• Title/Summary/Keyword: Power line

Search Result 6,044, Processing Time 0.036 seconds

Implementation of Ship Area Network NMEA protocol Bridge Based on Power Line Communication (전력선통신 기반의 선박용 M모A 프로토콜 브릿지 구현)

  • Kim, Gwan-Hyung;Kang, Sung-In;Jeon, Jae-Hwan;Kwon, Oh-Hyun;Oh, Am-Suk;Cho, Hyun-Cheol
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.11
    • /
    • pp.2419-2422
    • /
    • 2010
  • The current marine internal communication systems are usually composed of NMEA0183, NMEA2000, and MiTS protocols which are located on the physical layer based on RS-422, RS-485, CAN, and EtherNet. However, general vessel communication method have a weak point that must establish the extra private line. But, the power line communication has advantage over general vessel communication method as it uses AC220V/DC24V without changing line. Therefore, we will propose a new bridge based on the DC-PLC(power Line communication) technique which support the NMEA0183 protocol inside vessel network systems.

Single Line-to-ground Fault Location and Information Modeling Based on the Interaction between Intelligent Distribution Equipment

  • Wang, Lei;Luo, Wei;Weng, Liangjie;Hu, Yongbo;Li, Bing
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.5
    • /
    • pp.1807-1813
    • /
    • 2018
  • In this paper, the fault line selection and location problems of single line-to-ground (SLG) fault in distribution network are addressed. Firstly, the adaptive filtering property for empirical mode decomposition is formulated. Then in view of the different characteristics showed by the intrinsic mode functions(IMF) under different fault inception angles obtained by empirical mode decomposition, the sign of peak value about the low-frequency IMF and the capacitance transient energy is chosen as the fault line selection criteria according to the different proportion occupied by the low-frequency components. Finally, the fault location is determined based upon the comparison result with adjacent fault passage indicators' (FPI) waveform on the strength of the interaction between the distribution terminal unit(DTU) and the FPI. Moreover, the logic nodes regarding to fault line selection and location are newly expanded according to IEC61850, which also provides reference to acquaint the DTU or FPI's function and monitoring. The simulation results validate the effectiveness of the proposed fault line selection and location methods.

Numerical Simulation on the Temperature Distribution by Ventilation Type during Heat of the Power line in Electric Power Tunnel (전력구 터널 내 전력선 발열 시 환기방식에 따른 온도분포에 대한 전산해석)

  • Lee, Ho-Hyung;Lee, Seung-Chul;Kwak, Dong-Kurl;Baek, Doo-San
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.3-4
    • /
    • 2014
  • Power line in electric power tunnel generate heat around during power transmission. Rising temperature inside the electric power tunnel reduces the transmission efficiency of the power line. In this study, trying to understand the change in temperature in the electric power tunnel by forced ventilation and natural ventilation when the temperature rise of the electric power tunnel. The results show that average temperature in electric power tunnel by natural ventilation, forced ventilation is $56.55^{\circ}C$, $23.25^{\circ}C$. Therefore electric power tunnel during power transmission needs cooling or ventilation system.

  • PDF

Development of the separated transmission and reception Line Coupler using GIC for Power Line Communication (GIC를 이용한 전력선통신용 송수신 분리형 라인커플러의 개발)

  • 최원호;박준용;박종연
    • Proceedings of the IEEK Conference
    • /
    • 2003.07a
    • /
    • pp.238-241
    • /
    • 2003
  • The purpose of this study is to improve the frequency response of the Line coupler for Power Line Communication. We separate transmission and reception line coupler and design the reception line coupler using GIC. It was found from the result that separation transmission and reception line coupler using GIC have the advantage of a design and high Q.

  • PDF

Synchronization of Chaos Circuit (카오스 회로 동기화)

  • Bae, Young-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2000.07d
    • /
    • pp.2404-2406
    • /
    • 2000
  • Chua's circuit is a simple electronic network which exhibits a variety of bifurcation and attractors. The circuit consists of two capacitors, an inductor, a linear resistor, and a nonlinear resistor. In this paper, a transmitter and a receiver using two identical Chua's circuits are proposed and synchronizations of a T or ${\pi}$ type power line are investigated. Since the synchronization of the power line system is impossible by coupled synchronization, theory having both the drive-response and the coupled synchronization is proposed. As a result, the chaos synchronization has delay characteristics in the power line transmission system caused by the line parameters L and C

  • PDF

Development of Power Line Interphone by the Amplitude Modulation Techniq (전력선을 이용한 AM방식의 인터폰 개발)

  • Park, Jong-Yeun;Kang, Do-Hyung;Choi, Won-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2001.07d
    • /
    • pp.2597-2599
    • /
    • 2001
  • This paper has developed the power line interphone system with the amplitude modulation technique. We described the Amplitude modulation and demodulation circuit and the line coupler for the implementation of the power line interphone. and suggested the experimental result for the signal attenuation, demodulated signal, spectrum.

