• Title/Summary/Keyword: Power line noises

Search Result 60, Processing Time 0.031 seconds

Analysis of Power Line Characteristics as High Speed Communication Channel (고속 채널로써 전력선 특성 분석)

  • Park, Chong-Yeun;Jo, Ho-Chan;Lee, Hyeuk-Sun
    • Journal of Industrial Technology
    • /
    • v.21 no.A
    • /
    • pp.207-211
    • /
    • 2001
  • For the power line communication, we studied its characteristic impedance, noise characteristics, loss characteristics and the coupling circuit between the communication MODEM and power lines. As the results of the experiments, we concluded that the power line impedance in a house varied in the wide range because the electric systems generate the current and voltage hamornic noises.

  • PDF

Performance of a Multi-Code CDMA Scheme on Non-Gaussian Noises in Power Line Communication Channels

  • Na, Sung-Ju;Yoan Shin
    • Proceedings of the IEEK Conference
    • /
    • 2000.07a
    • /
    • pp.132-135
    • /
    • 2000
  • In this paper, we propose to exploit a multi-code CDMA scheme for power line communication (PLC) systems, and its performance on non-Gaussian impulse and harmonic noises is presented. The proposed multi-code CDMA scheme utilizes convolutional coding and block interleaving to combat with the non-Gaussian noises, and simulation results indicate effective alleviation of these noises, and thus significant bit error rate improvement by the proposed scheme even under strict restriction of frequency band allowed in PLC systems.

  • PDF

The Originating Characteristics of Periodic Impulse Noises in the Data Communication System by Distribution Line Carrier Method (배전선반송 데이타통신에서의 주기적 임펄스노이즈의 발생특성)

  • 최순만;노창주
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.18 no.2
    • /
    • pp.75-82
    • /
    • 1994
  • The existence of peroodic impulse noises in distribution line carrier (DLC) communication system is known to be the most serious obstacle for improving DLC communication quality in reliability and capacity. From the spectral points, impulse noises can be divided into baseband type and modulation type the noise width of whichs are much different each other. With each nose type, this study presents the basic characteristics in relation to what they originate from and how their spectrum properties are revealed. The baseband type impulse noise is normally caused from thyristor circuit running with low switching speed and the modulation type noise from the circuit of switching power supply. The base wave of modulation noise is shown to be the pulsuatic charging current to primary condenser in switching power circuit. The study result indicates also that placing the DLC carrier frequency away the band predominated by modulated noise especially from RCC type switching power circuit is very important in DLC design.

  • PDF

Performance Analysis of Direct-Sequence Spread Spectrum(DSSS) System in Power Line Communications (전력선통신에서 직접확산 스펙트럼(DSSS) 계의 성능 분석)

  • Suh, Heejong;Zhou, Xiaozheng
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.41 no.11
    • /
    • pp.25-32
    • /
    • 2004
  • In this paper, we first analysed the ability of DSSS resistance against noises, which are main interferences to the four types in power line communications. Based on the characteristic of these noises, we made a noise source of power line which is similar with the result measured, in practice. We simulated and analysed the BER performance of BPSK with DSSS over this noise model and one without the DSSS, for comparison. Result showed that the BPSK with DSSS system has improved by 8 dB, as compared to those without the DSSS, as against power line noises.

Baseline Drift Reduction and Suppression of Power Line Noises in ECG Signal by Designing Multirate Digital Filter (다중레이트 디지털 필터 설계 및 심전도 신호의 기저선 변동 및 전원 잡음 제거)

  • Kim, Jeong-Hwan;Kim, Hyun-Tae;Park, Sang-Eun;Lee, Jeong-Whan;Kim, Kyeong-Seop
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.4
    • /
    • pp.551-558
    • /
    • 2014
  • Baseline drift reduction and removal of power line noises in electrocardiogram are often necessary to avoid the distortions in extracting the fiducial features. With this aim, the multirate digital filtering algorithm is suggested to design and implement Finite Impulse Response or Infinite Impulse Response Filter by changing the sampling rate with omitting or interpolating intermediate ECG data. After the experimental simulations performed, we can conclude the fact that we can suppress the baseline wander and power line disturbances in ECG signal with reducing the computational complexities in which we do not keep the original and high sampling frequency.

Development of the equipment for detecting the poor power facilities by receiving electric noises (전자파 잡음을 이용한 전기설비 불량 검출장치 개발)

  • 이복규;강성철
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.1356-1359
    • /
    • 1997
  • There are various methods to detect the faulty electric facilities(esp, insulator) indirectly on power distribution lines at a certain distance apart. This paper describes the proto type equipment to detect a faulty insulator by receiving a electric discharge noises, which are generated with a periodicity of 120Hz.

