• Title/Summary/Keyword: Power line modem

Search Result 127, Processing Time 0.033 seconds

Dimming Control system Using Power Line Modem (전력선 통신을 이용한 조광제어 시스템)

  • 주병훈
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.107-110
    • /
    • 2000
  • 전력선 통신을 이용한 조광제어 시스템은 전자식 안정기의 주파수 변조 방식을 잉요하여 실시하였다 전력선 통신제어 사용된 data 변조 방식은 FSK 방식을 이용하였으며 안정기의 스위칭 동작에 의해 발생하는 EMI는 140kHz 대역의 노이즈를 발생시키므로 본논문에서는 2단 필터를 사용하여 해당 대역의 EMI 60dB 감쇄시켰다.

  • PDF

Implementation of PLC modem using DS/SS for Automation (자동화를 위한 DS/SS 방식의 전력선 모뎀 구현)

  • 박준용;최원호;노경호;박종연
    • Proceedings of the IEEK Conference
    • /
    • 2003.07a
    • /
    • pp.493-496
    • /
    • 2003
  • This paper studied the method to improve the reliability with the simple structure and the decreased calculation of Micro-Controller(uC) in Power Line Modem. We have implementation the program which correct the 1-bit error of the $\mu$C within the control system and the DS/SS(Direct sequence/spread spectrum) by adding the simple circuit between a single chip powerline transceiver IC and a uC.

  • PDF

Method and implementation for reducing standby power consumption in intermediate capacity power supply with Power Line Communication (전력선통신기능 적용 중.대용량 전원공급장치의 대기전력 절감방법 및 구현)

  • Son, Do-Sun;Kim, Ki-Hyun;Kim, Sang-Cheol;Jeon, Eui-Seok;Lee, Sang-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1947-1948
    • /
    • 2008
  • This paper presents the implementation of Power Line Communication(PLC) module which can reduce standby-power consumption. The suggested PLC module consists of PLC modem, coupling circuit, ZCP(Zero-Cross Point) Circuit and main SMPS control relay. The test results under power line communication test-bed used home appliance show the 77% saving of standby-power.

  • PDF

Lighting Dimming Control system using PLC (전력선 통신을 이용한 방전등의 조광제어 시스템)

  • 김한수;박종연
    • Proceedings of the IEEK Conference
    • /
    • 2001.06e
    • /
    • pp.157-160
    • /
    • 2001
  • We studied about the lighting control system on pc using PLM(Power Line Modem). The PLM is composed of FSK IC-chip and the circuit for the power line communication. We developed the control program using visual c++ language on PC for dimming the lamps. In this paper dimming controller was made with PIC161F874 and its communication speed was 1200 boad rates.

  • PDF

Development of Remote Load Management System Using PowerLine Communication (전력선 통신을 이용한 원격부하관리시스템 개발)

  • Na, Chae-Dong;Lee, Sung-Bum;Jeong, Eull-Gi
    • Proceedings of the KIEE Conference
    • /
    • 2002.06a
    • /
    • pp.149-152
    • /
    • 2002
  • In this paper, an simple load management system was introduced. This system is composed of Main Controller, DTU(Dispersion Terminal Unit), Power Line Modem and HMI (Human Machine Interface) program. To control distant loads, network function using powerline communication is implemented in DTU, with HMI program, the untrained users are able to operate system easily. Additionally using the Powerline, the cost and time of installation is saved. The system performance was proved in a several experiments.

  • PDF

Energy Saving Heating Control System Using the Power Line Communication Modem for a Valve Controller (밸브제어기용 전력선 통신 모뎀을 이용한 에너지 절약형 난방제어 시스템)

  • Kim, Myung-Ho;Lee, Tae-Bong
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.55 no.3
    • /
    • pp.123-127
    • /
    • 2006
  • In a heating control system, the indoor temperature controller transfers temperature signals inputted from the temperature sensor and the user to the valve controller. The valve controller receives these signals then the valve controller controls the valve driving motor on two position control and controls the indoor temperature. When setting up a new valve driving motor from a long distance it is necessary to set up a new valve controller. But occasionary, due to construction, It is impossible to wire between the existing valve controller and the new valve controller. In this situation, the new and existing valve controllers can communicate via power line communication. In this paper it is proposed heating control system controls on two position control via power line communication.