  • PDF

Relationship Between Urinary Melatonin Levels and Extremely Low Frequency Magnetic Fields for the Selected Primary Schoolchildren Living Nearby and Away from Overhead Transmission Power Line (송전선로 주변과 비주변 초등학생을 대상으로 극저주파 자기장 노출과 뇨중 멜라토닌 분비량간의 상관성 연구)

  • Cho, Yong-Sung;Kim, Yoon-Shin;Lee, Jong-Tae;Hong, Seung-Cheol;Jang, Seong-Ki
    • Journal of Environmental Health Sciences
    • /
    • v.30 no.3
    • /
    • pp.191-206
    • /
    • 2004
  • The present study investigated the hypothesis that a extremely low frequency magnetic field partially suppresses the synthesis of melatonin in a group of 28 primary schoolchildren living nearby and 60 primary schoolchildren aged 12 years living far away from overhead transmission power lines from December 2003 to April 2004 in Seoul, Korea. The mean personal exposure levels of the primary schoolchildren living nearby overhead transmission power line were 0.37 ${\mu}$T, whereas the value for the primary schoolchildren living away from overhead transmission power line 0.05 mT. From simple analyses, the mean melatonin levels in the primary schoolchildren living nearby were lower than away from overhead transmission power line, but not statistically significant differences in the levels of the melatonin (p=0.2421), whereas the statistically significant differences in the levels of the melatonin related to the distance from residence to power line less and more than 100 m by cut-off point (p=0.0139). In multiple linear regression analyses, distance from residence to power line (p=0.0146) and dietary habit about burned meat (p=0.0170) proved to be significant risk factors in the mean nocturnal melatonin levels in the primary schoolchildren. In conclusion, these results demonstrate that urinary levels of nocturnal melatonin are not altered in primary schoolchildren exposed to extremely low frequency magnetic field(ELF-MF) at overhead transmission power line.

New Technical Trend of Inspection and Test of Transmission Line (가공송전선로 점검 및 진단기술에 대한 해외기술동향)

  • Shin, Tai-Woo;Jang, Suk-Han;Kim, Mu-Soo;Min, Byeong-Wook;Choi, Jin-Sung;Yoon, Gen-Hwa;Gwon, Yeon-Han;Jung, Du-Ok;Bang, Hang-Kwon;Choi, Han-Yeol
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.315-317
    • /
    • 2008
  • Recently, a new construction of transmission line has been through quite hard situation due to demands for a new construction of transmission line have been saturated in south korea and also difficulties of purchasing the routes. In addition, the demands for electricity have been decreased in all of advanced countries of the world due to slowdown of the rate of economic growth. So they are trying to find a way to utilize a existing transmission line by extending the durable period. Therefore this is necessary to apply an applicable technology on domestic markets such as inspection, examination, maintenance of existing transmission lines by introducing advanced countries's example which shall be based on Japan's electric power companies.

  • PDF

A Study on the Surge Analysis considering Surge Arrester and Grounding System in the Combined Distribution System (혼합 배전계통에서 피뢰기적용과 접지시스템 변경을 고려한 서지 해석에 관한 연구)

  • Yun, Chang-Sub;Lee, Jong-Beom;Kim, Beong-Suk
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.204-205
    • /
    • 2006
  • This paper describes the protective ability of lightning arrestor in combined distribution system with power cable. To evaluate the protective ability, change of arrestor and grounding location are considered. On the other hand, arrestor developed by Cooper Power Systems for underground power cable system, is considered to evaluate surge protective ability as in underground system, when arrestor occurs failure has overhead line. The result shows that lightning arrestor in combined distribution system with power cable protect effectively when failure at arrestor in overhead line. On the other hand, arrestor developed by Cooper Power Systems for underground power cable system, is considered to evaluate surge protective ability in underground distribution system, when arrestor of overhead line has failure. The result shows that lightning arrestor installed in underground cable can effectively protected cables from surge when arrestor of overhead line has failure. And also even though grounding locations are decreased, it is revealed that protective ability is nearly similar.

  • PDF

A Study on the Learning GUI for the Load Flow of Power System (전력조류계산을 위한 학습용GUI에 관한 연구)

  • Lee, Hee-Yeong
    • Proceedings of the KIEE Conference
    • /
    • 2004.07e
    • /
    • pp.27-29
    • /
    • 2004
  • This paper presents improved teaching and learning Gill for easily analysis tool of load flow of power system. This GUI includes not only contingency analysis function, but also calculating power loss from transmission line flow. The Gill is friendly for study for power system operation and control because picture provide a better visualizing of relationships between input parameters and effect than a tabula type result. This Gill enables topology and the output data of load flow for line outages to be shown on same picture page. Users can input the system data for power flow on the the picture and can easily see the the result diagram of bus voltage, bus power, line flow. It is also observe the effects of different types of variation of tap, shunt capacitor, loads level, line outages. Proposed Gill has been studied on the Ward-Hale 6-Bus system.

  • PDF