  • PDF

New Resonant AC Link Snubber-Assisted Three-Phase Soft-Switching PWM Inverter and Its Comparative Characteristics Evaluations

  • Yoshida, Masanobu;Hiraki, Eiji;Nakaoka, Mutsuo
    • Journal of Power Electronics
    • /
    • v.3 no.4
    • /
    • pp.239-248
    • /
    • 2003
  • This paper presents a novel prototype of three-phase voltage source type zero voltage soft-switching inverter with the auxiliary resonant snubbers suitable for high-power applications with IGBT power module packages in order to reduce their switching power losses as well as electromagnetic conductive and radiative noises. A proposed single inductor-assisted resonant AC link snubber circuit topology as one of some auxiliary resonant commutation snubbers developed previously to achieve the zero voltage soft-switching (ZVS) for the three-phase voltage source type sinewave PWM inverter operating under the instantaneous space voltage vector modulation is originally demonstrated as compared with the other types of resonant AC link snubber circuit topologies. In addition to this, its operation principle and unique features are described in this paper. Furthermore, the practical basic operating performances of the new conceptual instantaneous space voltage vector modulation resonant AC link snubber-assisted three-phase voltage source type soft-switching PWM inverter using IGBT power module packages are evaluated and discussed on the basis of switching voltage and current waveforms, output line to line voltage quality, power loss analysis, actual power conversion efficiency and electromagnetic conductive and radiative noises from an experimental point of view, comparing with those of conventional three-phase voltage source hard-switching PWM inverter using IGBT power modules.

A Study on Possibility of Detection of Insulators' Faults by Analyses of Radiation Noises from Insulators (애자의 소음 분석을 통한 애자 고장 탐지 가능성 연구)

  • Park, Kyu-Chil;Yoon, Jong-Rak;Lee, Jae-Hun
    • The Journal of the Acoustical Society of Korea
    • /
    • v.28 no.8
    • /
    • pp.822-831
    • /
    • 2009
  • The porcelain insulators are important devices, that are used to isolate electrically and hold mechanically in the high-voltage power transmission systems. The faults of the insulators induce very serious problems to the power transmission line. In this paper, we introduce techniques for fault detections of insulators by acoustic radiation noises from them. We measured radiation noises from normal state insulators and fault state insulators. The used insulators were two different type porcelain insulators, a cut out switch, two different type line posters, and a lightning arrester. Each results was compared each other in time domain, frequency domain and filter banks' outputs. We found the possibility of detection of insulators' faults and also suggested techniques for fault detections.

Power Line Communication-based Heated Glass Temperature Control System (전력선통신을 이용한 선박 및 건축용 발열유리 온도제어 시스템)

  • Lee, Su-Hyeong;Kim, In-Dong
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.20 no.2
    • /
    • pp.105-114
    • /
    • 2015
  • Heated glasses are widely used to prevent surface condensation and freezing in ship and building windows. This study proposes a heated glass temperature control system composed of power and control circuits to control the temperature of heated glasses. The proposed temperature control system adopts a digital controller instead of a conventional analog controller. Thus, the proposed system has better characteristics, such as precise setup and control of glass temperature, setup and control of output power, and control mode change between ON/OFF and phase controls. The system can also implement multi-functional control algorithms. The control characteristics are not dependent upon external disturbances, such as ambient temperature and electrical noises. Furthermore, the proposed temperature control system utilizes the power line communication (PLC) method to control the number of heated glasses without any extra communication lines. The system proposes a new communication protocol with strong immunity to electrical switching noises. A new sensorless algorithm is used to detect the temperature of the heated glass. This study presents the design guidelines in detail and its effectiveness are confirmed by implementing a 4-kw prototype temperature control system.

Filter Test for Partial Discharge Detection of Underground Distribution Cables (지중배전케이블의 PD 검출용 필터 시험 연구)

  • Lee, Yong-Sung;Kim, Jung-Yoon;Lee, Kwan-Woo;Choi, Yong-Sung;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.215-216
    • /
    • 2005
  • To decrease and remove of much noises that is detected in PD (partial discharge) measuring test. we forced on detection of those. We made W-LC filter for measuring PD. which adapted that to field test. We tested after design laboratory circumstances like field line. and then the phase change properties of detected signal in UHF sensor were measured by Lemke Probe and oscilloscope (TDS-3054. Tektronix). Eventually we checked decrement of noises from experimental result. Also from experimental result at the joint box of 22.9[kV] distribution line. we obtained reasonable data which enable noises to decrease. Hereafter those results will be adapted at ultra-high voltage for trouble prevention and on-line cable watch. diagnosis of those.

  • PDF