• Title/Summary/Keyword: Power system interconnection

Search Result 206, Processing Time 0.033 seconds

50KW Photovoltaic Generation System for Model House Power Supply Using Alternative Energy (대체에너지 이용 시범주택 전원용 50KW 태양광발전시스템)

  • Park, J.M.;Park, J.H.;Kim, K.B.;Lee, K.Y.;Shin, S.H.;Cho, G.B.;Baek, H.N.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.1335-1337
    • /
    • 2002
  • This paper presents experimental operation with utility interactive 50kw photovoltaic generation system. And that describe configuration of utility interactive photovoltaic system which power supply for dormitory. The status of photovoltaic generation system components and interconnection and safety equipment will be summarized. This paper discusses property operation state which system endure division of power for dormitory.

  • PDF

Efficiency characteristics analysis of residential PV System (주택용 태양광발전시스템의 성능비교 분석)

  • LEE K. Y.;CHOI Y. O.;BAEK H. L.;CHO G. B.;Lee S. G.;KIM D. H.
    • Proceedings of the KIPE Conference
    • /
    • 2004.07a
    • /
    • pp.144-146
    • /
    • 2004
  • This paper presents experimental operation with utility invertactive 3kW photovoltaic generation system. And that describe configuration of utility interactive photovoltaic system which power supply for Demonstration experiment. The status of photovoltaic generation system comp-onents and interconnection and safety equipment will be summarized. This paper discusses property operation state which system endure division of power for demonstration experiment.

  • PDF

Operating Characteristics of Photovoltaics System for Chosen University Dormitory (조선대학교 기숙사 전원용 PV 시스템의 운전특성)

  • Park J.M.;Choi Y.O.;Lee K.Y.;Oh G.G.;Cho G.B.
    • Proceedings of the KIPE Conference
    • /
    • 2006.06a
    • /
    • pp.564-566
    • /
    • 2006
  • This paper presents experimental operation with utility interactive 50kW photovoltaic generation system. And that describe configuration of utility interactive photovoltaic system which power supply for dormitory. The status of photovoltaic generation system components and interconnection and safety equipment will be summarized. This paper discusses property operation state which system endure division of power for dormitory.

  • PDF

Using Demonstration PV System for Operation Efficiency Analysis (태양광발전시스템의 실증연구를 통한 운용효율 분석)

  • Park Jeong Min;Kim Seong Kyeol;Jung Byung Ho;Cho Geum-Bae;Baek Hyung Rae
    • Proceedings of the KIPE Conference
    • /
    • 2003.11a
    • /
    • pp.244-246
    • /
    • 2003
  • This paper presents experimental operation with utility invertactive 3kW photovoltaic generation system. And that describe configuration of utility interactive photovoltaic system which power supply for Demonstration Complex. The status of photovoltaic generation system components and interconnection and safety equipment will be summarized. This paper discusses property operation state which system endure division of power for Demonstration Complex.

  • PDF

Demonstration analysis of residential 3kW PV System (주택보급형 3kW PV시스템 실증연구)

  • Park, J.M.;Moon, Y.A.;Kim, H.S.;Lim, B.O.;Baek, H.L.
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.734-736
    • /
    • 2005
  • This paper presents experimental operation with utility invertactive 3kW photovoltaic generation system. And that describe configuration of utility interactive photovoltaic system which power supply for Demonstration experiment. The status of photovoltaic generation system comp-onents and interconnection and safety equipment will be summarized. This paper discusses property operation state which system endure division of power for demonstration experiment.

  • PDF

The Power Quality about Wind/Diesel combined power generation in isolated area (고립지역의 풍력/디젤 복합발전 전력품질 특성)

  • Ko, Seok-Whan;Kim, Seok-Woo;Lee, Youn-Seop
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.245-249
    • /
    • 2009
  • Antarctic King Sejong Station was established in King George Island, the South Pole in 1988, and has been executing the monitoring studies on the change of antarctic natural environment. As an available power, the wind energy generator has been used in the form of hybrid with mainly diesel generator. Because the wind generation power sharply changes by wind energy, it must be careful during the system operation. When the power system becomes stable, the output performance of wind energy generator becomes stable. But, in case of unstable system, the errors frequently occur on the wind energy generator and it badly impacts the power system by output of wind energy generator. The purpose of this paper is to analyze suitability while operating the system of 10kW wind energy generator at Antarctic King Sejong Station, an isolated area, and to analyze the problem and improvements by power quality.

