• Title/Summary/Keyword: Power oscillation

Search Result 541, Processing Time 0.034 seconds

The Fine Power Spectra of the Southern Oscillation Index and Its Components and their Implication

  • Lim, G.-H.;Suh, Y.-C.
    • Atmosphere
    • /
    • v.25 no.3
    • /
    • pp.559-568
    • /
    • 2015
  • As is evident from its definition, Southern Oscillation Index variability conformed to a combination of the variations of Darwin and Tahiti pressure. Over the El-$Ni{\tilde{n}}o$ Southern Oscillation spectra, the Darwin pressure shared variations associated with the SSN tendency while the Tahiti had a connection with the stratospheric quasi-biennial oscillation modulating annual cycle. The power peak near the 3.5-year period comprised the third harmonic of the sun and the second of the modulated annual cycle. The derived harmonics came from both sources, so the initiation of El-$Ni{\tilde{n}}o$ could be predicted more successfully when including the effects of the sun and QBO.

Experimental Study and Numerical Simulation of Cavity Oscillation in a Conical Diffuser

  • Chen, Chang-Kun;Nicolet, Christophe;Yonezawa, Koichi;Farhat, Mohamed;Avellan, Francois;Miyazawa, Kazuyoshi;Tsujimoto, Yoshinobu
    • International Journal of Fluid Machinery and Systems
    • /
    • v.3 no.1
    • /
    • pp.91-101
    • /
    • 2010
  • Based on the one-dimensional stability analysis, the self-excited oscillation in hydraulic power generating systems was studied by a simple experiment and numerical simulation. It was shown that a cavity in a conical diffuser can cause surge. With the diffuser, a high amplitude and low frequency oscillation occurs at low cavitation number. This oscillation was not observed with the straight pipe. It was confirmed that the diffuser effect of the draft tube can be the cause of the full load surge in hydraulic power system. Numerical results were also analyzed to check the validity of the one-dimensional stability analysis.

Application and Control of UPFC for Improving Power System Oscillation Damping (전력시스템 동요억제를 위한 UPFC 적용 및 제어)

  • Kim, Y.S.;Kim, T.J.;Lee, B.H.;Han, H.G.;Son, K.M.;Park, J.K.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07c
    • /
    • pp.1124-1126
    • /
    • 1997
  • The Unified Power Flow Controller(UPFC) with a series inverter and a shunt inverter ia able to control all three line Parameters(voltage, impedance and phase angle) and so UPFC technology has the potential to enhance the implementation and broad application of the FACTS concept with improved Performance. In this Paper, the UPFC is applied in order to improve the power flow oscillation damping. The modal performance measure is minimized in order to determine the optimal parameters of UPFC controller for damping Power flow oscillations. The dynamics of the injected voltage of UPFC is represented as a first order delay element. The UPFC controller used here is of the PIO type and the input signal to the controller is the active power flow through the UPFC. The effect of UPFC application to the Power system are analyzed from the stand point of power system oscillation damping.

  • PDF

SVC & TCSC Effects Power System in Multi-Machine (다기계통에서의 SVC와 TCSC특성 해석)

  • Sul, Yong-Tae
    • Proceedings of the KIEE Conference
    • /
    • 1996.07b
    • /
    • pp.658-660
    • /
    • 1996
  • This paper prescribe the effects of SVC & TCSC in multi-machine power system. EMTP models of two FACTS controllers are proposed to analysis the basic characteristics of SVC & TCSC and the control signal of TCR is determined by rms value which was measured in system. The oscillation model of generator is proposed to analysis the damping effect and the most effective location of TCSC in multi-machine power system is identified by the residues associated with the natural oscillation modes. The 3 generator-9 bus model system is used to demonstrate the applicability of the proposed model.

  • PDF

Effect Analysis of the Low Frequency Oscillation Mode of Inter-area System According to Load Characteristics (부하특성이 지역간 계통의 저주파 진동 모드 해석에 미치는 영향 분석)

  • Kim, Hak-Man
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.10
    • /
    • pp.1703-1707
    • /
    • 2008
  • Low frequency oscillation of inter-area system is important problem in power system areas because the operation conditions of power system depend on it. Generally, the analysis of the problem is used by small signal stability. Especially, the analysis results are affected by decision of load models. In this paper, the effect of the analysis results was studied according to load component characteristics. ZIP model, popular in large-scaled power system analysis, was used as the load model. Many cases were studied according to the combination of ZIP model in inter-area system.

