• 제목/요약/키워드: Power peak-cut

검색결과 46건 처리시간 0.032초

전력선통신을 이용한 소규모 주택용 맞춤형 전력피크 제어시스템 개발 (Development of Adaptive Home Power Peak-Cut Control System Using Power Line Communication)

  • 김상동;박지호;김동완
    • 전기학회논문지
    • /
    • 제65권1호
    • /
    • pp.219-226
    • /
    • 2016
  • In this paper, adaptive home power peak-cut control system is developed using PLC. The developed scheme provides monitoring of power usage, power peak-cut control and additional function. In test bed, zone is presented by bedroom, living room, kitchen and bathroom. And individual load is presented by lighting, heater and fan in zone. In developed scheme, zone control is implemented by single PLC modem. And individual load control is implemented by key-map table. In addition, power peak-cut control system S/W, which can perform setting of power peak, power peak-cut control and monitoring of power usage.

Utility Interactive PV Systems with Power Shaping Function for Increasing Peak Power Cut Effect

  • Choe, Gyu-Ha;Kim, Hong-Sung;Heo, Hye-Seong;Jeong, Byong-Hwan;Choi, Young-Ho;Kim, Jae-Chul
    • Journal of Power Electronics
    • /
    • 제8권4호
    • /
    • pp.371-380
    • /
    • 2008
  • This paper describes the Utility Interactive PV (UIPV) system which can improve the peak-cut effect by adding an energy storage device of batteries to the power converter. The proposed system has three possible operation modes depending on relative condition of PV output, which can have the power shaping function covering the peak power for 3 hours. A new power circuit and an application algorithm have been applied to the UIPV system which is based on working PV system during a 3-hour peak time. The energy relationship by the proposed system is analyzed theoretically and experimentally. The proposed system is evaluated at the viewpoint of cost and total spacing, which enables the proposed UIPV system to have the reduction of the peak power demand and hence to improve the power capacity of peak cut.

에너지 저장장치를 갖는 피크컷 세이버 시스템의 출력특성 연구 (Output Characteristics of Peak-Cut Saver System with Energy Storage Device)

  • 서현욱;한동화;이영진;전태원;최규하
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2011년도 추계학술대회
    • /
    • pp.231-232
    • /
    • 2011
  • It is very important thing to efficiently utilize the solar power. The conventional solar power system has no energy storage device. So the conventional system cannot cut the peak load. In this paper, the solar power system with the energy storage device and the operation algorithm of peak cut function was proposed to cut the peak load. The algorithm principle is proposed based on the insolation curve and load curve. The simulation and experiment was performed to demonstrate the validity of the peak cut algorithm.

  • PDF

수용가 대응용 태양광 ESS 피크컷(Peak-cut) 시뮬레이션 모델 (Solar ESS Peak-cut Simulation Model for Customer)

  • 박성현;이기현;정명석;채우리;이주연
    • 디지털융복합연구
    • /
    • 제17권7호
    • /
    • pp.131-138
    • /
    • 2019
  • 전 세계 전력 생산 에너지의 비율은 석탄이 40%, 천연가스 20%, 수력 16%, 원자력 15%, 석유 6%로 모두가 환경오염을 유발하는 에너지다. 또한 화석연료는 지구상에 자원의 편중이 심하기 때문에 가격과 공급면에서 심각한 문제를 야기한다. 이러한 문제로 화석 연료를 대체하게 될 차세대 친환경 에너지로써 태양광 에너지가 각광 받고 있다. 이에 본 연구에서는 국내 공단에 Test-Bed를 선정하여 수용가의 대응용 태양광 ESS 시스템 적용함에 있어 Peak-cut 운영을 위한 Charge Operation Plan과 Discharge Operation Plan 운영방안을 최대수요전력 감소 시뮬레이션을 통해 검증하고자 한다. 이를 위해 전력사용량이 가장 많은 11월부터 2월의 전력사용량을 선정하여 Charge/Discharge Logic을 적용했다. 본 논문에서 제시한 충전/방전 로직에 따른 시뮬레이션 결과, ESS Peak-cut 서비스 이후의 최대수요전력이 감소하였으며 Peak-target 전력의 50%로 감소함에 따라 계약전력 또한 감소함을 알 수 있다. 이를 통해 계약전력 감소는 해당 수용가의 기본 전력 값을 감소시켜, 경제적 우월성을 기대할 수 있을 뿐만 아니라 전기품질 향상 및 전력공급시스템의 안정화에도 기여할 수 있을 것으로 판단된다.

가스냉방 전력대체효과 분석 (Analysis of Electric Power Peak-Cut Effect by Gas Cooling)

  • 정시영;김대환;박기웅
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.208-211
    • /
    • 2009
  • To reduce the peak demand the promotion of gas cooling(absorption chillers and GHPs) is required. In this study the effect of electric power peak-cut has been analyzed using two methods. One is based on monthly LNG consumption data and the other is using the gas cooling capacity installed. Both methods agreed well with each other within the uncertainty of 20%. It was found that the gas cooling had the peak cut effect of 1,500-2,000 MW for recent 5 years (2003 - 2007). The ratio of gas cooling to the whole cooling demand was 12-15%, which is needed to be increased.

