• 제목/요약/키워드: Power measurements

검색결과 1,590건 처리시간 0.028초

자동차용 양토출 단흡입 워터펌프의 성능 예측에 관한 연구 (A Study on the Performance Prediction of Automotive Water Pump with Double Discharge Single Suction)

  • 허형석;박경석;이기수;원종필
    • 한국자동차공학회논문집
    • /
    • 제12권3호
    • /
    • pp.27-36
    • /
    • 2004
  • A Numerical analysis has been used to predict the performance in the automotive water pump with double discharge single suction. The influence of parameters such as coolant flow rate, rotational speed, ratio of blade height and clearance has been investigated. Also, the prediction of hydraulic performances such as static pressure rise, shaft power, hydraulic power and pump efficiency is carried out on the water pump including an impeller and a volute casing. A full size water pump test bench has been developed to validate the CFD flow model. Discharge flow rate, suction pressure, discharge pressure, rotational speed and torque measurements are provided. Coolant temperature is 8$0^{\circ}C$, water tank pressure is 1 kgf/$\textrm{cm}^2$ and flow rates vary.

A PORTABLE TORQUE AND POWER MEASUREMENT SYSTEM FOR SMALL FARM EQUIPMENT BASED ON AN INSTRUMENTED PULLEY

  • Pasikatan, M.C.;Quick, G.R.
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 1993년도 Proceedings of International Conference for Agricultural Machinery and Process Engineering
    • /
    • pp.298-306
    • /
    • 1993
  • A portable torque and power measurement system for small farm equipment based on instrumented pulley was developed. The prototype pulley was machined from mild steel, with spokes serving as strain beams. Strain gages mounted to the spokes sense the bending strain due to the torque and convert this into millivolt output. Calibration results showed the torque-millivolt relationship was linear, while hysterisis and error were less than 1% fs. For power measurements, an additional tachmeter with dcvoltage output is necessary. With the tachometer , error in power measurement was +-1.03W or 0.2% fs. Field tests showed that for ease of installation, no machine alteration needed and safety, this system had advantage over other methods for small farm equipment.

  • PDF

CHARACTERISTICS OF RESIDUAL CARBON DERIVED FROM THE COMBUSTION OF VACUUM RESIDUE IN A TEST FURNACE

  • Park, Ho-Young;Seo, Sang-Il
    • Environmental Engineering Research
    • /
    • 제12권3호
    • /
    • pp.109-117
    • /
    • 2007
  • The characteristics of carbonaceous particles collected from the combustion of Vacuum Residue (VR) in a test furnace have been investigated. The physical and chemical characterization includes particle size, scanning electron microscopy of the surface structure, measurement of porosity, surface area and density, EDX/XRD analyses and measurement of chemical composition. The studies show that the carbonaceous VR particles are very porous and spheroidal, and have many blow-holes on the surface. The particles become smaller and more sponge-like as the reaction proceeds. The present porosity of VR particles is similar to that of cenospheres from the combustion of heavy oil, and the majority of pores are distributed in macro-pores above $0.03\;{\mu}m$ in diameter. Measurements of pore distribution and surface area showed that the macro-pores contributed most to total pore volume, whereas the micro-pores contributed to total surface area.

DUMMY모선을 고려한 상태추정 측정점선정 알고리즘에 관한 연구 (A Study on Measurement Selection Algorithm for Power System State Estimation Under the Consideration of Dummy Buses)

  • 문영현;이태식
    • 대한전기학회논문지
    • /
    • 제41권2호
    • /
    • pp.107-117
    • /
    • 1992
  • This paper presents an improved algorithm of optimal measurement design with a reliability evaluation method for a large power system. The proposed algorithm is developed to consider the dummy bus and to achieve highest accuracy of the state estimator as well with the limited investment cost. The dummy bus in the power system is impossible to install measurement meter, while real and reactive power measurements is considered in the proposed algorithm. On the other hand, P/C model is developed by taking advantage of the matrix sparsity. The improved program is successfully tested for KEPCO system with PSS/E lineflow calculated data package.

  • PDF

A Study on Configuration of Extremely Low Phase Noise Oscillator Circuit

  • Sakuta, Yukinori;Arai, Yuji;Sekine, Yoshifumi
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 ITC-CSCC -2
    • /
    • pp.1196-1199
    • /
    • 2002
  • The low phase noise frequency source to be used for measurements and so on realizes by oscillator having highly output signal power against output noise power. SAW devices can be used by high power than BAW devices. So we examine on configuration of SAW oscillator circuits with the power gain. In this paper we shall discuss a configuration of oscillator circuit to obtain an extremely low phase noise and an oscillator operating at a non-reactive frequency of SAW resonator.