  • PDF

Bit-Rate Analysis of Various Symmetric ESQWs SEED under Optimized Input Power (최적 입사 광 전력 하에서의 대칭 ESQWs SEED의 비트 전송률 특성 분석)

  • Lim, Youn-Sup;Choi, Young-Wan
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.36D no.7
    • /
    • pp.66-79
    • /
    • 1999
  • We investigate the effects of high input power on the performance of optical bistable symmetric self-electooptic effect devices (S-SEEDs) using extremely shallow quantum wells (ESQWs). In this study, we consider the four ESQWs SEEDs; anti-reflection (AR)-coated ESQWs S-SEED, back-to-back AR coated ESQWs S-SEED, asymmetric F뮤교-Perot (AFP) ESQWs S-SEED, and back-to-back AFP-ESQWs S-SEED. As the input power increases, device performances such as on/off contrast ratio, on/off reflectivity difference are seriously degraded because of ohmic heating and exciton saturation. On the other hand, switching speed of the device increases up to certain value and then begins to decrease. With reasonable optimization of the input power for the best switching speed operation of the devices in a cascading optical interconnection system, we simulate and analyze the system bit-rate of the various ESQWs S-SEEDs, for a mesa of $5{\times}5{\mu}m^2$ size, changing the namber of quantum wells for the external bias of 0 V and -5V.

  • PDF

Evaluation of Optimal Transfer Capability in Power System Interconnection (연계된 계통간의 최적 송전 용량 산정)

  • Son, Hyun-Il;Bae, In-Su;Jeon, Dong-Hoon;Kim, Jin-O
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.4
    • /
    • pp.679-685
    • /
    • 2010
  • As the electrical power industry is restructured, the electrical power exchange is becoming extended. One of the key information used to determine how much power can be transferred through the network is known as available transfer capability (ATC). To calculate ATC, traditional deterministic approach is based on the severest case, but the approach has the complexity of procedure. Therefore, novel approach for ATC calculation is proposed using cost-optimization method, well-being method and risk-benefit method in this paper. This paper proposes the optimal transfer capability of HVDC system between mainland and a separated island in Korea through these three methods. These methods will consider production cost, wheeling charge through HVDC system and outage cost with one depth (N-1 contingency).

Evaluation of Optimal Transfer Capability in Power System interconnection (연계된 계통간의 최적 송전용량 산정)

  • Son, Hyun-Il;Choi, Ah-Reum;Lee, Sung-Hoon;Kim, Jin-O;Jeon, Dong-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.195_196
    • /
    • 2009
  • As the electrical power industry is restructured, the electrical power exchange is becoming extended. One of the key information used to determine how much power can be transferred through the network is known as available transfer capability (ATC). To calculate ATC, traditional deterministic approach is based on the severest case, but the approach has the complexity of procedure. Therefore, novel approach for ATC calculation is proposed using cost-optimization method in this paper, and is compared with well-being method and risk-benefit method. This paper proposes the optimal transfer capability of HVDC system between mainland and a separated island in Korea through these three methods. These methods will consider production cost, wheeling charge through HVDC system and outage cost with one depth (N-1 contingency).

  • PDF

Demonstration Research of 3kW Solar Tracking PV System (3kW 추적형 태양광발전시스템의 실증연구)

  • Choi Y.O.;Kim J.H.;Bian W.J.;Lee S.Y.;Cho G.B.
    • Proceedings of the KIPE Conference
    • /
    • 2006.06a
    • /
    • pp.561-563
    • /
    • 2006
  • This paper summarizes the results of these efforts by offering the PV generation system with solar tracking. The status of PV generation system with solar tracking components and interconnection and effects are semmarized. Hence this paper duscusses only points that might be useful for application.

  • PDF