to analyze and evaluate them. This paper presents an intelligent system that finds optimal primary restoration paths using analytic and heuristic knowledge from PSS/E data, and suggests an optimal PRTs depending on the condition of Ferranti effect or a reactive power capability margin of black-start generator. This system was tested in Korea Electric Power system, and showed a promising result.

An Analysis on Possibility and Effect of Market Power under the 3rd Long Term Power Plan (제3차 전력수급기본계획에 따른 시장지배력 행사가능성 및 영향분석)

  • Lee, Jae-Gul;Park, Min-Hyuk;Ahn, Nam-Sung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.6
    • /
    • pp.1017-1022
    • /
    • 2007
  • In this paper, we try to analyze the likelihood of exercising the power of market dominance by certain generators in future power industry of Korea. Firstly, we estimated installed generation capacity and sales volume of electricity in Korea, based on 'The 3rd Long Term Power Plan' which was announced in December 2006. Secondly, we calculated HHI, an index showing the degree of concentration of an industry, and RSI, an index showing how adequate the supply of goods or services of an industry is, using Fast-Forward. Thirdly, assuming a major generator employs the strategy of withholding a part of its available capacity at a peak time, we simulated hypothetical movement of SMP over a certain period of time, which is compared with that obtained without assuming such strategy to generate Lerner Index. an index showing the degree of market power of a monopoly. Regulators, home and abroad, have not given much interest in analyzing the effect of market dominance that is likely to be exercised by certain players in the future. That said, this paper provides insight into developing methodologies of analyzing and mitigating such effect by proposing the above indices to gauge it. In addition, this paper also shows the potential impact of employing capacity withholding strategy on the financial account of a dominant generator.

Geometric structure and electronic behavior of Rh decorating effect on zigzag CNTs (n=7-12): A DFT study

  • Cui, Hao;Zhang, Xiaoxing;Zhou, Yongjian;Zhang, Jun
    • Carbon letters
    • /
    • v.26
    • /
    • pp.61-65
    • /
    • 2018
  • Comprehensive calculations of the Rh decoration effect on zigzag CNTs with n ranging from 7 to 12 were conducted in this work to understand the effect of Rh doping on geometric structures and electronic behaviors upon metallic and semiconducting CNTs. The obtained results indicated that Rh dopant not only contributes to the deformation of C-C bonds on the sidewall of CNTs, but also transforms the electron distribution of related complexes, thereby leading to a remarkable increase of the conductivity of pure CNTs given the emerged novel state within the energy gap for metallic CNTs and the narrowed energy gap for semiconducting CNTs. Our calculations will be meaningful for exploiting novel CNT-based materials with better sensitivity to electrons and higher electrical conductivity compared with pure CNTs.

The Effect of a Kinesio Taping on Muscle Power and Fatigue Index in Quadriceps femoris (넙다리네갈래근의 키네시오 테이핑 적용이 근파워 및 근피로에 미치는 영향)

  • Seo, Byoung-Do;Jung, Nam-Jin;Park, Sang-Wok;Oh, So-Hyeon;Woo, Ji-In;Kim, Ju-Hyun;Ahn, Seong-Min
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.17 no.1
    • /
    • pp.29-34
    • /
    • 2011
  • Background: The purpose of this study was to investigate the effect of a Kinesio taping on muscle power and fatigue index in quadriceps femoris (vastus medialis, vastus lateralis, rectus femoris.). Methods: 15 male (heathy collegiate students) was enrolled from Kyungwoon university, Gumi. Kinesio tape was applied on quadriceps femoris muscle of subjects. Muscle power and fatigue index was measured by Wingate ergometer (warm-up was 30sec in 60W, maximum power test was 30sec in 100W, recovery was 30sec in 60W) in pre- and post applied taping. Results: As a results, there showed statistically significant improvement in mean power, peak power, mean power/kg, peak power/kg, fatigue index (p<.05). Conclusions: The study of Wingate test by applying Kinesio taping was significantly effected in mean power, peak power, mean power/kg, peak power/kg.

