• 제목/요약/키워드: Power inverter

검색결과 3,965건 처리시간 0.03초

3-레벨 부스트 컨버터/TNPC 인버터를 적용한 이중변환 무정전전원장치 개발 (The Development of Double Conversion Uninterruptible Power Supply Using 3-Level Converter/TNPC Inverter)

  • 변용섭;임승범;최규혁;홍순찬;이준영
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2014년도 전력전자학술대회 논문집
    • /
    • pp.83-84
    • /
    • 2014
  • This paper proposes the development of double conversion Uninterruptible Power Supply using 3-Level Converter/TNPC Inverter. The Rectifier of proposed system is operating not only 3-Level boost PFC but also battery discharger. The Inverter is converting DC voltage to AC voltage. And in terms of the efficiency, 3-Level TNPC inverter is improved compared to the origin 2-Level type. To verify the validity of proposed system, experiments were carried out.

  • PDF

VVVF 제어기능을 가진 고주파 인버터 (VVF Control-Based HF Inverter)

  • 노채균;김동희;정원영;이봉섭;남승식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 A
    • /
    • pp.244-246
    • /
    • 1995
  • Recently, developments of high-speed semiconductor Switches as power MOSFET, power IGBT, power SIT have enwidenen the performance of classical inverter configuration, and also allowed the practical application of new inverter configuration, with improved performance and wider operating zones. The paper is study on VVVF type high-frequence inverter using self turn-off devices.

  • PDF

3-레벨 ANPC 인버터의 고장 허용 운전 시 중성점 전압 균형 제어 기법 (Neutral-Point Voltage Balancing Control Scheme for Fault-Tolerant Operation of 3-Level ANPC Inverter)

  • 이재운;김지원;박병건;노의철
    • 전력전자학회논문지
    • /
    • 제24권2호
    • /
    • pp.120-126
    • /
    • 2019
  • This study proposes a neutral voltage balance control scheme for stable fault-tolerant operation of an active neutral point clamped (ANPC) inverter using carrier-based pulse width modulation. The proposed scheme maintains the neutral voltage balance by reconfiguring the switching combination and modulating the reference output voltage in order to solve the degradation of the output characteristic in the fault tolerant operation due to the fault of the power semiconductor switch constituting the ANPC inverter. The feasibility of the proposed control scheme is confirmed by HIL experiment using RT-BOX.

Comparative Analysis of the PWM of an Inverter for an Electric Aircraft Thrust Motor

  • Koo, Bon-soo;Jo, Seong-hyeon;Choi, In-ho
    • 항공우주시스템공학회지
    • /
    • 제15권4호
    • /
    • pp.21-29
    • /
    • 2021
  • As global environmental regulations have been strengthened, the eco-friendly market has grown rapidly. In the field of aircraft, research on electric vertical take-off and landing aircraft that can enter city centers and perform personal air transportation using electric propulsion is ongoing. For aircraft using electric propulsion methods to operate reliably, electric power thrust systems are a key factor. Electric aircraft require a high power density for propulsion systems with strict limits on volume and weight. The efficient control of inverter systems is essential for achieving high power density. Therefore, in this paper, the characteristics of inverters and motors were analyzed through simulations based on the space vector pulse width modulation (PWM) and discontinuous PWM methods for controlling inverter systems.

200MW 석탄화력 순환 유동층 보일러 이차공기송풍기용 H-브릿지 멀티레벨 인버터 현장적용 (Field Application of H-Bridge Multi-level Inverter for Fluidized Bed Combustion Boiler Secondary Air Fan)

  • 김봉석;류호선
    • 전력전자학회논문지
    • /
    • 제12권5호
    • /
    • pp.424-431
    • /
    • 2007
  • 본 논문은 발전소의 이차공기송풍기를 가변 회전수 제어하여 소내 소비 전력을 절감하고 전동기의 직입기동에 의한 스트레스를 줄이기 위하여 실증 적용된 200MW 석탄화력 발전소 순환 유동층 보일러 이차 공기 송풍기 구동용 H-브릿지 멀티레벨 인버터에 관한 것이다. H-브릿지 멀티레벨 인버터는 독립적으로 절연된 직류 부를 갖는 저전압의 단상 인버터(셀 인버터)를 다수 직렬 접속하여 고전압 3상 전압을 출력하는 Cascaded H-브릿지 전압형 인버터이다. 전력연구원은 6.6kV, 1MVA급 인버터 개발, 발전소에 설치, 보일러 점화 전/후 시험 및 계통 병입 후 부하 시험 등을 국내 최초로 성공적으로 완료하였다. 현재 200MW 석탄화력 발전소 이차 공기 송풍기 구동용 인버터는 상업 운전 중에 있다. 본 논문에서는 개발된 H-브릿지 멀티레벨 인버터, 기존 발전 설비와 신규 인버터 시스템의 인터페이스 부분에 해당하는 보일러 DCS(Distributed Control System : 분산 제어 시스템) 로직, 계통 병입 후 시운전 결과에 대하여 상세히 기술하였다.

