• 제목/요약/키워드: Power unbalance

검색결과 389건 처리시간 0.024초

운전조건병경에 의한 미분탄화력의 미연분 저감 (Reduction of unburned carbon derived from coal-fired power plant by changing operating conditions)

  • 박호영;김영주;유근실;김춘근;김동훈
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2006년도 제33회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.299-303
    • /
    • 2006
  • From the analysis of fly ash, which contains unburned carbon, collected from the coal-fired Yong Hung power station, most particles are turned out to be hollow cenosphere and agglomerated soot particles. The sooting potential from six coals used in the plant were investigated with CPD model. The results show that the higher potential presented to Peabody, Arthur, Shenhua coals rather than other coals. It is necessary to measure the coal flow rates at each coal feeding pipe for four burner levels since they affect the extent of mixing of soot with oxidant, in turn, the oxidation rate of soot particles. The unbalance in coal flow rate was found in several coal pipes. We successfully reduced unburned carbon in ash by increasing the excess air and changing the SOFA yaw angle.

  • PDF

분산전원이 연계된 배전계통에서 ULTC와 분산전원의 전압제어 (Voltage Control of ULTC and Distributed Generations in Distribution System)

  • 전재근;원동준;김태현
    • 전기학회논문지
    • /
    • 제60권12호
    • /
    • pp.2206-2214
    • /
    • 2011
  • LDC(Line Drop Compensation) is widely used in controlling ULTC(Under Load Tap Changer) output voltage at distribution substation. However, LDC may experience some difficulties in voltage control due to renewable energy resources and distributed generations. Therefore, more advanced voltage control algorithm is necessary to deal with these problems. In this paper, a modified voltage control algorithm for ULTC and DG is suggested. ULTC is operated with the voltages measured at various points in distribution system and prevents overvoltage and undervoltage in the distribution feeders. Reactive power controller in DG compensates the voltage drop in each distribution feeders. By these algorithms, the voltage unbalance between feeders and voltage limit violation will be reduced and the voltage profile in each feeder will become more flat.

3상 4 스위치 Z-소스 PWM정류기의 출력전압과 역률에 관한 연구 (A Study On the Output Voltage and Power Factor of the Three-Phase Four Switches Z-Source PWM Rectifier)

  • 수효동;엄준현;정영국;임영철
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2013년도 추계학술대회 논문집
    • /
    • pp.48-49
    • /
    • 2013
  • In this paper, the four switches three-phase Z-source rectifier is studied. The conventional three-phase four switches rectifier can only either perform buck or boost operation, distortion and unbalance of the input current are serious. Therefore, we proposed the four switches three-phase Z-source rectifier which can realize buck function simply by applying the Z-impedance network. We will verify characteristics of Z-network by the simulation and experiment.

  • PDF

테이퍼 결합구조를 갖는 4$\times$4 성형 결합기에 관한 연구 (A Study on Silica based 4$\times$4 Optical Star Coupler with Tapered Coupling Structure)

  • 윤현성;김정근
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1998년도 추계종합학술대회 논문집
    • /
    • pp.983-986
    • /
    • 1998
  • Inthis paper, we design 4$\times$4 optical star coupler with tapered coupling structure. The 4$\times$4 optical star coupler consists of four 3dB couplers and a 100% coupler with tapered structure. This star coupler is designed by the 2 dimension FD-BPM(finite difference beam propagation method) using TBC(transparent boundary condition). consequently, the maximum power unbalance ratios of relative output power from each of the output waveguides for each of input guides are less than 0.1dB, and the transmission efficiency is more than 99%.

  • PDF

차단전압 균형과 넓은 부하범위를 갖는 새로운 3-레벨 ZVS PWM DC-DC 컨버터 (A Novel Three-Level ZVS PWM Inverter Topology for High-Voltage DC/DC Conversion Systems with Balanced Voltage Sharing and Wider Load Range)

  • 송인호;유상봉;서범석;현동석
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1996년도 창립기념 전력전자학술발표회 논문집
    • /
    • pp.71-75
    • /
    • 1996
  • As the Three-level ZVS PWM DC-DC converter operates likewise full-bridge ZVS PWM DC-DC converter and the blocking voltage of each switching device is a half of the DC-link voltage, it is suitable for the high imput voltage applications. However, it has some problems as follows; The blocking voltage of each devices is unbalanced and it causes the power losses of the inner switching devices to be increased. Also, it has narrow load range so that the switching losses and the efficiency are reduced as it goes to the light load. This paper presents an nove Three-level ZVS PWM DC-DC converter, which can reduce the overvoltage of the outer switches, eliminate the unbalance of the voltage sharing between the switches at turn-off due to the stray inductances, and operate from no load to full load. The characteristics and the performances of the proposed Three-level ZVS PWM DC-DC converter are verified by simulation and experimental results