  • PDF

Effect of the Interconnected Solar Power Generation System on the Power Quality of Power System (계통연계형 태양광발전 시스템이 계통의 전력품질에 미치는 영향)

  • Kwon, Dong-Chul;Park, Joong-Sin;Yi, Dong-Young
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.7
    • /
    • pp.52-58
    • /
    • 2012
  • In this study, we have investigated the effect of the solar power generation facilities on the power quality of interconnected solar power generation system. When the solar power generation facility was connected to the distribution system, whether the solar power generation is under operation or not, Peak factor of current was increased to 0.033[%], Frequency is deviated from $60{\pm}0.2$[Hz] and also Short term flicker indication($P_{st}$) increased to 0.213[p.u.] compare with the disconnected situation. Harmonic current [%] in orders was 11.42[%] maximum under 11th orders and was 7.861[%] between 11th and 17th orders. These values were about 3 or 4 times compared with "the power system interconnection technique standards" at the same situation above. Therefore, we could confirmed that the solar power generation facility, when it was connected to the existing distribution system, made bad influence on the power qualities such as the peak factor of current, frequency regulation, short term flicker indication($P_{st}$) and harmonic current [%] in orders etc.

Effect of Dispersion Stability of Particles on Detergency of Particulate Soil(Part 1) - The Dispersion Stability of α-Fe2O3 Particles in the Nonyl Phenol Polyoxyethylene Ether Solution - (입자의 분산안정성이 고형오구의 세척성에 미치는 영향(제1보) - Nonyl Phenol Polyoxyethylene Ether 용액 내에서 α-Fe2O3 입자의 분산안정성 -)

  • Kang, In-Sook
    • Fashion & Textile Research Journal
    • /
    • v.4 no.1
    • /
    • pp.86-91
    • /
    • 2002
  • To estimate dispersion stability of particles, suspending power and particle size were examined as functions of pHs, surfactants, electrolytes and ionic strengths using ${\alpha}-Fe_2O_3$ particle as the model of particulate soil. Suspending power and particle size were determined by UV-Vis spectrumeter and by light scattering using the polarization ratio method, respectively. The suspending power was relatively high with polyanion electrolytes and was low with neutral salts. The suspending power was biphasis, minimum pH 6~7, and the effect of surfactant on the suspending power was insignificant. Generally suspending power increased with decreasing the particle size governed aggregation of dispersed particles regardless of solution conditions. Hence the suspending power was inversely related to the particle size.

Electrodeposition of Copper on Porous Reticular Cathode (II) - Effect of PEG and MPS on throwing Power- (다공성 그물구조 음극을 이용한 구리 전착에 관한 연구 (II) -유기첨가제 PEG, MPS의 영향 -)

  • Lee Kwan Hyi;Lee Hwa Young;Jeung Won Young
    • Journal of the Korean Electrochemical Society
    • /
    • v.4 no.2
    • /
    • pp.41-46
    • /
    • 2001
  • The effect of organic additives such as PEG ind MPS on throwing power have been studied in the fabrication of porous reticular metal by electrodeposition using the mixture of cupric sulfate and sulfuric acid as electrolyte. Both the polarization test and the electrodeposition on the stacked electrodes, mean pore diameter of which was $250{\mu}m$, were performed to illustrate the behavior of throwing power quantitatively. As far as PEG was concerned, it lowered throwing power of electrodeposition on the porous electrode used in this work while the addition of MPS up to 500 ppm in electrolyte enhanced throwing power monotonously. When both MPS and PEG were added in electrolyte, the effect of MPS on throwing power was superior to that of PEG. However, the excess addition of MPS was found to cause the defect in mechanical strength of deposit layer. From the result of SEM observation, it could be concluded that less than 50 ppm of MPS in electrolyte was appropriate to avoid the breakage of deposit layer.

A Comparative Study on the Bus Voltage Control Effect of STATCOM and UPFC in Power Flow Analysis of Power Systems (전력계통의 조류해석에서 STATCOM과 UPFC의 모선전압 제어효과에 대한 비교연구)

  • 김덕영;국경수
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.5
    • /
    • pp.41-45
    • /
    • 2001
  • This paper presents an comparative study on the effect of STATCOM and UPFC to power flow analysis of power systems. The effect of STATCOM can be analyzed with PSS/E program which is generally used in power system analysis, while UPFC model for power flow analysis is not provided yet. Thus, UPFC is equivalently represented as a synchronous condenser and load, while the active and reactive power of the specific transmission line and the voltage of the bus is controlled appropriately. This procedure is implemented by IPLAN which is an external macro program of PSS/E. The simulation results show that UPFC is more effective to control the bus voltage than STATCOM, because UPFC can control not only the bus voltage where the parallel inverter is installed but also the active and reactive power flow in the transmission line where the series inverter is installed.

  • PDF