The Optimized Design of a NPC Three-Level Inverter Forced-Air Cooling System Based on Dynamic Power-loss Calculations of the Maximum Power-Loss Range

  • Xu, Shi-Zhou;He, Feng-You
    • Journal of Power Electronics
    • /
    • 제16권4호
    • /
    • pp.1598-1611
    • /
    • 2016
  • In some special occasions with strict size requirements, such as mine hoists, improving the design accuracy of the forced-air cooling systems of NPC three-level inverters is a key technology for improving the power density and decreasing the volume. First, a fast power-loss calculation method was brought. Its calculation principle introduced in detail, and the computation formulas were deduced. Secondly, the average and dynamic power losses of a 1MW mine hoist acting as the research target were analyzed, and a forced-air cooling system model based on a series of theoretical analyses was designed with the average power loss as a heat source. The simulation analyses proves the accuracy and effectiveness of this cooling system during the unit lifting period. Finally, according to an analysis of the periodic working condition, the maximum power-loss range of a NPC three-level inverter under multi cycle operation was obtained and its dynamic power loss was taken into the optimized cooling system model as a heat source to solve the power device damage caused by instantaneous heat accumulation. The effectiveness and feasibility of the optimization design based on the dynamic power loss calculation of the maximum power-loss range was proved by simulation and experimental results.

Power HILS를 활용한 IEEE 1547-2018 기반 스마트 인버터의 기술개발 및 형식시험 연구 (Application Development and Type Test for Smart Inverter Based on IEEE 1547-2018 Utilizing Power HILS)

  • 신단비;강모세;이현아;홍선리;윤기환;백종복
    • 전기전자학회논문지
    • /
    • 제26권1호
    • /
    • pp.1-9
    • /
    • 2022
  • 전력시스템의 신뢰성을 보장하며 분산전원의 수용성을 높이기 위해 IEEE 1547과 같은 표준을 개정하여 분산전원의 계통 연계기준을 강화하고 있다. 본 논문은 이러한 표준을 준수하는 IEEE 1547-2018 기반의 스마트 인버터 기능의 제어 알고리즘을 제안하고, 스마트 인버터 기술의 검증을 위해 구축한 Power HILS 기반의 테스트 플랫폼을 소개한다. 스마트 인버터 기능 중 Volt-var 제어와 Frequency-watt 제어 알고리즘은 상호운용성 표준을 준수하도록 해당 기능의 curve를 상위로부터 설정할 수 있도록 하며, 각 기능의 Enable 신호 시점을 상위 지령에 따라 제어할 수 있도록 하였다. 표준에 따라 Power HILS 테스트 플랫폼을 통해 Volt-var 제어와 Frequency-watt 제어에 대한 형식시험을 수행하였고, 명시된 표준 형식시험을 전부 만족함을 측정 결과를 통해 검증하였다.

멀티레벨 승압 DC-DC 컨버터와 구성된 독립형 부하를 위한 단상 5레벨 인버터 (Single Phase Five Level Inverter For Off-Grid Applications Constructed with Multilevel Step-Up DC-DC Converter)

  • 이바둘라예브 안바르;박성준
    • 전력전자학회논문지
    • /
    • 제25권4호
    • /
    • pp.319-328
    • /
    • 2020
  • The recent use of distributed power generation systems constructed with DC-DC converters has become extremely popular owing to the rising need for environment friendly energy generation power systems. In this study, a new single-phase five-level inverter for off-grid applications constructed with a multilevel DC-DC step-up converter is proposed to boost a low-level DC voltage (36 V-64 V) to a high-level DC bus (380 V) and invert and connect them with a single-phase 230 V rms AC load. Compared with other traditional multilevel inverters, the proposed five-level inverter has a reduced number of switching devices, can generate high-quality power with lower THD values, and has balanced voltage stress for DC capacitors. Moreover, the proposed topology does not require multiple DC sources. Finally, the performance of the proposed topology is presented through the simulation and experimental results of a 400 W hardware prototype.

도시철도 역사 신재생에너지 활용을 위한 멀티레벨 인버터 개발 (Multilevel Inverter Development to Utilize Renewable Energy in Urban Railway Station)

  • 신승권;김형철;정호성;박종영;현병수
    • 전기학회논문지
    • /
    • 제64권2호
    • /
    • pp.324-330
    • /
    • 2015
  • Energy Saving Methods in existing railway vehicle are considered by active approach such as regenerative energy storage and utilization, eco driving, etc. On the other hands, energy saving measures in railway station are operated by passive method such as reduction of operating time in ventilation system, cooing system and power equipment. To reduce energy and for independence in railway system, it requires an active energy saving measures. It needs to its own power source besides the power source of electric supply company such as renewable energy and regenerative energy and take the advantage of power storage system and stored power are used in optimum time. This paper deal with 3-level NPC inverter and T-type NPC inverter that used in various multi-level topology applicable to the railway system.

Operational Characteristics of a Flux-Lock Type SFCL Integrated with Voltage-Controlled Voltage Source Inverter

  • Lee, Su-Won;Lim, Sung-Hun;Ko, Sung-Hun;Lee, Seong-Ryong
    • Journal of Electrical Engineering and Technology
    • /
    • 제3권4호
    • /
    • pp.546-551
    • /
    • 2008
  • In this paper, a flux-lock type superconducting fault current limiter(SFCL) integrated with a voltage-controlled voltage source inverter(VC-VSI) is proposed. The suggested equipment, which consists of a flux-lock type SFCL and a VCVSI, can perform the fault current limiting operation from the occurrence of a short-circuit. In addition, it can compensate the reactive power that the non-linear load requires and also perform the uninterruptible power supply(UPS) as well as the load voltage stabilization by controlling the amplitude and the phase of the inverter's output voltage. The specification for a test model was determined and its various functions such as the fault current limiting and the power conditioning operations were presented and analyzed via computer simulation. Through the analytical results based on the computer simulation, the validity of the analysis was confirmed and its multi-operation was discussed.