Development of On-Line Partial Discharge Monitoring System in High Voltage Motors (고압전동기 운전중 부분방전 감시 시스템 개발)

  • Kim, Hee-Dong;Kong, Tae-Sik;Ju, Young-Ho
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.1175-1178
    • /
    • 2004
  • On-line partial discharge(PD) monitoring system has been developed to monitor in operating large motor stator insulations. This system makes use of remote diagnosis techniques for the evaluation of PD activity in the control center of thermal power plant. This system can be remotely accessed via a modem to build database, analyze status and interpret the pattern of PD activity. A personnel computer is generally connected to ten motors to continuous measurement of the PD activity. The test data can be easily interpreted by a maintenance staff. For assessing the condition of stator winding in motors, this system ensures a reliable measurement and accurate estimation. Capacitive couplers used for on-line PD measurement have been 80pF. The maximum PD magnitude(Qmax), PD pattern and normalized quantity number(NQN) were performed by this system.

  • PDF

Development of Demand Controller Using Power line

  • Kim Ho;Kwak Dong-Hyun;Lee Jeong-Bok;Seok Won-Youp;Han Seong-Ryong;Jeon Hee-Jong
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.552-555
    • /
    • 2001
  • In this paper, an intelligent demand control system was introduced. This system are composed of demand controller, RTU, power line modem and HMI program. The proposed demand controller was capable of synchronizing with watt-hour meter recommended by KEPCO(Korea Electrical Power Corporation). To control remote loads, network function using powerline communication is implemented in RTU with HMI program and novices are able to operate system easily. Additionally using the power line, the cost and time of installation can b saved. The system performance was proved with a several experiments.

  • PDF

A Study on the Implementation of Power Line Modem for Remote Control Using DSP (DSP를 이용한 원격 제어용 전력선 모뎀 구현에 관한 연구)

  • Kim Su Nam;Kang Dong Wook;Kim Ki Doo;Yoo Hyeon Joong
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.10C
    • /
    • pp.1433-1443
    • /
    • 2004
  • The power line modem proposed in this paper transmits the remote control signal using CSK(Code Shift Keying) and DS/SS method. The CSK technique provides the increased capacity of transmission and robustness towards noise. Besides, the DS/SS technique provides protection against narrow-band Gaussian interference and multi-path interference. The modem supports full-duplex communication using FDD(Frequency Division Duplex) and the modem structure for forward link is same with that for reverse link. To switch each sub-controlled unit smoothly, 4/$\pi$-DQPSK is adopted for noncoherent demodulation. The PN code for spreading spectrum seues to divide each group which consists of sub-controlled units and Walsh code is used for the M-ary CSK technique. Each block is designed and verified with TMS320C5402 DSP. We show the superiority of the proposed method by analyzing numerically the system performance for the factors of the DS/SS and CSK method ullder additive white Gaussian noise and PBI.

A study on the channel modeling for power line communication (전력선 통신 채널 모델링에 관한 연구)

  • Jeong Young-Hwa
    • The Journal of Information Technology
    • /
    • v.6 no.3
    • /
    • pp.1-10
    • /
    • 2003
  • This paper is concerned with a power line channel modeling for the more fast and efficiently power line communication experiment. A capacitor load channel simulator is a essential equipment in the power line modem development for in-house network. We accomplished a channel modelling by the frequency response method about the total 298 capacitor load channels. This channel data is acquired by the capacitor load simulator modeling a real power line channel environment. When the experiment results acquired from the capacitor load simulator were compared with the result from a channel filter, we confirmed to substitute capacitor load experiments on the actual power line communication without big error.

  • PDF