  • PDF

발전소 변압기 소음저감 대책의 유효성 (The effectiveness of noise reduction devices for transformer noise control of Power Plants)

  • 김연환;김희수;배용채;이현;김성휘
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.1823-1828
    • /
    • 2000
  • Power transformers, air-intakes, stacks in a combined thermal power plant are the main noise sources. Power transformer noise among them has being get a target of public complaint due to 480Hz component of its pure tone. The source is mainly magnetostrictive vibration of the transformer core. The first countermeasures was installing sound barrier on the front of transformer. However, 500Hz, center of the frequency is not reduced. This paper includes the measurements of noise level at the near resident apartment, the identification of noise transfer and the countermeasures for noise sources. Cavity resonance type of noise reduction devices was installed on enclosuring wall of transformers. As a result, the noise level from transformer is reduced about 3dB.

  • PDF

신경회로망 독립성분해석을 이용한 음향센서 기반 대전력기기의 고장진단 알고리즘 (Acoustic Sensors based Fault Diagnosis Algorithm for Large-scaled Power Machines using Neural Independent Component Analysis)

  • 조현철;이진우;이영진;이권순
    • 전기학회논문지
    • /
    • 제57권5호
    • /
    • pp.881-888
    • /
    • 2008
  • We present a novel fault diagnosis methodology using acoustic sensor systems and neural independent component analysis for large-scaled power machines. Acoustic sensors are carried out to measure sounds generated from power machines whose signal is used to determine whether fault is occurred or not. Acoustic measurements are independently mixed and deteriorated from original source signals. We propose a demixing algorithm against such mixed signals by means of independent component analysis which is achieved based on information theory and higher-order statistics to derive learning mechanism.

UNCONVENTIONAL TESTER FOR THE VERIFICATION OF GTO-MODEL-PARAMETERS AND FOR THE INVESTIGATION FO THE CURRENT DENSITY DISTRIBUTION IN GTO TABLETS

  • Henry G ldner;Andreas Thiede;Lutz G hler;Schulze, Hans-Joachim;Jakob Sigg;Johann Otto;Dieter Metzner
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.246-251
    • /
    • 1998
  • This paper describes the main features of an unconventional tester for high power semiconductor devices. Two application ranges are highlighted. The tester is used for the extraction of GTO parameters and their verification by measurements. The second field comprises the determination of the radial and azimuthal current density distribution of a GTO tablet. The results are compared with the carrier lifetime distribution.

  • PDF

선형변환분할 기법에 의한 새로운 상태추정 앨고리즘 개발에 관한 연구 (A Study on the Development of New State Estimation Algorithm by the Decomposition Method of Linear Transformation)

  • 송길영;김영한;최상규
    • 대한전기학회논문지
    • /
    • 제35권4호
    • /
    • pp.148-155
    • /
    • 1986
  • This paper presents a new decoupled power system state estimation method. The decoupling is achieved via simple linear transformation on power measurements in contrast with the modified fast decoupled state estimation method which assumes decoupling by direct negligence of the off-diagonal blocks of the observation functions. The new estimation method is compared with the modified decoupled state estimation method against IEEE-14 bus model power system and 25 bus model power system in several system conditions. It is observed that the proposed method shows better convergence performance and filtering performance than a modified fast decoupled state estimation.

  • PDF

Multilayer Power Delivery Network Design for Reduction of EMI and SSN in High-Speed Microprocessor System

  • Park, Seong-Geun;Kim, Ji-Seong;Yook, Jong-Gwan;Park, Han-Kyu
    • Journal of electromagnetic engineering and science
    • /
    • 제2권2호
    • /
    • pp.68-74
    • /
    • 2002
  • In this paper, a pre-layout design approach for high-speed microprocessor is proposed. For multilayer PCB stark up configuration as well as selection and placement of decoupling capacitors, an effective solution for reducing SSN and EMI is obtained by modeling and simulation of complete power distribution system. The system model includes VRM, decoupling capacitors, multiple power and ground planes for core voltage, vias, as well as microprocessor. Finally, the simulation results are verified by measurements data.