• Title/Summary/Keyword: Power peak-cut

Search Result 46, Processing Time 0.027 seconds

Development of Adaptive Home Power Peak-Cut Control System Using Power Line Communication (전력선통신을 이용한 소규모 주택용 맞춤형 전력피크 제어시스템 개발)

  • Kim, Sang-Dong;Park, Ji-Ho;Kim, Dong-Wan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.1
    • /
    • pp.219-226
    • /
    • 2016
  • In this paper, adaptive home power peak-cut control system is developed using PLC. The developed scheme provides monitoring of power usage, power peak-cut control and additional function. In test bed, zone is presented by bedroom, living room, kitchen and bathroom. And individual load is presented by lighting, heater and fan in zone. In developed scheme, zone control is implemented by single PLC modem. And individual load control is implemented by key-map table. In addition, power peak-cut control system S/W, which can perform setting of power peak, power peak-cut control and monitoring of power usage.

Utility Interactive PV Systems with Power Shaping Function for Increasing Peak Power Cut Effect

  • Choe, Gyu-Ha;Kim, Hong-Sung;Heo, Hye-Seong;Jeong, Byong-Hwan;Choi, Young-Ho;Kim, Jae-Chul
    • Journal of Power Electronics
    • /
    • v.8 no.4
    • /
    • pp.371-380
    • /
    • 2008
  • This paper describes the Utility Interactive PV (UIPV) system which can improve the peak-cut effect by adding an energy storage device of batteries to the power converter. The proposed system has three possible operation modes depending on relative condition of PV output, which can have the power shaping function covering the peak power for 3 hours. A new power circuit and an application algorithm have been applied to the UIPV system which is based on working PV system during a 3-hour peak time. The energy relationship by the proposed system is analyzed theoretically and experimentally. The proposed system is evaluated at the viewpoint of cost and total spacing, which enables the proposed UIPV system to have the reduction of the peak power demand and hence to improve the power capacity of peak cut.

Output Characteristics of Peak-Cut Saver System with Energy Storage Device (에너지 저장장치를 갖는 피크컷 세이버 시스템의 출력특성 연구)

  • Seo, Hyou-Uk;Han, D.H;Lee, Y.J;Chun, T.W;Choe, Gyu-Ha
    • Proceedings of the KIPE Conference
    • /
    • 2011.11a
    • /
    • pp.231-232
    • /
    • 2011
  • It is very important thing to efficiently utilize the solar power. The conventional solar power system has no energy storage device. So the conventional system cannot cut the peak load. In this paper, the solar power system with the energy storage device and the operation algorithm of peak cut function was proposed to cut the peak load. The algorithm principle is proposed based on the insolation curve and load curve. The simulation and experiment was performed to demonstrate the validity of the peak cut algorithm.

  • PDF

Solar ESS Peak-cut Simulation Model for Customer (수용가 대응용 태양광 ESS 피크컷(Peak-cut) 시뮬레이션 모델)

  • Park, Seong-Hyeon;Lee, Gi-Hyun;Chung, Myoung-Sug;Chae, U-ri;Lee, Joo-Yeuon
    • Journal of Digital Convergence
    • /
    • v.17 no.7
    • /
    • pp.131-138
    • /
    • 2019
  • The world's electricity production ratio is 40% for coal, 20% for natural gas, 16% for hydroelectric power, 15% for nuclear power and 6% for petroleum. Fossil fuels also cause serious problems in terms of price and supply because of the high concentration of resources on the earth. Solar energy is attracting attention as a next-generation eco-friendly energy that will replace fossil fuels with these problems. In this study, we test the charge-operation plan and the discharge operation plan for peak-cut operation by applying the maximum power demand reduction simulation. To do this, we selected the electricity usage from November to February, which has the largest amount of power usage, and applied charge / discharge logic. Simulation results show that the contract power decreases as the peak demand power after the ESS Peak-cut service is reduced to 50% of the peak-target power. As a result, the contract power reduction can reduce the basic power value of the customer and not only the economic superiority can be expected, but also contribute to the improvement of the electric quality and stabilization of the power supply system.

Analysis of Electric Power Peak-Cut Effect by Gas Cooling (가스냉방 전력대체효과 분석)

  • Jeong, Si-Young;Kim, Dae-Hwan;Park, Ki-Woong
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.208-211
    • /
    • 2009
  • To reduce the peak demand the promotion of gas cooling(absorption chillers and GHPs) is required. In this study the effect of electric power peak-cut has been analyzed using two methods. One is based on monthly LNG consumption data and the other is using the gas cooling capacity installed. Both methods agreed well with each other within the uncertainty of 20%. It was found that the gas cooling had the peak cut effect of 1,500-2,000 MW for recent 5 years (2003 - 2007). The ratio of gas cooling to the whole cooling demand was 12-15%, which is needed to be increased.

