• 제목/요약/키워드: Power ratio

검색결과 6,492건 처리시간 0.031초

마이크로파 실내 배전용 저반사형 전력 분배 스위치 (Low Loss Power Dividing Switch for Indoor Microwave Power Distribution)

  • 최영규
    • 전기학회논문지
    • /
    • 제62권1호
    • /
    • pp.90-94
    • /
    • 2013
  • A low loss power dividing switch in a indoor microwave power distribution system is proposed and designed with a various power dividing ratio. Switching characteristics are analyzed by use of the S-parameter of the switch. Newly proposed switch showed a very low return loss less than -30dB at the operating frequency of 2.45GHz. Three kinds of the switch in which we take out individually 1/2, 1/3 and 1/4 of the input power were fabricated, and measured the delivered, transmitted, and return loss power ratio. Simulated results showed that the lower power ratio is, the better accurate operating performance shows. This switch can switch the input power from 4.5% to 58% with the variance of 5% output power. The experimental results are in good agreement with the simulation within the return loss of 1%.

보장구획의 장단변화에 따른 경운기의 기종별 이경작업 효력에 관한 연구 (studdyon the Field Efficiency of the Plowing Operation of the Power Tillers in accordance withthe Various Field Dimensions.)

  • 최규홍;김종관
    • Journal of Biosystems Engineering
    • /
    • 제2권1호
    • /
    • pp.49-54
    • /
    • 1977
  • In order to obtain the field efficiency of the power tiller plowing on the various size of and its length-width field tests were performed with 8ps.10ps. power tiller popularly used in the korean rural area, and Satoh 5ps. made in Japan, Land Master 5ps. made in England were tested to compare with the field efficiency of the above power tillers. The results obtained in this tests were as follows ; 1. In considering of the resting time and the refueling time and others, the field efficiency of Satoh was the highest among the power tillers as to be 80%, at the 8ps. power tiller 76.5%, at the 10ps. power tiller 79.3% and the lowest field efficiency was obtained at the Land Master as 75.7%. 2. The field efficiency of the each power tiller increased as the ratio of the length to width of the field was increased. 3. The increasing rate of field efficiency was much bigger in the below the ratio of 5 : 1 but at the upper ratio increased above, the ratio was nearly constant. 4. The field efficiency of the power tiller was higher at the smaller power tiller than the larger, except the Land Master , because of easily operating and turning of the power tiller by virtue of its lighter weight.

  • PDF

플라즈마 원자층증착 초박막전해질 수소 세라믹연료전지의 초기성능 저하 (Initial Performance Degradation of Hydrogen-Fueled Ceramic Fuel Cell with Plasma-Enhanced Atomic Layer-Deposited Ultra-Thin Electrolyte)

  • 지상훈
    • 한국수소및신에너지학회논문집
    • /
    • 제32권5호
    • /
    • pp.340-346
    • /
    • 2021
  • The initial electrochemical performance of ceramic fuel cell with thin-film electrolyte fabricated by plasma-enhanced atomic layer deposition method was evaluated in terms of peak power density ratio, open circuit voltage ratio, and activation/ohmic resistance ratios at 500℃. Hydrogen and air were used as anode fuel and cathode fuel, respectively. The peak power density ratio reduced as ~52% for 30 min, which continually decreased as time increased but degradation rate gradually decreased. The open circuit voltage ratio decreased with respect time; however, its behavior was evidently different from the reduction behavior of the peak power density. The activation resistance ratio increased as ~127% for 30 min, which was almost similar with the reduction behavior of the peak power density ratio.

A Maximum Power Point Tracking Control for Photovoltaic Array without Voltage Sensor

  • Senjyu, Tomonobu;Shirasawa, Tomiyuki;Uezato, Katsumi
    • Journal of Power Electronics
    • /
    • 제2권3호
    • /
    • pp.155-161
    • /
    • 2002
  • This paper presents a maximum power point tracking algorithm for Photovoltaic array using only instantaneous output current information. The conventional Hill climbing method of peak power tracking has a disadvantage of oscillations about the maximum power point. To overcome this problem, we have developed an algorithm that will estimate the duty ratio corresponding to maximum power operation of solar cell. The estimation of the optimal duty ratio involves, finding the duty ratio at which integral value of output current is maximum. For the estimation, we have used the well know Lagrange's interpolation method. This method can track maximum power point quickly even for changing solar isolation and avoids oscillations after reaching the maximum power point.

실내 마이크로파 배전용 완전 정합형 전력 분배 스위치의 설계 (Matching-type Power Dividing Switch for Low Reflection in Indoor Microwave Power Distribution)

  • 최영규
    • 전기학회논문지
    • /
    • 제62권6호
    • /
    • pp.792-797
    • /
    • 2013
  • In a indoor microwave power distribution system, matching-type power dividing switch is proposed and designed with a various power dividing ratio. A matching coaxial cable probe is used behind the output probe for the reflecting power absorption. Reflecting characteristics of the matching coaxial cable probe are calculated by analyzing the S-parameter of this structure. Newly proposed matching-type switch shows a very low return loss less than -30dB at the operating frequency of 2.45GHz with a dividing power ratio of 50.2%. The simulated results by use of 3-stage power divider shows a good agreement with the theoretical estimation for the various combination of the different switching ratio.

