• Title/Summary/Keyword: Power ratio

Search Result 6,492, Processing Time 0.031 seconds

PERFORMANCE OF AN OSCILLATING SUBSOILER IN BREAKIN HARD PAN

  • Bandalan, E.P.;Gupta, C.P.;Salokhe, V.M.;Niyamapa, T.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1993.10a
    • /
    • pp.1043-1052
    • /
    • 1993
  • Field experiments were conducted to determine the optimum combination of performance parameters of a single-shank, tractor-mounted oscillating subsoiler. Tests were conducted at frequencies of oscillation of 3.7 , 5.67, 7.58, 9.48 and 11.456Hz ; amplitudes of 18, 21, 23.5, 34 and 36.5 mm ; and forward speeds of 1.84, 2.19 and 3.42 kmph at moisture content close to the plastic limit of the soil. It was observed that there was a reduction in average draft but an a increase in average total power requirement for oscillating than non-oscillating subsoiling. The draft and power ratios were significantly affected by the forward speed, frequency and amplitude. Their combined interaction expressed in terms of the velocity ratio parameter( the ratio of peak tool velocity and forward speed) however has the strongest influence. At the same velocity ratio, the draft reduction and power increase were less at higher amplitude of oscillation . As the oscillating frequency is increased toward the soil resonance the draft requirement becomes less. For the field conditions tested. the optimum operation was obtained at an amplitude of 36.5mm, frequency of 9.48Hz and speed of 2.19 kmph with a draft ratio of 0.33 and a power ratio of only 1.24.

  • PDF

Temperature and Power Generation Characteristics of c-Si G/G Spandrel Window depending on Opening Ratio of PV Module (스팬드럴용 투광형 결정계 PV창호의 셀 간격 개구율에 따른 온도 및 발전성능 해석연구)

  • Yoon, Jong-Ho;Kim, Dong-Su;Oh, Myung-Hwan;Lee, Jae-Beom
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.4
    • /
    • pp.51-58
    • /
    • 2012
  • This study aims to analyze characteristics of Cell surface temperature and generated power performance for improving PV(Photovoltaic) system condition according to the cell opening ratio of transparent crystal PV system at Spandrel of curtain-wall. For this purpose, alternatives were classified for eight different cases that opening ratio of transparent crystal PV system varied from 0% to 70%, which was used by simulation tool, EnergyPlus. As results, it turned out that increasing opening ratio of transparent crystal PV system led higher PV surface temperature, back-sheet type was thus the most advantageous for decreasing surface temperature, annual generating efficiency, and annual accumulated generating power. Consequently, blocking off air space from outside insolation can advantageously keep to be better condition for generated power performance.

Dynamic Characteristics of Automatic Transmission System Due to the Change of Planetary Gear Ratio (자동변속기내 유성기어비 변화에 의한 동력전달계의 동적특성)

  • 박영일;김영석
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.15 no.10
    • /
    • pp.120-127
    • /
    • 1998
  • In this study the dynamic characteristics of automatic transmission system due to the change of the planetary gear ratio is studied. To study the power flow and shift quality for power transmission the simulation program is developed using the modeling and analysis technique. The results from this study will be used in designing the basic structure of automatic transmission using planetary gear system.

  • PDF

Measurement of Peak-to-Average Power Ratio for HRIT

  • Park Durk-Jong;Yang Hyung-Mo;Ahn Sang-Il
    • Proceedings of the KSRS Conference
    • /
    • 2004.10a
    • /
    • pp.498-500
    • /
    • 2004
  • QPSK (Quaternary Phase Shift Keying) will be adopted as the modulation of HRIT (High Rate Information Transmission) which is transmitted to COMS (Communication, Ocean and Meteorological Satellite) through HPA (High Power Amplifier) in ground segment. Due to the nonlinearity of HPA, IMD (Inter-Modulation Distortion) of multi-carrier signals and PAPR (Peak-to-Average Power Ratio) of modulated HRIT must be considered to estimate the output power of HPA. In this paper, we measured the PAPR to various the roll-off factor of RRC (Root Raised Cosine filter) which is filtering the modulated HRIT signal for reducing ISI (Inter-Symbol Interference) and bandwidth. It was found that the minimum PAPR is 2.78dB at 0.5 of roll-off factor for scrambled data. It's 2.78dB of P APR will be in output power selecting in COMS earth station.

  • PDF

A design of vertical axis wind power generating system combined with Darrieus-Savonius for adaptation of variable wind speed (다변풍속 적응형 Darrieus-Sauonius 초합 수직푹 풍력발전 시스템의 설계)

  • 서영택;오철수
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.45 no.2
    • /
    • pp.185-192
    • /
    • 1996
  • This paper presents a design of vertical axis Darrieus wind turbine combine with Savonius for wind-power generating system to be adapted for variable wind speed. The wind turbine consists of two troposkien- and four Savonius-blades. Darrieus turbine is designed with diameter 9.4[m], chord length 380[mm], tip speed ratio 5. Savonius turbine is designed with diameter 1.8[m], height 2[m], tip speed ratio 0.95. The design of turbine is laid for the main data of rated wind speed 10[m/s], turbine speed 101.4[rpm]. The generating power is estimated to maximum power 20[kW], and this is converted to commercial power line by means of three phase synchronous generator-inverter system. Generating system is designed for operation on VSVF(variable speed variable frequency) condition and constant voltage system.

