Development of CVTs Composed of a 2K-H I Type Differential Gear Unit and a V-belt Drive (2K-H형 I 형식 차동기어장치와 V-belt 전동장치를 결합한 무단변속기의 개발)

  • Kim, Yeon-Su;Choi, Sang-Hoon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.6
    • /
    • pp.1060-1068
    • /
    • 2002
  • Compound continuously variable transmission(CVT) mechanisms are proposed, which can offer a backward mode, a geared neutral, an underdrive mode and an overdrive mode. They are composed of a 2K-H I type differential gear unit, a V-belt type continuously variable unit(CVU), a few friction clutches and gears, and not required of a starting device as a torque converter. Compound CVT mechanisms developed here present two distinct operating modes which are a power circulation mode and a power split mode. The transition of two modes takes place at the particular CVU speed ratio. For these CVT mechanisms, performance analysis related to speed ratio, power ratio and efficiency are executed and proven by experimental studies.

A development of Local Unit's diagnosis algorithm for power transformer (변압기용 Local Unit의 진단알고리즘 개발)

  • Choi, I.S.;Kim, M.H.;Lee, J.C.
    • Proceedings of the KIEE Conference
    • /
    • 2008.11a
    • /
    • pp.336-338
    • /
    • 2008
  • 송변전기기는 고압 대용량화로 진행되어, 기기의 고장 발생 시 그 파급효과는 엄청나다. 이에 전력설비들은 매우 높은 신뢰성이 요구되며 특히 기기의 고장을 예측 진단하여 신뢰성을 높이는 부분은 필수 불가결한 부분이 되었다. 이에 (주)효성에서는 변압기 진단을 위한 센서 및 IED가 포함된 지능형 변압기(Intelligent Power Transformer)용 Local Unit을 개발하였다. 본 논문은 (주)효성에서 개발한 Local Unit의 진단알고리즘에 대해 기술하였다.

  • PDF

Commercial Vehicle Anti-Start Air Conditioner Compressor System Using a Power Conversion Unit (전력변환장치를 이용한 상용차용 무시동 에어컨 압축기 시스템)

  • Han, Keun-Woo;Kim, Seong-Gon;Lee, Chung-Hoon;Choi, Myoung-Hyun;Jung, Young-Gook;Lim, Young-Cheol
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.6
    • /
    • pp.96-108
    • /
    • 2015
  • his study deals with a power conversion unit of an anti-start air conditioner compressor system for the commercial vehicle. In case of converter, to reduce the switching losses and current stresses of the device, applies LLC resonant topology. Transformer leakage inductance in the full-bridge converter is used for making the resonance with the capacitor of the voltage-doubler. Through this method we can increase power and decrease volume of system. Both circuit analysis and design guideline are described. So in this paper, power conversion unit is designed. 2.5kW anti-start air conditioner compressor system was implemented, and system operation and stability was verified through experiment.

Relative Power Density Distribution Calculations of the Kori Unit 1 Pressurized Water Reactor with Full-Scope Explicit Modeling of Monte Carlo Simulation

  • Kim, Jong-Oh;Kim, Jong-Kyung
    • Nuclear Engineering and Technology
    • /
    • v.29 no.5
    • /
    • pp.375-384
    • /
    • 1997
  • Relative power density distributions of the Kori Unit 1 pressurized water reactor are calculated by Monte Carlo modeling with the MCNP code. The Kori Unit 1 core is modeled on a three-dimensional representation of the one-eighth of the reactor in-vessel component with reflective boundaries at 0 and 45 degrees. The axial core model is based on half core symmetry and is divided into four axial segments. Fission reaction density in each rod is calculated by following 100 cycles with 5,000 test neutrons in each cycle after starling with a localized neutron source and ten noncontributing settle cycles. Relative assembly power distributions are calculated from fission reaction densities of rods in assembly. After 100 cycle calculations, the system converges to a k value of 1.00039 $\geq$ 0.00084. Relative assembly power distribution is nearly the same with that of the Kori Unit 1 FSAR. Applicability of the full-scope Monte Carlo simulation in the power distribution calculation is examined by the relative root moan square error of 2.159%.

  • PDF

A Solar Array Shunt Switching Unit Considering Worst Case Analysis (최악조건을 고려한 태양전지 어레이 션트 전압조절기)

  • Choi Jae-Dong
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.10 no.4
    • /
    • pp.403-410
    • /
    • 2005
  • This Paper Presents development of solar may shunt switching unit with a fully regulated Power regulation for Geostationary Earth Orbit(GEO) satellite. This shunt switching unit comprises the solar may shunt modules that regulate the solar array power. These solar array shunt modules connect/disconnect the solar array segments to/from the bus through switching actions. And that is also possible simply extension to an existing design by FPGA control logic changing. In order to verify the proposed design, the control logic and worst case analysis are analyzed and the simulation and experimental results we shown.

