• Title/Summary/Keyword: Power line communication

Search Result 992, Processing Time 0.058 seconds

Characteristics Analysis of Powerline Channel for Powerline Communication (전력선 통신을 위한 채널 특성 분석)

  • Lee, J.H.;Seo, J.W.;Lee, J.J;Shin, M.C.;Sung, N.H.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.558-560
    • /
    • 2000
  • The role of power line is not limited to providing electrical power. Power line fumed out to be an candidate to cope with the existing communication channels. It is need to be measured the properties of power line as communication channels, before successful communication system is possible. This paper presents the characteristics of power line noise and attenuation measurements in the frequency range of $0{\sim}10$ MHz, and then suggests applicable communication techniques in brief. Power line channel is configured in our laboratory and the length of it is 250 meters.

  • PDF

A Signal Anti-reduction System for Power Line Communication

  • Ko Jong-Sun;Kim Hyun-Sik;Hong Soon-Chan
    • Journal of Power Electronics
    • /
    • v.4 no.4
    • /
    • pp.256-260
    • /
    • 2004
  • A new communication system is suggested using a single-phase full-bridge inverter with high efficiency ferrite core for power line communication (PLC). The conventional system has a decreasing signal voltage problem due to internal resistance. The proposed system has almost zero internal impedance and replaces a linear amplifier.

Machine Learning-Based Signal Prediction Method for Power Line Communication Systems (전력선 통신 시스템을 위한 머신러닝 기반의 원신호 예측 기법)

  • Sun, Young Ghyu;Sim, Issac;Hong, Seung Gwan;Kim, Jin Young
    • Journal of Satellite, Information and Communications
    • /
    • v.12 no.3
    • /
    • pp.74-79
    • /
    • 2017
  • In this paper, we propose a system model that predicts the original signal transmitted from the transmitter using the received signal in the power line communication system based on the multi - layer perceptron which is one of the machine learning algorithms. Power line communication system using communication system using power network has more noise than communication system using general communication line. It causes a problem that the performance of the power line communication system is degraded. In order to solve this problem, the communication system model proposed in this paper minimizes the influence of noise through original signal prediction and mitigates the performance degradation of the power line communication system. In this paper, we prove that the original signal is predicted by applying the proposed communication system model to the white noise environment.

Calculating Mutual Impedance between Power-Line and Communication-Line with Earth Return Current (대지귀로 전류에 의한 전력선과 통신선의 상호임피던스 해석)

  • Lim, Yong-Hun;Hyun, Duck-Hwa
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.269-271
    • /
    • 2003
  • A method for calculation of mutual inductance from the parallel power-line and earth conduct to communication-line is studied in the paper. The solution for the electromagnetic field produced by an overhead power-line is derived using Maxwell's equations and treating the as a boundary value problem. Total mutual inductance from direct current and image current to communication-line is used Carson's formula for infinitely long parallel conductors.

  • PDF

Security Monitoring System for Apartment House Building Using Paver Line Carrier (전력선 통신을 이용한 집단주택 안전관리 시스템)

  • Kim, In-Soo;Kim, Kwan-Ho;Kim, Yo-Hee
    • Proceedings of the KIEE Conference
    • /
    • 1993.07a
    • /
    • pp.476-478
    • /
    • 1993
  • Instead of installing new communication wiring to each house in the apartment house building. the power distribution network. which is already installed in the building. can be use as communication medium. In a safty management, by adoption of power line communication system, at remote we can monitor safty related sensors such as fire, gas leakage, burglar intrusion and emergency call which are located at each house. From this viewpoint, we developed security monitoring system for apartment house building using power lines. Security monitoring system consists of Power Line Communication-Sub Controller (PLC-SC). Power Line Communication-Main Controller (PLC-MC) and Management System (MS). Between a PLC-MC and a PLC-SC, the transmission rate is 1200 bps in power lines and modulation technique is frequency shirt keying (FSK). In between a PLC-MC and a MS, the transmission rate is 1200 bps in communication line (RS-485). As a result of this research. transmission loss is 0.1dB per meter of intrabuilding distribution network. Transmission can be reach in 250 meters. So it is enough to communicate for security monitoring system in apartment house building.