  • PDF

첨두부하 삭감효과를 갖는 UIPV시스템의 개선된 운용방법 (Improved Operating Method of Utility Interactive PV System for Peak Power Cut Effect)

  • 김영식;바이스갈랑;허혜성;최규하
    • 전력전자학회논문지
    • /
    • 제14권5호
    • /
    • pp.415-422
    • /
    • 2009
  • 본 논문은 기존의 시스템에 비해 시스템의 전력회로 구조의 큰 변경 없이 밧데리와 같은 전력저장 장치 디바이스의 추가와 개선된 운용방법을 적용한 첨두부하 삭감효과를 갖는 계통연계형 태양광발전시스템(UIPV)을 제안하였다. 개선된 운용방법과 에너지 저장장치의 추가로 기존 시스템에 비해 PV-array 용량을 작게 설치하여도 첨두부하 삭감효과를 크게 할 수 있으며, 가격 및 설치공간 등의 면에서 평가하여 기존시스템보다 더 나아짐을 확인하였다.

피크부하용 혼소엔진발전의 경제성 분석 (An Economic Analysis on Dual-fuel Engine Generation for Peak Load)

  • 이옥배;안재경
    • 전기학회논문지
    • /
    • 제61권9호
    • /
    • pp.1260-1268
    • /
    • 2012
  • Recently, lack of power reserve margin was observed quite often. In this paper, we studied the method to secure power source for a short time, to cut the utility power peak load, and to reduce the users electricity bills. Emergency diesel generator of an office building is to be converted into a dual-fuel engine generator which is responsible for a portion of the peak load. Compared to the conventional diesel fuel generator, the proposed dual-fuel engine is able to reduce the generation power cost by dual-fuel combustion, and it also mitigates the building's utility power peak load by charging the building's peak load. If the dead resources (a group of emergency dual-fuel engine generators), as a Virtual Power Plant, are operating in peak time, we can significantly reduce future large power development costs. We investigated the current general purpose electricity bills as well as the records of the building electric power usage, and calculated diesel engine generator renovation costs, generation fuel costs, driving conditions, and savings in electricity bills. The proposed dual-fuel engine generation method reduces 18.1% of utility power peak load, and turned out to be highly attractive investment alternative which shows more than 27% of IRR, 76 million won of NPV, and 20~53 months of payback periods. The results of this study are expected to be useful to developing the policy & strategy of the energy department.

Thermal-Aware Floorplanning with Min-cut Die Partition for 3D ICs

  • Jang, Cheoljon;Chong, Jong-Wha
    • ETRI Journal
    • /
    • 제36권4호
    • /
    • pp.635-642
    • /
    • 2014
  • Three-dimensional integrated circuits (3D ICs) implement heterogeneous systems in the same platform by stacking several planar chips vertically with through-silicon via (TSV) technology. 3D ICs have some advantages, including shorter interconnect lengths, higher integration density, and improved performance. Thermal-aware design would enhance the reliability and performance of the interconnects and devices. In this paper, we propose thermal-aware floorplanning with min-cut die partitioning for 3D ICs. The proposed min-cut die partition methodology minimizes the number of connections between partitions based on the min-cut theorem and minimizes the number of TSVs by considering a complementary set from the set of connections between two partitions when assigning the partitions to dies. Also, thermal-aware floorplanning methodology ensures a more even power distribution in the dies and reduces the peak temperature of the chip. The simulation results show that the proposed methodologies reduced the number of TSVs and the peak temperature effectively while also reducing the run-time.

교류 고속철도계통에서 BESS의 도입을 위한 전력소비 및 충·방전효과 분석에 관한 연구 (Study on Analysis for Power Consumption and Charge/Discharge Effect with BESS in AC High-Speed Electric Railway System)

  • 전용주;강병욱;채희석;김재철
    • 조명전기설비학회논문지
    • /
    • 제28권9호
    • /
    • pp.20-27
    • /
    • 2014
  • The power consumption pattern of high-speed railway has rarely during night time. But, during service time, the power is consumed irregularly related to train operation. Especially certain unusual about 1-2 days of service time interval to indicate the power consumption is rapidly growing phenomenon, which causes the capacity of the power contract is the annual electricity bill to rise rapidly as the cause. Normally, amount of peak power consumption bill rate at railway substation is over 20% of total electrical bill. Therefore, high-speed railway substation is expected to be considerably larger savings by reducing the peak power of the default charge(demand power).

금속 부품 열처리업체의 최대전력절감장치 동작 특성 및 효과 분석 (Performence Characteristics and Analysis Effect of Maximum Power Saving Device in Metal Parts Heat Treatment Company)

  • 장홍순;한영섭;황익환;서상현
    • 조명전기설비학회논문지
    • /
    • 제28권6호
    • /
    • pp.40-44
    • /
    • 2014
  • In this paper, maximum power is the lowering device using the facility's energy use and peak load electricity through analyzing attitude should like to make it reduce its power base rate. Simulator to manage the demand for power, a maximum electric power base power from electronic watt-hour meters by a device's signal, predictive power, the current power by computing the goal of power for less than Maximum peak power and peak shift, so that you can manage, and peak York, which role you want a cut Metal heat treatment result which analyzes the data, demand for electricity company over the years of analyzing the characteristics of each load, and effects and Reducing power consumption device every month identified seven Sequence control to the load system and successful power control is about showing that the defined goals.