• 제목/요약/키워드: Power line noises

검색결과 60건 처리시간 0.024초

Filterless and Sensorless Commutation Method for BLDC Motors

  • Rad, Shahin Mahdiyoun;Azizian, Mohammad Reza
    • Journal of Power Electronics
    • /
    • 제18권4호
    • /
    • pp.1086-1098
    • /
    • 2018
  • This study presents a new sensorless commutation method for brushless direct current motors to replace Hall sensor signals with virtual Hall signals. The importance of the proposed method lies in the simultaneous elimination of the phase shifter and the low-pass filters, which makes the method simple and cost-effective. The method removes high ripple switching noises from motor terminals, thereby decreasing motor losses. The proposed method utilizes unfiltered line voltages with notches caused by current commutation. Hence, specific sign signals are defined to compensate for the effects of commutation noise. The proposed method is free from phase delay that originates from low-pass filters. The method directly produces virtual Hall signals, and thus, it can be interfaced with low-cost commercial commutation integrated circuits based on Hall sensors. Simulation and experimental results show the effectiveness and validity of the proposed method.

중대형 리튬폴리머 2차전지용 충방전기 개발 (Design of a cycler system for large capacity lithium-polymer battery)

  • 오동섭;오성업;이종윤;박민호;성세진
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2004년도 전력전자학술대회 논문집(1)
    • /
    • pp.82-86
    • /
    • 2004
  • In this paper, a cycler system for the Lithium-Polymer battery with the large capacity of 120Ah is presented. This system is constituted as the two units for the charging and discharging. The Lithium-Polymer battery should be charged in CC and CV mode, and it is required a very high precision control of the voltage and current for the charging unit. To decrease the switching noises and harmonics, parallel operation method is adopted and utilized in the power conversion module. The discharging unit has a link AC system function to return the discharging energy of battery to AC line and has comparatively less thermal loss. These units are designed to be controlled and monitored by personal computer. The total system for the battery charging and discharging is described and presented.

  • PDF

GIS내부의 부분방전신호 감도개선 및 주파수변환기법에 의한 GIS UHF Sensor 모듈의 외부노이즈차폐기법에 관한 연구 (A Study of the Method for External Noise Shielding using the GIS UHF Sensor Module Applied to the Partial Discharge Signal Sensitivity and Method of Frequency Transforming in the Internal GIS)

  • 이승민
    • 전기학회논문지
    • /
    • 제59권4호
    • /
    • pp.728-732
    • /
    • 2010
  • GIS(Gas insulated switching gear) is power equipment with excellent dielectric strength and is economy merit in high confidence and stability. Recently, because equipment of GIS was occurring problem of confidence used for a long time, partial discharge on-line diagnosis systems have been importantly recognized. Partial discharge (PD) detection is an effective means for monitoring and evaluation of dielectric condition of gas insulated system (GIS). The ultra-high-frequency (UHF) PD detection technique can detect and locate the PD sources inside GIS by detecting electromagnetic wave emitted from PD source. Therefore, real-time diagnostic system using UHF detection method has been developed for this application is being expanded gradually. However, the signal of partial discharge occurring in SF6 gas is very weak and susceptible to external noises which mainly consist of PD in air. Thus, it is important to distinguish the PD in SF6 gas more sensitively from the external noises. Unfortunately, these external noise signals and the partial discharge signals have very similar characteristics. Therefore, to solve this problem, we need the signal processing method for distinguish partial discharge signals with external noise signals for improvement of SNR(signal to noise ratio) and sensitivity. In this paper, we proposed internal signal processing method for removing external noise signals with built-in pre.amplifier and frequency conversion circuit.

Transmission Lines Rights-of-Way Mapping Using a Low-cost Drone Photogrammetry

  • Oh, Jae Hong;Lee, Chang No
    • 한국측량학회지
    • /
    • 제37권2호
    • /
    • pp.63-70
    • /
    • 2019
  • Electric transmission towers are facilities to transport electrical power from a plant to an electrical substation. The towers are connected using wires considering the wire tension and the clearance from the ground or nearby objects. The wires are installed on a rights-of-way that is a strip of land used by electrical utilities to maintain the transmission line facilities. Trees and plants around transmission lines must be managed to keep the operation of these lines safe and reliable. This study proposed the use of a low-cost drone photogrammetry for the transmission line rights-of-way mapping. Aerial photogrammetry is carried out to generate a dense point cloud around the transmission lines from which a DSM (Digital Surface Model) and DTM (Digital Terrain Model) are created. The lines and nearby objects are separated using nDSM (normalized Digital Surface Model) and the noises are suppressed in the multiple image space for the geospatial analysis. The experimental result with drone images over two spans of transmission lines on a mountain area showed that the proposed method successfully generate the rights-of-way map with hazard nearby objects.

전원단자 방해파 측정 오차의 개선 방법 (The method for reducing the measurement errors of power line disturbance)

  • 신국선;최성호;이재향;신호섭;김남;박성욱;김진석
    • 한국전자파학회:학술대회논문집
    • /
    • 한국전자파학회 2002년도 종합학술발표회 논문집 Vol.12 No.1
    • /
    • pp.336-339
    • /
    • 2002
  • CISPR(Committee Internationale Special des Perturbations Radio Electriques) has proposed limits on the noises emitting from power lines and signal lines. But different measurement environment and different measurement methods are used in different countries. This difference causes much confusion in understanding the results measured by different test laboratories. In this paper, we measure EMI noise using the absorbing clamp method that takes short measurement time and is described in CISPR 13, 14-1, 16-2. We analyze the cause of the difference of measurement results.

