• 제목/요약/키워드: Power measurements

검색결과 1,573건 처리시간 0.026초

수소 난류확산화염에서 NOx 생성특성에 대한 복사분율의 영향 (The Effect of Flame Radiation on NOx Emission Characteristic in Hydrogen Turbulent Diffusion Flames)

  • 김승한;김문기;윤영빈
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2000년도 제21회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.47-58
    • /
    • 2000
  • The relationship among the flame radiation, NOx emissions, residence time, and global strain rate are examined for turbulent non-premixed jet flames with wide variations in coaxial air conditions. Measurements of NOx emission, flame geometry and flame radiation were made to explain the NOx emission scaling based on global parameters such as flame residence time, global strain rate, and radiant fraction. The overall 1/2-power scaling is observed in coaxial air flames, irrespective of coaxial air conditions, but the degree of deviation from the l/2-slope curve in each case differs from one another. From the comparison between the results of pure hydrogen flames and those of helium diluted hydrogen flames, it is observed that flame radiation plays a significant role in pure hydrogen flames with coaxial air and the deviation from 1/2-power scaling may be explained in two reasons: the difference in the flame radiation and the difference in jet similarity in coaxial air flames. From the radiation measurements, more detailed explanations on these deviations were suggested.

  • PDF

적응 필터을 이용한 전력계통의 상태 추정에 관한 연구 (A Study on Power System State Estimation using Adaptive Filter)

  • 박영문;박준호;황창선;정성환;최준혁
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1988년도 추계학술대회 논문집 학회본부
    • /
    • pp.107-110
    • /
    • 1988
  • The quadratic cost function J(x) and the normalized residuals $r_N$ are conventionally used for identifying the presence and location of bed measurements in power system state estimation. These are "post estimation" tests and therefore require the complete re-estimation of system states whenever bed data is identified. This paper presents a pre-filter for reducing errors of the raw measurements using an adaptive filter. Each measurement is processed by the adaptive filter before being used in the state estimation. The performance of the adaptive filter is tested and the results are shown in this paper.

  • PDF

Improved prediction of Pump Turbine Dynamic Behavior using a Thoma number dependent Hill Chart and Site Measurements

  • Manderla, Maximilian;Kiniger, Karl N.;Koutnik, Jiri
    • International Journal of Fluid Machinery and Systems
    • /
    • 제8권2호
    • /
    • pp.63-72
    • /
    • 2015
  • Water hammer phenomena are important issues for the design and the operation of hydro power plants. Especially, if several reversible pump-turbines are coupled hydraulically there may be strong unit interactions. The precise prediction of all relevant transients is challenging. Regarding a recent pump-storage project, dynamic measurements motivate an improved turbine modeling approach making use of a Thoma number dependency. The proposed method is validated for several transient scenarios and turns out to improve correlation between measurement and simulation results significantly. Starting from simple scenarios, this allows better prediction of more complex transients. By applying a fully automated simulation procedure broad operating ranges of the highly nonlinear system can be covered providing a consistent insight into the plant dynamics. This finally allows the optimization of the closing strategy and hence the overall power plant performance.

Electrochemical Lithium Insertion/Extraction for Carbonaceous Thin Film Electrodes in Propylene Carbonate Solution

  • Fukutsuka, Tomokazu;Abe, Takeshi;Inaba, Minoru;Ogumi, Zempachi;Matsuo, Yoshiaki;Sugie, Yosohiro
    • Carbon letters
    • /
    • 제1권3_4호
    • /
    • pp.129-132
    • /
    • 2001
  • Carbonaceous thin films were prepared from acetylene and argon gases by plasma assisted chemical vapor deposition (Plasma CVD) at 873 K. The carbonaceous thin films were characterized by mainly Raman spectroscopy, and their electrochemical properties were studied by cyclic voltammetry and charge-discharge measurements in propylene carbonate (PC) solution. Raman spectra showed that crystallinity of carbonaceous thin films is correlated by the applied RF power. The difference of the applied RF power also affected on the results of cyclic voltammetry and charge-discharge measurements. In PC solution, intercalation and de-intercalation of lithium ion can occur as well as in the mixed solution of EC and DEC.

  • PDF

Lifetime estimation of a covered overhead line conductor

  • Leskinen, Tapio;Kantola, Kari
    • Wind and Structures
    • /
    • 제6권4호
    • /
    • pp.307-324
    • /
    • 2003
  • The paper presents results of studies concerning wind-induced aeolian vibration and fatigue of a 110 kV covered conductor overhead line. Self-damping measurement techniques are discussed: power method is found to be the most reliable technique. A method for compensating tension variations during the self-damping test is presented. Generally used empirical self-damping power models are enhanced and the different models are compared with each other. The Energy Balance Analysis (EBR) is used to calculate the aeolian vibration amplitudes, which thereafter are converted to bending stress for the calculation of conductor lifetime estimate. The results of EBA are compared with field measurements, Results indicate that adequate lifetime estimates are produced by EBA as well as field measurements. Generally the EBA gives more conservative lifetime expectancy. This is believed to result from the additional damping existing in true suspension structures not taken into account by EBA. Finally, the correctness of the line design is verified using Cigre's safe design tension approach.

