• Title/Summary/Keyword: Power-Saving System

Search Result 652, Processing Time 0.025 seconds

An analysis on power regeneration of hydrostatic pressure exchanger (정수압방식 동력회수장치의 구동동력 절감량 해석)

  • Ham, Y.B.;Choi, J.H.;Jeong, H.S.;Park, S.J.;Park, J.H.;Yun, S.N.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.4 no.3
    • /
    • pp.7-12
    • /
    • 2007
  • This paper presents an energy saving hydrostatic pressure exchanger for sea water desalination equipment. In a reverse osmosis(RO) system for desalinating sea water, more than 70 percent of the supplied sea water, brines which were impassable through RO membrane are bypassed, resulting in high energy losses. In this paper, a hydrostatic pressure exchanger consisting of an embedded water hydraulic piston motor and a water hydraulic piston pump was proposed and investigated in order to recover the energy of the bypassed brines. The pressurized brines are supplied to the embedded water hydraulic piston motor as power sources and the water hydraulic piston pump is driven by the output torque of the embedded water hydraulic piston motor as well as electric motor. Consequently, the energy of the bypassed brines can be recovered. To examine the electric energy saving characteristics of the hydrostatic pressure exchanger, a simulation model was constructed using commercial software and experiments were conducted. Through the results of simulation and experiment, the feasibility of the electric energy saving effect of the proposed hydrostatic pressure exchanger was investigated.

  • PDF

A Development of Intelligent Metering and Control System for Energy Management of Electric Cabinet Panel (분전반 전력관리용 지능형 계측 제어 시스템 개발)

  • Park, Byung-Chul;Park, Jae-Sung;Song, Sung-Kun;Shin, Joong-Rin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.8
    • /
    • pp.90-97
    • /
    • 2013
  • In recent years, the many electric saving methods are studied because of difficulty of meeting the demand. The electric energy management such as monitoring of branch power consumption, demand control, metering, power quality monitoring, electric safety monitoring can make energy saving. The purpose of this paper is to develop a system which can provide the integrated management of various functions required for energy management by consumers. In this system all functions which were embodied into each devices are integrated into intelligent meter. The developed systems are tested and implemented by installing at consumer electric distribution panel.

Analysis of Performance and Economical Efficiency through Cycle Simulation for Power Saving BIP(Block Ice Plant) (절전형 제빙시설 사이클 모사를 통한 성능 및 경제성 해석)

  • 강종호;김남진;이재용;김종보
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.6
    • /
    • pp.455-461
    • /
    • 2001
  • Domestic ice making companies make effort to obtain products and neglect to introduce low cost product improvements with energy savings. The work presented here is an implementation of ice making method to improve both energy efficiency and productivity. In this present investigation, several ice making cycles are proposed for higher efficiency in the system. COP(Coefficient of Performance), ice making time and electric energy consumption are evaluated and compared with the conventional system. Results shows that COP is improved with more efficient use of time for ice making and electric consumption. Therefore, this can offer an opportunity for more efficient use of energy and higher productivity in ice making.

  • PDF

Energy Saving Components Analysis in Hybrid Desiccant Dehumidification System (하이브리드 데시칸트 제습방식 에너지 절감 요소분석)

  • Park, Jongil;Park, Seungtae
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.11
    • /
    • pp.603-608
    • /
    • 2015
  • The hybrid desiccant dehumidifier is an energy-effective system in comparison with the existing desiccant dehumidifier. Its main feature is to use the heat given off by the condenser as the react heat source. Through analysis of the elements for a more efficient design of the hybrid desiccant dehumidifier, it is evident that those energy-saving components do not work individually, but organically influence the efficiency of the equipment. Therefore, the hybrid desiccant dehumidifier may be an important product in the dehumidification industry.

Performence Characteristics and Analysis Effect of Maximum Power Saving Device in Metal Parts Heat Treatment Company (금속 부품 열처리업체의 최대전력절감장치 동작 특성 및 효과 분석)

  • Chang, Hong-Soon;Han, Young-Sub;Hwang, Ik-Hwan;Seo, Sang-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.6
    • /
    • pp.40-44
    • /
    • 2014
  • In this paper, maximum power is the lowering device using the facility's energy use and peak load electricity through analyzing attitude should like to make it reduce its power base rate. Simulator to manage the demand for power, a maximum electric power base power from electronic watt-hour meters by a device's signal, predictive power, the current power by computing the goal of power for less than Maximum peak power and peak shift, so that you can manage, and peak York, which role you want a cut Metal heat treatment result which analyzes the data, demand for electricity company over the years of analyzing the characteristics of each load, and effects and Reducing power consumption device every month identified seven Sequence control to the load system and successful power control is about showing that the defined goals.