  • PDF

광전자식 과전류 보호계전기의 구현에 관한 연구 (Implementation of Optoelectric Over Current Relay)

  • 박병석;오면택;이화준;조홍근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 E
    • /
    • pp.1846-1849
    • /
    • 1998
  • An optical magnetic filed sensor, YIG (Yittrium Iron Garnet), response rapidly, to the power-line currents to be measured. In response to Faraday effect, it shows wide-and-linear measurable range. This paper reports the development and implementation of an OOCR (Optoelectric OverCurrent Relay) using this sensor. This relay is free from environmental electro-magnetic noises and has excellent insulation characteristics inherently. By using this OOCR, we can reduce insulation cost of protective relaying systems and its maintenance cost, and can achieve high reliability of the system.

  • PDF

저전류 영역에서 로고우스키 코일 특성 (Characteristics of Rogowski coil at Low Cutrrent Region)

  • 박정남;이강원;이청;김길수;박영국;강성화;임기조
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 연구회
    • /
    • pp.47-50
    • /
    • 2001
  • Conventionally, air-cored Rogowski coil was designed for use as high alternating and transient current sensor without saturation caused by ferromagnetic material in its core. This paper investigated that Rogowski coil can be applied to low current measurement in 60Hz power line. Measured parameters R, L of coil were compared with theoretically calculated values. Output voltages crossed by Rogowski coil have shown some linearity according to input current(tens to thousands of amperes) passing through it. And also shielding effect for external noises was investigated for three cases.

  • PDF

Intelligent fuzzy weighted input estimation method for the input force on the plate structure

  • Lee, Ming-Hui;Chen, Tsung-Chien
    • Structural Engineering and Mechanics
    • /
    • 제34권1호
    • /
    • pp.1-14
    • /
    • 2010
  • The innovative intelligent fuzzy weighted input estimation method which efficiently and robustly estimates the unknown time-varying input force in on-line is presented in this paper. The algorithm includes the Kalman Filter (KF) and the recursive least square estimator (RLSE), which is weighted by the fuzzy weighting factor proposed based on the fuzzy logic inference system. To directly synthesize the Kalman filter with the estimator, this work presents an efficient robust forgetting zone, which is capable of providing a reasonable compromise between the tracking capability and the flexibility against noises. The capability of this inverse method are demonstrated in the input force estimation cases of the plate structure system. The proposed algorithm is further compared by alternating between the constant and adaptive weighting factors. The results show that this method has the properties of faster convergence in the initial response, better target tracking capability, and more effective noise and measurement bias reduction.

전원선에서의 광대역 EMC 필터의 설계 및 제작 (Design and Fabrication of Broad-Band EMC Filter for Power Line)

  • 김동일;구동우;양은정;김도연;예병덕
    • 한국항해항만학회지
    • /
    • 제26권5호
    • /
    • pp.525-528
    • /
    • 2002
  • 제안된 EMC 필터는 높은 투자율의 페라이트 비드와 관통형 콘덴서로 구성하여 제작하였고, 10 MHz ~ 1.5 GHz에서 전원선에서 광대역 노이즈 신호에 대한 EMC 요구를 만족시킨다. 최적의 필터를 설계하기 위하여 페라이트 비드의 임피던스를 계산하여 찾았다. 그 결과, 광대역 EMC 필터는 차동모드 노이즈와 공통모드 노이즈에 대해 10 MHz ~ 1.5 GHz대역에서 30 dB 이상의 필터 특성을제안된 EMC 필터는 높은 투자율의 페라이트 비드와 관통형 콘덴서로 구성하여 제작하였고, 10 MHz ~ 1.5 GHz에서 전원선에서 광대역 노이즈 신호에 대한 EMC 요구를 만족시킨다. 최적의 필터를 설계하기 위하여 페라이트 비드의 임피던스를 계산하여 찾았다. 그 결과, 광대역 EMC 필터는 차동모드 노이즈와 공통모드 노이즈에 대해 10 MHz ~ 1.5 GHz대역에서 30 dB 이상의 필터 특성을 나타내었다. 그리고, DC ~ 1.8 GHz 주파수 대역에서 10 ~ 30 dB이상의 내성 특성을 향상시켰다. 나타내었다. 그리고, DC ~ 1.8 GHz 주파수 대역에서 10 ~ 30 dB이상의 내성 특성을 향상시켰다.

태양광발전 연계 시스템에 의한 PWM 전류형 인버어터에 관한 연구 (A study on the PWM(pulse witdh modulation) current source Inverter with utility)

  • 황락훈;최호규;신양호;이춘상;김주래;조상로;조문택
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 B
    • /
    • pp.1020-1022
    • /
    • 2001
  • because the output of solar cell is direct, it is necessary to install D/A converter system for A.C load, and in case of driving utility line system, it is possible to drive system relation when the system supplies sinusodal current ant voltage having unit power factor. As the characteristics of the soar cell output the is influenced by dailysunight charge, for more electric power it is essential to control the direction toward the san so that the driving point of solar cell can always operate near maximum output point. PWM modulation device among electric power converters must have stable modulation at anytime when it includes noise-factors such as noise-wave and noises on electric voltage wave, a synchronous signal system. In dealing with synchronous signal for control and control signal by microprocessor, it is necessary to compensate it because there is time difference between sample paint and carrier wave. On this papers, single phase PWM current type invertor controled the solar cell having typical voltage dropping character has optimun short current in short, reduces D.C reactance, composes controller for modulation and keeps lower harmonic and high power factor keeping maximum output of solar cell according daily sunlight charge variation.

  • PDF