The Effect of Increasing Control-to-case Ratio on Statistical Power in a Simulated Case-control SNP Association Study

  • Kang, Moon-Su;Choi, Sun-Hee;Koh, In-Song
    • Genomics & Informatics
    • /
    • 제7권3호
    • /
    • pp.148-151
    • /
    • 2009
  • Generally, larger sample size leads to a greater statistical power to detect a significant difference. We may increase the sample size for both case and control in order to obtain greater power. However, it is often the case that increasing sample size for case is not feasible for a variety of reasons. In order to look at change in power as the ratio of control to case varies (1:1 to 4:1), we conduct association tests with simulated data generated by PLINK. The simulated data consist of 50 disease SNPs and 300 non-disease SNPs and we compute powers for disease SNPs. Genetic Power Calculator was used for computing powers with varying the ratio of control to case (1:1, 2:1, 3:1, 4:1). In this study, we show that gains in statistical power resulting from increasing the ratio of control to case are substantial for the simulated data. Similar results might be expected for real data.

한국 RE100 기업의 자가소비 태양광 발전 경제적 비율 분석 (Self-Consumption Solar PV Economic Rate Analysis for RE100 Companies in Korea)

  • 이종의;김경남
    • Current Photovoltaic Research
    • /
    • 제11권4호
    • /
    • pp.134-143
    • /
    • 2023
  • Efforts are being made to respond to global warming. Interest in and demand for the private sector-led RE100 campaign is also increasing. Self-built solar power generation, one of the implementation tools for RE100, is not expanding. However, it can be an economical means of implementation in the long run. In this study, we intend to analyze the impact on the optimal ratio of self-solar power generation using HOMER simulation. OPR defines the optimal solar power generation ratio and looks into what changes there are in the optimal solar power ratio when self-power consumption increases and external power purchase price changes. As a result, the optimal rate of self-solar power generation has a low impact even if self-power consumption increases. As the external power unit price increases, the optimal ratio increases, and at a power unit price of 100 KRW/kWh, OPR is 24%; at 200 KRW/kWh OPR is 31%; and at 300 KRW/kWh OPR is 34%. This shows that the electricity price replaced during the life cycle has a high impact on the economic feasibility of solar power generation. However, when the external power unit price reached a certain level, the increase in OPR decreased. This shows that it is difficult for domestic companies to achieve RE100 based on the economic feasibility of solar energy alone. Therefore, efforts are needed to supply renewable energy in the public sector.

A Maximum Power Point Tracking Control for Photovoltaic Array without Voltage Sensor

  • Senjyu Tomonobu;Shirasawa Tomiyuki;Uezato Katsumi
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.617-621
    • /
    • 2001
  • This paper presents a maximum power point tracking algorithm for Photovoltaic array using only instantaneous output current information. The conventional Hill climbing method of peak power tracking has a disadvantage of oscillations about the maximum power point. To overcome this problem, we have developed a algorithm, that will estimate the duty ratio corresponding to maximum power operation of solar cell. The estimation of the optimal duty ratio involves, finding the duty ratio at which integral value of output current is maximum. For the estimation, we have used the well know Lagrange's interpolation method. This method can track maximum power point quickly even for changing solar insolations and avoids oscillations after reaching the maximum power point.

  • PDF

Accurate Power Sharing in Proportion for Parallel Connected Inverters by Reconstructing Inverter Output Impedance

  • Huang, Shengli;Luo, Jianguo
    • Journal of Power Electronics
    • /
    • 제18권6호
    • /
    • pp.1751-1759
    • /
    • 2018
  • This paper presents parallel-connected inverters to achieve accurate proportional power sharing. Due to line impedance mismatch, reactive power cannot be distributed proportionally when using the conventional $P-{\omega}$ and $\mathcal{Q}-E$ droop. In order to realize reactive proportional power sharing, the ratio of the droop coefficients should be inversely proportional to their power-sharing ratios. Meanwhile, the ratio of the line impedance should be inversely proportional to the desired power-sharing ratio, which is very difficult to be met in practice. In order to deal with this issue, a practical control strategy is presented. By measuring the PCC voltage and using the virtual impedance, the output impedance of individual inverters is reconstructed to counteract the line impedance effect. In order to guarantee system stability, a low pass filter is designed to suppress the bandwidth of the line compensation. Finally, the simulation and experimental results are given to verify the effectiveness of the proposed control strategy.

저온도차 모형 스털링 엔진의 최대출력 설계조건 (DESIGN OF A LOW TEMPERATURE DIFFERENCE STIRLING ENGINE)

  • 정평석;원민영;김수연
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.420-423
    • /
    • 2003
  • A low temperature difference model Stirling engine is a small Stirling engine running with several degree of temperature difference without power output. In this study, the design parameters to give maximum power are discussed. As results, the phase angle is about 100 degree, and compression ratio is 1.5% of the ratio of heat source temperatures at maximum power condition.

  • PDF