Development of Power Energy Management System for Ships including Energy Saving of Separated Load Systems (개별 부하 시스템의 에너지 절감을 포함한 선박 전력 에너지 관리 시스템 개발)

  • Kang, Young-Min;Oh, Jin-Seok
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.1
    • /
    • pp.131-139
    • /
    • 2018
  • Many ship researches have been carried out in connection with the fourth revolution, one of which focuses on EMS(energy management system). The EMS is referred to as systems for managing the energy of ships and include various systems. In this paper, we analyze the energy saving field in ship and propose a ship power energy management system including individual load control systems that can save energy in the engine room. EMS includes individual load control systems of PCS (Pump Control System), ERFCS (Engine Room Fan Control System), LCS (Load Control System), HVACS (Heating, Ventilation, Air conditioning Control System). Proposed EMS primarily conserves energy in the individual load systems of the engine room. Secondly, the integrated monitoring and control system is used to control the power generation system and the power load system to save energy.

Human Visual System-Aware Optimal Power-Saving Color Transformation for Mobile OLED Devices (모바일 OLED 디스플레이를 위한 인간 시각 만족의 최적 전력 절감 색 변환)

  • Lee, Jae-Hyeok;Kim, Eun-Sil;Kim, Young-Jin
    • Journal of KIISE
    • /
    • v.43 no.1
    • /
    • pp.126-134
    • /
    • 2016
  • Due to the merits of OLED displays such as fast responsiveness, wide view angle, and power efficiency, their use has increased. However, despite the power efficiency of OLED displays, the portion of their power consumption among the total power consumption is still high since user interaction-based applications such as instant messaging, video play, and games are frequently used. Their power consumption varies significantly depending on the display contents and thus color transformation is one of the low-power techniques used in OLED displays. Prior low-power color transformation techniques have not been rigorously studied in terms of satisfaction of the human visual system, and have not considered optimal visual satisfaction and power consumption at the same time in relation to color transformation. In this paper, we propose a novel low-power color transformation technique which strictly considers human visual system-awareness as well as optimization of both visual satisfaction and power consumption in a balanced way. Experimental results show that the proposed technique achieves better human visual satisfaction in terms of visuality and also shows on average 13.4% and 22.4% improvement over a prior one in terms of power saving.

Reliability Modeling of Direct Current Power Feeding Systems for Green Data Center

  • Choi, Jung Yul
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.4
    • /
    • pp.704-711
    • /
    • 2013
  • Data center is an information hub and resource for information-centric society. Since data center houses hundreds to ten thousands servers, networking and communication equipment, and supporting systems energy saving is one of the hottest issues for green data center. Among several solutions for green data center this paper introduces higher voltage direct current (DC) power feeding system. Contrary to legacy alternating current (AC) power feeding system equipped with Uninterruptible Power Supply (UPS), higher voltage DC power feeding system is reported to be a more energy efficient and reliable solution for green data center thanks to less AC/DC and DC/AC conversions. Main focus of this paper is on reliability issue for reliable and continuous operation of higher voltage DC power feeding system. We present different types of configuration of the power feeding systems according to the level of reliability. We analyze the reliability of the power feeding systems based on M/M/1/N+1/N+1 queueing model. Operation of the power feeding system in case of failure is also presented.

Sequential Hypothesis Testing based Polling Interval Adaptation in Wireless Sensor Networks for IoT Applications

  • Lee, Sungryoul
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.11 no.3
    • /
    • pp.1393-1405
    • /
    • 2017
  • It is well known that duty-cycling control by dynamically adjusting the polling interval according to the traffic loads can effectively achieve power saving in wireless sensor networks. Thus, there has been a significant research effort in developing polling interval adaptation schemes. Especially, Dynamic Low Power Listening (DLPL) scheme is one of the most widely adopted open-looping polling interval adaptation techniques in wireless sensor networks. In DLPL scheme, if consecutive idle (busy) samplings reach a given fixed threshold, the polling interval is increased (decreased). However, due to the trial-and-error based approach, it may significantly deteriorate the system performance depending on given threshold parameters. In this paper, we propose a novel DLPL scheme, called SDL (Sequential hypothesis testing based Dynamic LPL), which employs sequential hypothesis testing to decide whether to change the polling interval conforming to various traffic conditions. Simulation results show that SDL achieves substantial power saving over state-of-the-art DLPL schemes.

LSTM-based Power Load Prediction System Design for Store Energy Saving (매장 에너지 절감을 위한 LSTM 기반의 전력부하 예측 시스템 설계)

  • Choi, Jongseok;Shin, Yongtae
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.14 no.4
    • /
    • pp.307-313
    • /
    • 2021
  • Most of the stores of small business owners are those that use a large number of electrical devices, and in particular, there are many stores that use a cold storage system. In severe cases, there is a lot of power load on the store, which can cause a loss to the assets in the store as the power supply is cut off. Accordingly, in this paper, an LSTM-based power load prediction system was designed to measure the energy demand rate of stores and to save energy. Since it can be used as a data-based power saving system for small and medium-sized stores, it is expected to be used as a data-based power demand prediction system for small businesses in the future, and to be used in the field of preventing damage due to power load.