  • PDF

A Study on Reverse Link Power Ratio and Channel Estimation Length Optimization of Synchronous DS-CDMA System (동기식 DS-CDMA 시스템의 역방향 채널 전력비와 채널 추정 길이의 최적화에 관한 연구)

  • 박진홍;강성진;강병권;김선형
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2000.05a
    • /
    • pp.222-225
    • /
    • 2000
  • In this paper, a synchronous CDMA system accepted for the cdma2000 standard is simulated to propose optimized reverse link power ratio and channel estimation lengths. Differently from IS-95, the pilot channel is used in the proposed system to estimate fading channel, so optimized estimation lengths are needed. Therefore, in this paper we analyze optimized estimation lengths which is needed to decide the power ratio of pilot channel and fundamental channel. From fixed estimation lengths, we calculate FER with various power ratio values.

  • PDF

Hydrodynamically Optimal Blade Design for 500kW Class Horizontal Axis Tidal Current Turbine (500kW급 수평축 조류발전기의 수력 최적 설계)

  • Ryu, Ki-Wahn
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.5
    • /
    • pp.73-80
    • /
    • 2009
  • A tidal current turbine is designed and analyzed numerically by using blade element momentum theory. The rated power has a limitation because the diameter of the tidal current turbine cannot exceed the depth of sea water. This study investigates a horizontal axis tidal-current turbine with a rated power of 500 kW. NACA-6 series laminar foil shape is used for basic airfoil along the blade span. The distributions of chord length and twist angle along the blade span are obtained from the hydrodynamic optimization procedure. Prandtl's tip loss correction and angle of attack correction considering the three-dimensional effect are applied for this study. The power coefficient curve shows maximum peak at the rated tip speed ratio of 6.0, and the maximum torque coefficient is developed at the tip speed ratio of 4. The drag coefficient reaches about 0.85 at the design tip speed ratio.

Frequency Bin Alignment Using Covariance of Power Ratio of Separated Signals in Multi-channel FD-ICA (다채널 주파수영역 독립성분분석에서 분리된 신호 전력비의 공분산을 이용한 주파수 빈 정렬)

  • Quan, Xingri;Bae, Keunsung
    • Phonetics and Speech Sciences
    • /
    • v.6 no.3
    • /
    • pp.149-153
    • /
    • 2014
  • In frequency domain ICA, the frequency bin permutation problem falls off the quality of separated signals. In this paper, we propose a new algorithm to solve the frequency bin permutation problem using the covariance of power ratio of separated signals in multi-channel FD-ICA. It makes use of the continuity of the spectrum of speech signals to check if frequency bin permutation occurs in the separated signal using the power ratio of adjacent frequency bins. Experimental results have shown that the proposed method could fix the frequency bin permutation problem in the multi-channel FD-ICA.

A Study of the SPR (Singing Power Ratio) on the Singing Voice in Singing Students (성악 전공 학생의 가칭 시 음성의 SPR(Singing Power Ratio)에 관한 연구)

  • Jo, Sung-Mi;Jeong, Ok-Ran;Lee, Sang-Ouk
    • Speech Sciences
    • /
    • v.11 no.4
    • /
    • pp.121-127
    • /
    • 2004
  • This study attempted to provide a spectrum analysis for quantitative evaluation of singing voice quality of singing students rather than the presence or absence of the singer's formant. The regression analysis was used to analyse the relationship between ringing quality, SPR, and SPP of singing voice of college student subjects majoring in music. This study measured singing. power ratio (SPR) in 41 singing students. Digital audio recordings were made in sung vowels for acoustic analyses. Each sample was judged by 1 experienced singing teacher and 4 voice pathologists on one semantic bipolar 7-point scales (ringing-dull). The results showed that the SPR and SPP had significant correlations with ringing quality. The SPR had a significant relationship with ringing quality on singing voice in singing students. The SPR can be an important quantitative measurement for evaluating singing voice quality.

  • PDF

Performance Characteristics of Hydro-mechanical Transmission and Design Parameters for Type Selection (정유압-기계식 변속기의 성능 특성과 형식 선정을 위한 설계 변수)

  • Sim, Dong-Guk;Kim, Kyeong-Uk;Han, Jung-Soo
    • Journal of Biosystems Engineering
    • /
    • v.36 no.6
    • /
    • pp.422-433
    • /
    • 2011
  • Market demand for hydro-mechanical transmission (HMT) for agricultural tractors has increased recently. To select a type of HMT satisfying design conditions, performance characteristics of 12 HMT types must be understood. This study was conducted to provide tractor engineers with a guideline to select the most appropriate HMT type for their design requirements. Characteristics on speed reduction ratio, power transmission efficiency, power regeneration, lock-up angular velocity, output torque ratio and torque ratio of planetary gear train axis of the 12 HMT types were investigated and presented as either formula or graphical forms. A guideline to select proper HMT type was also presented using 2 parameter: lock-up angular velocity (${\omega}_L$) and torque ratio of the planetary gear train axis. In addition, effect of gear ratio of the planetary gear train on the power transmission efficiency was investigated and a guideline to select the best gear ratio was also presented.