육류 신선도 판별을 위한 휴대용 전자코 시스템 설계 및 성능 평가 (Design and performance evaluation of portable electronic nose systems for freshness evaluation of meats)

  • 김재곤;조병관
    • 농업과학연구
    • /
    • 제38권3호
    • /
    • pp.525-532
    • /
    • 2011
  • The aim of this study was to develop a portable electronic nose system for freshness measurement of meats, which could be an alterative of subjective measurements of human nose and time-consuming measurements of conventional gas chromatograph methods. The portable electronic system was o optimized by comparing the measurement sensitivity and hardware efficiency, such as power consumption and dimension reduction throughout two stages of the prototypes. The electronic nose systems were constructed using an array of four different metal oxide semiconductor sensors. Two different configurations of sensor array with dimension were designed and compared the performance respectively. The final prototype of the system showed much improved performance on saving power consumption and dimension reduction without decrease of measurement sensitivity of pork freshness. The results show the potential of constructing a portable electronic system for the measurement of meat quality with high sensitivity and energy efficiency.

테라헤르츠 전자기 펄스를 이용한 이산화규소의 전기적 광학적 특성 (The Electrical and Optical Characteristics of Silica Sand by Terahertz Electromagnetic Pulses)

  • 전태인
    • 한국전기전자재료학회논문지
    • /
    • 제14권3호
    • /
    • pp.202-206
    • /
    • 2001
  • Using THz time-domain spectroscopy (THz-TDS), the power absorption, the index of refraction, and the real conductivity of silica sand are measured from 0.1[Thz] to 0.5[Thz] frequency range. It is impossible to measure the characterization of the silica sand by simple electrical measurements using mechanical contacts, e.g., Hall effect or four-point probe measurements. However, the THz-TDS technique can measure not only electrical but also optical characterization of he sample. Also this technique can measure frequency dependent results. Especially, the real conductivity was increased according to THz frequency. This is unusual material compare with metal and semiconductor materials; the measured real conductivity are not followed by the simple Drude theory.

  • PDF

스위치 모드 파워 서플라이에서의 전도 전자파 장애의 시뮬레이션과 분석 (Simulation &Analysis of Conducted EMI in Switched Mode Power Supplies)

  • 이동영;이재호;민승현;조보형
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제50권3호
    • /
    • pp.122-129
    • /
    • 2001
  • Exact simulation of conducted EMI in switched mode power supplies is proposed. In order to achieve exact simulation, PSPICE active component ABM model and modified transformer model are proposed. Each model parameter is extracted from measurements and data-books. PSPICE simulation results with high frequency PCB pattern model are accordant with EMI measurements for a 50[W] isolated flyback converter. EMI relations of each component and EMI patterns are analyzed.

  • PDF

운전중인 고압전동기에서 절연열화 분석 (Analysis of Insulation Aging in Operating High Voltage Motors)

  • 김희동;주영호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 C
    • /
    • pp.2175-2178
    • /
    • 2005
  • During normal machine operation, partial discharge(PD) measurements were performed with turbine generator analyzer(TGA) in five high voltage motors(rated 6.6kV). These high voltage motors were installed with 80pF capacitive couplers at the terminal box. The PD patterns were displayed two dimensional and three dimensional. TGA summarizes each plot with two quantities such as the normalized quantity number(NQN) and the peak PD magnitude(Qm). Off-line PD measurements were conducted on five motors. These motors were energized to 3.81kV. The PD levels in pC were measured with a conventional digital PD detector. The comparison of positive to negative PD indicates whether the defect elements of PD are within the insulation or on the insulation surface. Internal discharges were generated in phase A, B and C of COP-B and pulv.-B, in phase B of Pulv. C and in phase C of Pulv.-D motor. Discharge at conductor surface was discovered in phase A of Pulv. D motor. Slot discharges occurred in three phases of Pulv. E motor.

  • PDF

Environmental Radioactivity at Ko-ri Nuclear Power Plant Site December 1970-November 1972

  • Yang, Kyung-Rin;Pak, Chan-Kirl
    • Nuclear Engineering and Technology
    • /
    • 제5권3호
    • /
    • pp.240-248
    • /
    • 1973
  • 고리에 위치한 원자력발전소 건설부지의 환경방사능의 측정보고이며 1970년 12월부터 1972년 11월 사이에 일광, 월내, 신암, 좌천, 소상 고리등 여섯개 지역에서 채취한 토양, 물, 솔잎, 낙진시료에 대하여 전방사능을 측정하였고 1972년에 채집한 채소류, 해산물 시료에 대하여 Sr-90 Cs-137의 방사능을 측정하였다. 각 시료의 측정처를 보면 그값은 계절적인 변화와 연차적인 감소천상을 나타내 주고 있다.

  • PDF