A Fully Digital Controlled Fly-back Single Stage Power Supply Unit for the Wireless Dimming System of LED Lightings

  • Oh, Yongseung;In, Chigak;Cho, Kyumin
    • Journal of Advanced Information Technology and Convergence
    • /
    • v.9 no.2
    • /
    • pp.75-87
    • /
    • 2019
  • This paper presents a fully digital controlled power supply unit for the wireless controlled dimmable LED lighting system. The proposed power supply designed using a fly-back converter, which is directly controlled by a microprocessor. Although the proposed circuit does not sense the AC input current and has not AC input voltage feed-forward, it can achieve a high power factor. The proposed power supply directly regulates the output power for LED loads using the PWM and PFM control of the fly-back converter without additional regulator. For a wireless remote control function, the Zigbee modem is equipped in the proposed power supply. A prototype set-up has been built and tested. Through the experiment with a prototype set-up, the usefulness of the proposed power supply is verified.

Low-Power Systolic Array Viterbi Decoder Implementation With A Clock-gating Method (Clock-gating 방법을 사용한 저전력 시스톨릭 어레이 비터비 복호기 구현)

  • Ryu Je-Hyuk;Cho Jun-Dong
    • The KIPS Transactions:PartA
    • /
    • v.12A no.1 s.91
    • /
    • pp.1-6
    • /
    • 2005
  • This paper presents a new algorithm on low power survivor path memory implementation of the trace-back systolic array Viterbi algorithm. A novel idea is to reuse the already-generated trace-back routes to reduce the number of trace-back operations. And the spurious switching activity of the trace-back unit is reduced by making use of a clock gating method. Using the SYNOPSYS power estimation tool, DesignPower, our experimental result shows the average $40{\%}$ power reduction and $23{\%}$ area increase against the trace-back unit introduced in [1].

A Study on the Design of Small Unit SCADA System for Electric Railroad (전기철도용 소규모SCADA 시스템 설계방안에 관한 연구)

  • Lee, Seung-Chul;Shin, Kwan-Woo;Lee, Youn-Seop
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.53 no.2
    • /
    • pp.89-93
    • /
    • 2004
  • Supervisory Control And Data Acquisition(SCADA) of electric power system refersto the system that displays, monitors and executes the control commands for remote electric power system. KNR's existing electric power control system is built on UNIX platform such that it costs more for system construction, and people with UNIX skills can only be an operator who controls and manages the system. Moreover, since the system is mainly operated in local offices, system operators must communicate with local operators to investigate the cause of the accident and react the accident every time the system fails. As a new integrated SCADA system is constructed, establishment of small-unit electric power control system, that alters local electric power control system in designated stations, is required. In this study, the electric power control system, which accommodates all functions of UNIX-based SCADA system and facilitates operation and even maintenance for local operators, is to be developed. In order to develop small-unit electric power control system, the industrial automation program, "Cimon", is used. The small-unit electric power control system that accommodatesRTU and newly installed electronic switchboard is being developed and tested at Chulam station of KNR.

Development of UPS System Embedded in Computer Power Supply Using GUI (GUI를 이용한 컴퓨터 Power Supply 내장형 UPS 시스템의 개발)

  • Roh, Inh-Bae;Park, Jee-Ho;Hwang, Gi-Hyun;Kim, Dong-Wan;Woo, Jung-In
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.53 no.4
    • /
    • pp.190-194
    • /
    • 2004
  • In this paper, UPS, which is embedded in computer power supply, is developed against the poor utility power system. In the developed system, PIC16C54 is used as the main controller, and UPS system consists of micom control module, power failure detecting module, charging module, power module, synchronous transfer module, and GUI module. Additionally, GUI module consists of battery charging state unit, power operating unit and operating state unit. The effectiveness of the developed system has been verified by the experimental results.

A development of Local Unit for intelligent power transformer (Intelligent Power Transformer용 Local Unit 개발 사례)

  • Choi, I.S.;Kim, M.H.;Yang, H.J.;Lee, J.C.;Hong, J.K.
    • Proceedings of the KIEE Conference
    • /
    • 2007.11b
    • /
    • pp.220-222
    • /
    • 2007
  • 자연재해 및 전력 시스템의 복잡성, 외부 노출 등으로 인해 전력 설비는 언제나 고장에 노출되어 있다. 전력회사는 전력의 안정성과 신뢰도 확보를 위해 끊임없이 노력하고 있지만 전력설비의 자그마한 이상에도 그 파급효과는 상당히 클 수 있다. 이에 선진 국가와 기업에서는 전력설비의 예방진단에 대한 많은 관심과 기술 개발이 이루어지고 있으며, 제품화되어 출시되고 있는 실정이다. (주)효성에서는 변압기 진단을 위한 센서 및 IED가 포함된 지능형 변압기(Intelligent Power Transformer)용 Local Unit을 개발하였다.

  • PDF