  • PDF

Design of Power Line Communication Protocol using Polling Concept (Polling을 이용한 전력선 통신(PLC) 프로토콜의 설계)

  • Lim, Eun-Jeong;Kang, Cheoul-Shin
    • Proceedings of the IEEK Conference
    • /
    • 2005.11a
    • /
    • pp.31-34
    • /
    • 2005
  • In this paper, we proposed a MAC protocol which can be used in power line communications(PLC). In the power line communication network, the data signal cannot travel long distance because of a serious attenuation. Consequently, we need to have a number of repeaters (amplifiers) in order to recover the signal power, which causes flooding problem in the network The proposed MAC protocol uses polling concept and solves the flooding problem in the power line communication network. The proposed protocol can be applied to power line communication networks for automatic power distribution control system. A mathematical analysis has been carried out to estimate the performance of the proposed protocol.

  • PDF

Propagation Tendency of Lightning Surge in the Power and Communication System (전원 및 신호시스템에서의 뇌서지 전파양상)

  • Lee, Tae-Hyung;Cho, Sung-Chul;Eom, Ju-Hong
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.05a
    • /
    • pp.245-249
    • /
    • 2007
  • The tendency of lightning surge to propagate displays the difference for applicable power and equipment. However, looking into the subject equipment with the lightning surge, the lightning surge can be divided in between the two lines of power, between the power line and the ground, the power line and the PE conductor, between the neutral line and the ground and the like. In addition, in the event of the communication equipment, there exists the case of lightning surge entered from the power line in addition to the entry between the communication lines, the communication line and the ground. In this study, the tendency of propagation of lightning surge penetrated on to the subject equipment is analyzed through the empirical experiment in accordance with the ground method by using the independent ground, common ground, bypass arrester and others among the techniques for safety improvement in power lines.

  • PDF

The Design and Characteristics of the Line Coupler for Power Line Modem (전력선 모델을 위한 Line-Coupler의 설계 및 특성)

  • Park, Chong-Yeun;Cho, Gye-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 1999.07g
    • /
    • pp.3132-3134
    • /
    • 1999
  • To realize the power line communication system, the line coupler is one of the most important systems, which must be adjustable to the power line characteristics. In this paper, three kinds of line couplers were designed and simulated with the Pspice, which could be useful to the power line communication systems in C-Band(95kHz-148.5kHz) frequency

  • PDF

Turbo Coded OFDM Scheme for a High-Speed Power Line Communication (고속 전력선통신 시스템의 터보 부호화)

  • Lee, Jae-Sun;Kim, Yo-Cheol;Kim, Jung-Hui;Kim, Jin-Young
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2009.08a
    • /
    • pp.190-196
    • /
    • 2009
  • In this paper, performance of a turbo-coded OFDM system is analyzed and simulated in a power line communication channel. Since the power line communication system typically operates in a hostile environment, turbo code has been employed to enhance reliability of transmitted data. The performance is evaluated in terms of bit error probability. As turbo decoding algorithms, MAP (maximum a posteriori), Max-Log-MAP, and SOVA (soft decision Viterbi output) algorithms are chosen and their performances are compared. From simulation results, it is demonstrated that Max-Log-MAP algorithm is promising in terms of performance and complexity. It is shown that performance is substantially improved by increasing the number of iterations and interleaver length of a turbo encoder. The results in this paper can be applied to OFDM-based high-speed power line communication systems.

  • PDF

Cable Identification Technology based on Power Line Communication (전력선 통신을 활용한 케이블 식별 기술)

  • Byun, Hee-Jung;Choi, Sang-jun;Shon, Sugoog
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.05a
    • /
    • pp.880-883
    • /
    • 2015
  • Power-line communication technology is proposed to identify cables of power distribution systems. It can extend the application area of power-line communication. Distribution line cable circuits have only a limited ability to carry higher frequencies. Typically power transformers in the distribution system prevent propagating the higher frequency carrier signal. The proposed method uses the limited propagation ability to identify the cable. A novel power cable identification system is designed and implemented. The system consists of a transmitter and a receiver with power-line communication module. Some experiments are conducted to verify the theoretical concepts. Also some simulations are done to help and understand the concepts by using Simulink simulator.

  • PDF