  • PDF

Improved Operating Method of Utility Interactive PV System for Peak Power Cut Effect (첨두부하 삭감효과를 갖는 UIPV시스템의 개선된 운용방법)

  • Kim, Young-Sik;Bayasgalan, Dugarjav;Heo, Hye-Seong;Choe, Gyu-Ha
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.14 no.5
    • /
    • pp.415-422
    • /
    • 2009
  • This paper describes the UIPV(Utility Interactived Photovoltaic) system which can improve the peak-cut effect by adding energy storage device of batteries to the power converter. The proposed system has three possible operation modes depending on relative condition of PV output, which can have the power shaping function covering the peak power for 3 hours. A new power circuit and application algorithm has been applied to UIPV system which is based on working PV system during 3-hour peak time. The energy relationship by the proposed system is analyzed theoretically and experimentally. Also the proposed system is evaluated at the viewpoint of cost and total spacing, which enables the proposed UIPV system to have the reduction of the peak power demand and hence to improve.

An Economic Analysis on Dual-fuel Engine Generation for Peak Load (피크부하용 혼소엔진발전의 경제성 분석)

  • Lee, Ok-Bae;Ahn, Jae-Kyoung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.9
    • /
    • pp.1260-1268
    • /
    • 2012
  • Recently, lack of power reserve margin was observed quite often. In this paper, we studied the method to secure power source for a short time, to cut the utility power peak load, and to reduce the users electricity bills. Emergency diesel generator of an office building is to be converted into a dual-fuel engine generator which is responsible for a portion of the peak load. Compared to the conventional diesel fuel generator, the proposed dual-fuel engine is able to reduce the generation power cost by dual-fuel combustion, and it also mitigates the building's utility power peak load by charging the building's peak load. If the dead resources (a group of emergency dual-fuel engine generators), as a Virtual Power Plant, are operating in peak time, we can significantly reduce future large power development costs. We investigated the current general purpose electricity bills as well as the records of the building electric power usage, and calculated diesel engine generator renovation costs, generation fuel costs, driving conditions, and savings in electricity bills. The proposed dual-fuel engine generation method reduces 18.1% of utility power peak load, and turned out to be highly attractive investment alternative which shows more than 27% of IRR, 76 million won of NPV, and 20~53 months of payback periods. The results of this study are expected to be useful to developing the policy & strategy of the energy department.

Thermal-Aware Floorplanning with Min-cut Die Partition for 3D ICs

  • Jang, Cheoljon;Chong, Jong-Wha
    • ETRI Journal
    • /
    • v.36 no.4
    • /
    • pp.635-642
    • /
    • 2014
  • Three-dimensional integrated circuits (3D ICs) implement heterogeneous systems in the same platform by stacking several planar chips vertically with through-silicon via (TSV) technology. 3D ICs have some advantages, including shorter interconnect lengths, higher integration density, and improved performance. Thermal-aware design would enhance the reliability and performance of the interconnects and devices. In this paper, we propose thermal-aware floorplanning with min-cut die partitioning for 3D ICs. The proposed min-cut die partition methodology minimizes the number of connections between partitions based on the min-cut theorem and minimizes the number of TSVs by considering a complementary set from the set of connections between two partitions when assigning the partitions to dies. Also, thermal-aware floorplanning methodology ensures a more even power distribution in the dies and reduces the peak temperature of the chip. The simulation results show that the proposed methodologies reduced the number of TSVs and the peak temperature effectively while also reducing the run-time.

Study on Analysis for Power Consumption and Charge/Discharge Effect with BESS in AC High-Speed Electric Railway System (교류 고속철도계통에서 BESS의 도입을 위한 전력소비 및 충·방전효과 분석에 관한 연구)

  • Jeon, Yong-Joo;Kang, Byoung-Wook;Chai, Hui-Seok;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.9
    • /
    • pp.20-27
    • /
    • 2014
  • The power consumption pattern of high-speed railway has rarely during night time. But, during service time, the power is consumed irregularly related to train operation. Especially certain unusual about 1-2 days of service time interval to indicate the power consumption is rapidly growing phenomenon, which causes the capacity of the power contract is the annual electricity bill to rise rapidly as the cause. Normally, amount of peak power consumption bill rate at railway substation is over 20% of total electrical bill. Therefore, high-speed railway substation is expected to be considerably larger savings by reducing the peak power of the default charge(demand power).

Performence Characteristics and Analysis Effect of Maximum Power Saving Device in Metal Parts Heat Treatment Company (금속 부품 열처리업체의 최대전력절감장치 동작 특성 및 효과 분석)

  • Chang, Hong-Soon;Han, Young-Sub;Hwang, Ik-Hwan;Seo, Sang-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.6
    • /
    • pp.40-44
    • /
    • 2014
  • In this paper, maximum power is the lowering device using the facility's energy use and peak load electricity through analyzing attitude should like to make it reduce its power base rate. Simulator to manage the demand for power, a maximum electric power base power from electronic watt-hour meters by a device's signal, predictive power, the current power by computing the goal of power for less than Maximum peak power and peak shift, so that you can manage, and peak York, which role you want a cut Metal heat treatment result which analyzes the data, demand for electricity company over the years of analyzing the characteristics of each load, and effects and Reducing power consumption device every month identified seven Sequence control to the load system and successful power control is about showing that the defined goals.