Analysis of Oscillation Modes Occurred by Thyristor Switching Operations of the TCSC in OMIB System (TCSC를 포함한 일기무한모선계통에서 싸이리스터의 스위칭에 의한 진동모드 해석)

  • Dong, Moo-Hwan;Lee, Yun-Ho;Kim, Deok-Young
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.12-13
    • /
    • 2006
  • In this paper, RCF(Resistive Companion Form) analysis method which is used to analyze small signal stability problems of non-continuous systems including switching device. The RCF analysis method are applied to the power systems with the thyristor controled FACTS equipments such as TCSC. As a result of simulation, the RCF method is very powerful to calculate the oscillation modes exactly after the switching operations, and useful to analyze the small signal stability of power systems with switching devices such as FACTS equipments. As an applicable example of the RCF method in power system, the one machine infinite bus system including TCSC at generator terminal bus is investigated and the results proved that variations of oscillation modes after periodic switching operations of TCSC can be calculated exactly.

  • PDF

Interference Cancellation System to Prevent the Oscillation of the Wireless Communication System using the Same Frequency (동일 주파수 무선통신 시스템의 발진방지를 위한 간섭잡음제거기)

  • 김선진;김남영
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.3
    • /
    • pp.253-262
    • /
    • 2003
  • In this paper, the interference cancellation system, which is used to cancel the feedback signal in the wireless communication system with the same frequency, is studied. The time varying feedback signal generated from transmitter antenna to receiver antenna reduces the performance of the receiver system. the interference cancellation system using adaptive feedback method(AF-ICS) is suggested to prevent the oscillation of the receiver system and maintain the maximum output power of the power amplifier by the reduction of time-varying feedback signal and also this paper conforms that the oscillation disappears from the output signal by cancellation of the feedback signal and the total output power is satisfied the system specification.

Suppression method for current oscillation of V/F controlled high speed induction motor (V/F 제어 고속 유도전동기의 전류 진동 억제 방법)

  • Lee, Jin-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.150-151
    • /
    • 2017
  • This paper deals with the suppression of subharmonic current oscillation of V/F controlled high speed induction motor drive in turbo blower applications. High speed induction motor has a relatively low stator impedance for high speed operation and therefore the dc link voltage ripple may result in subharmonic current oscillation at the steady state in high speed operation. This paper shows that the subharmonic oscillation is caused by the dc link voltage ripple and also proposes the suppression method, which generates the compensation voltage through the proportional current controller to reduce the subharmonic current oscillation. The simulation and experimental results show that the proposed suppression method reduces the subharmonic current oscillation to the acceptable low level in turbo blower applications.

  • PDF

A Study on the Thermoacoustic Oscillation of an Air Column (기주의 열음향진동에 관한 연구)

  • 권영필;이병호
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.11 no.2
    • /
    • pp.253-261
    • /
    • 1987
  • Thermoacoustic oscillation of an air column induced by heated wires is investigated analytically and experimentally. Acoustic power generation from a single heater wire is estimated based on the result of heat transfer analysis and expressed in terms of the efficiency factor indicating the conversion efficiency from heat to acoustic energy. It is shown that the efficiency factor becomes maximum when the wire radius is the order of the coustic boundary layer thickness and the flow velocity is close to the thermal diffusion velocity. Onset condition of the column oscillation is obtained by equating the acoustic power generation at the heater to the power loss due to thermoviscous dissipation at the tube wall and the convection and radiationloss at the open ends of the tube. In estimating the acoustic power generation, the heater is treated as a stretched single wire by correcting the flow velocity to take into account the interactions between adjacent heater wires. Experiment is performed by using a spiral heater of 1mm diameter in an air column of 37mm diameter. The heat input to drive the oscillation is measured and compared with the theoretical prediction. A good agreement is found between the theory and experiment, which is regarded as a substantial verification of the present analysis.

The Study on Pressure Oscillation and Heat Transfer Characteristics of Oscillating Capillary Tube Heat Pipe

  • Kim, Jong-Soo;Bui, Ngoc-Hung;Jung, Hyun-Seok;Lee, Wook-Hyun
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.10
    • /
    • pp.1533-1542
    • /
    • 2003
  • In the present study, the characteristics of pressure oscillation and heat transfer performance in an oscillating capillary tube heat pipe were experimentally investigated with respect to the heat flux, the charging ratio of working fluid, and the inclination angle to the horizontal orientation. The experimental results showed that the frequency of pressure oscillation was between 0.1 Hz and 1.5 Hz at the charging ratio of 40 vol.%. The saturation pressure of working fluid in the oscillating capillary tube heat pipe increased as the heat flux was increased. Also, as the charging ratio of working fluid was increased, the amplitude of pressure oscillation increased. When the pressure waves were symmetric sinusoidal waves at the charging ratios of 40 vol.% and 60 vol.%, the heat transfer performance was improved. At the charging ratios of 20 vol.% and 80 vol.%, the waveforms of pressure oscillation were more complicated, and the heat transfer performance reduced. At the charging ratio of 40. vol.%, the heat transfer performance of the OCHP was at the best when the inclination angle was 90$^{\circ}$ the pressure wave was a sinusoidal waveform, the pressure difference was at the least, the oscillation amplitude was at the least, and the frequency of pressure oscillation was the highest.