  • PDF

최적주입방식에 의한 3상 전류형 능동필터의 운전특성 (Three-Phase Current-Fed Active Power Filter Operating Characteristics by Optimized Injection Method)

  • 박수영;김호진;이정민;황정호;최규하
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 하계학술대회 논문집
    • /
    • pp.451-455
    • /
    • 1991
  • The PWM control technique is proposed which can eliminate the harmonic components of the nonsinusoidal ac line current such as the current of 6-phase rectifier by injecting PWM current. TSC(Time-Sharing Control) is adopted to avoid the unbalance between three PWM injection currents at the three-phase system. Also a new power circuit for three-phase filter is suggested for realizing the proposed PWM control technique. The operation characteristics are investigated theoretically and experimentally to show the feasibility of the optimized injection method.

  • PDF

능동필터 겸용 무정전 전원장치 (Parallel processing of an active filter and a UPS)

  • 강유리;김원호;김종수;임근희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 A
    • /
    • pp.550-552
    • /
    • 1994
  • Recently, various activ filters such as current type and voltage type have been proposed to suppress harmonics caused by nonlinear load due to the use of semiconductor switching devices. At the early stage, active filters are used only to suppress harmonics. However, it has been proposed that they offer more functions such as voltage regulations, improvements of power factor and 3 phase unbalance. This study presents a combined function of active filter and a UPSs with one power processing stage.

  • PDF

Mitigation of Voltage Unbalances in Bipolar DC Microgrids Using Three-Port Multidirectional DC-DC Converters

  • Ahmadi, Taha;Rokrok, Esmaeel;Hamzeh, Mohsen
    • Journal of Power Electronics
    • /
    • 제18권4호
    • /
    • pp.1223-1234
    • /
    • 2018
  • In this paper, a new three-port multidirectional DC-DC converter is proposed for integrating an energy storage system (ESS) to a bipolar DC microgrid (BPDCMG). The proposed converter provides a voltage-balancing function for the BPDCMG and adjusts the charge of the ESS. Thanks to the multi-functional operation of the proposed converter, the conversion stages of the system are reduced. In addition, the efficiency and weight of the system are improved. Therefore, this converter has a significant capability when it comes to use in portable BPDCMGs such as electric DC ships. The converter modes are analyzed and small-signal models of the converter in each of the independent modes are extracted. Finally, comprehensive simulation studies are carried out and a BPDCMG laboratory prototype is implemented in order to verify the performance of the proposed voltage balancer using the burst mode control scheme.

Study on PWM Converter Control under Unbalanced Network Condition

  • Sastrowijoyo, Fajar;Choi, Jaeho
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2011년도 전력전자학술대회
    • /
    • pp.524-526
    • /
    • 2011
  • This paper focuses on study on PWM converter control under unbalanced network condition. Voltage unbalance in a three-phase system causes the performance deterioration by producing 120 Hz voltage ripples in the DC link and 120 Hz ripple in reactive power. To eliminate the ripples, both positive and negative sequence currents should be controlled simultaneously. In this paper four PI controllers on synchronous reference frame is implemented to control D and Q currents in both positive and negative sequence. Positive and negative sequence signal extraction is done using delay signal cancellation method. Simulation results show satisfactory performance in suppressing 120 Hz ripples.

  • PDF

초퍼저항 및 de-loading 협조제어를 통한 해상풍력 연계용 HVDC시스템 DC전압 상승 억제 방안 (DC Voltage Build-Up Suppression Scheme of HVDC System for Offshore Wind Farm Connection using Chopper Resistor and de-loading)

  • 이형진;강병욱;김재철
    • 전기학회논문지
    • /
    • 제66권5호
    • /
    • pp.750-756
    • /
    • 2017
  • This paper presents a method for DC voltage control of HVDC system connection of offshore wind farms. In the event of fault in AC grid, HVDC system need to meet LVRT regulations. When HVDC system meet LVRT regulation, unbalance is caused between power input and power output for DC link. Therefore, LVRT regulation lead to DC voltage increase of HVDC system. To control the DC voltage increase, the chopper resistor can be suggested. In this paper, DC voltage suppression is proposed using chopper resistor and de-loading. The effectiveness of the chopper resistor was verified using PSCAD/EMTDC.