• Title/Summary/Keyword: Power inverter

Search Result 3,963, Processing Time 0.025 seconds

Development of AC Electric Vehicle Propulsion System (Converter/Inverter) using IPM Switching Device (IPM 스위칭 소자를 적용한 AC 전동차 추진제어장치 (Converter/Inverter) 개발)

  • Kim T. Y.;Kno A. S.;Hwang K. C.;Choi J. M.;Kim J. B.
    • Proceedings of the KIPE Conference
    • /
    • 2004.07a
    • /
    • pp.298-302
    • /
    • 2004
  • In this paper, AC electric vehicle propulsion system(Converter/Inverter) using high power semiconductor, UM(Intelligent Power module) is proposed. 2-Parallel operation of two PWM converter is adopted for increasing capacity of system and the VVVF inverter control is used a mixed control algorithm, where the vector control strategy at low speed region and slip-frequency control strategy at high speed region. The proposed propulsion system is verified by experimental results with a 1,350kW converter and 1,100kVA inverter with four 210kW traction motors.

  • PDF

A New Inverter Topology for High Voltage and High Power Applications (고전압 대용량을 위한 새로운 인버터 토폴로지)

  • 김태훈;최세완;박기원;이왕하
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.52 no.2
    • /
    • pp.80-86
    • /
    • 2003
  • In this paper, a new three-phase voltage-source inverter topology for high voltage and high Power applications is proposed to improve the quality of output voltage waveform. A chain converter which is used as an auxiliary circuit generates a ripple voltage and injects it to the conventional 12-step inverter. Thus, the injection of the ripple voltage results in 36-step operation with a link and 60-step operation with two links. The proposed inverter is compared to the conventional multilevel inverter in the viewpoint of ratings of phase- shifting transformers, switching devices and capacitors employed. The proposed scheme is simple to control capacitor voltages compared to the conventional schems and is cost effective for high voltage and high power application over several tens of MVA. The proposed approach is validated through simulation, and the experimental results are provided from a 2KVA laboratory prototype.

A Study on Performance Test of a Photovoltaic System Inverter using Real Time Digital Simulator (RTDS) (RTDS 시험모듈을 이용한 태양광 인버터의 성능시험에 관한 연구)

  • Kim, Eung-Sang;Kim, Seul-Ki;Jeon, Jin-Hong;Ahn, Jong-Bo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.2
    • /
    • pp.325-333
    • /
    • 2007
  • A PV system inverter test module using RTDS was developed and performance test of a commercial PV inverter was carried out. The developed module consists of one RTDS hardware rack, RTDS software models representing PV array and simple distribution system, and two power amplifiers that was specifically designed for generating power corresponding to signals from RTDS. Performance test results verified effectiveness and reliability of the test module. It is expected that the developed test module may help PV inverter manufacturers improve ana test their systems in the developing stage.

Design of New Current Full-Bridge Resonant Inverter for Induction Heating System (유도가열 시스템을 위한 새로운 전류형 풀-브릿지 공진형 인버터 설계)

  • Lee, Sang-Hun;Lim, Sang-Kil;Song, Seung-Gun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.7
    • /
    • pp.59-69
    • /
    • 2012
  • There are two types of inverters that are generally used in induction heating systems: voltage type inverters and high-frequency half-bridge inverters. This paper proposes a new resonant inverter for induction heating systems using the current type full-bridge method. The proposed method can remove capacitors at the input end, and enables unity power factor operation by preventing phase differences of voltage and current. Furthermore, Zero Voltage Switching (ZVS) which is in tune with current type inverter can be adopted and continuous power adjustment is possible through duty ratio changes and frequency modulation in switching operation. Simulations and experiments showed that the proposed current type full-bridge resonant inverter could be used for unity power factor control and ZVS operation in induction heating systems.

PWM Control Techniques for Single-Phase Multilevel Inverter Based Controlled DC Cells

  • Sayed, Mahmoud A.;Ahmed, Mahrous;Elsheikh, Maha G.;Orabi, Mohamed
    • Journal of Power Electronics
    • /
    • v.16 no.2
    • /
    • pp.498-511
    • /
    • 2016
  • This paper presents a single-phase five-level inverter controlled by two novel pulse width modulation (PWM) switching techniques. The proposed PWM techniques are designed based on minimum switching power loss and minimum total harmonic distortion (THD). In a single-phase five-level inverter employing six switches, the first proposed PWM technique requires four switches to operate at switching frequency and two other switches to operate at line frequency. The second proposed PWM technique requires only two switches to operate at switching frequency and the rest of the switches to operate at line frequency. Compared with conventional PWM techniques for single-phase five-level inverters, the proposed PWM techniques offer high efficiency and low harmonic components in the output voltage. The validity of the proposed PWM switching techniques in controlling single-phase five-level inverters to regulate load voltage is verified experimentally using a 100 V, 500 W laboratory prototype controlled by dspace 1103.

DSP-Based Simplified Space-Vector PWM for a Three-Level VSI with Experimental Validation

  • Ramirez, Jose Dario Betanzos;Rivas, Jaime Jose Rodriguez;Peralta-Sanchez, Edgar
    • Journal of Power Electronics
    • /
    • v.12 no.2
    • /
    • pp.285-293
    • /
    • 2012
  • Multilevel inverters have gained attention in high-power applications due to their numerous advantages in comparison with conventional two-level inverters. In this paper a simplified Space-Vector Modulation (SVM) algorithm for a three-level Neutral-Point Clamped (NPC) inverter is implemented on a Freescale$^{(R)}$ DSP56F8037. The algorithm is based on a simplification of the space-vector diagram for a three-level inverter so that it can be used with a two-level inverter. Once the simplification has been achieved, calculation of the dwell times and the switching sequences are carried out in the same way as for the two-level SVM method. Details of the hardware design are included. Experimental results are analyzed to validate the performance of the simplified algorithm.

Optimized Space Vector Pulse-width Modulation Technique for a Five-level Cascaded H-Bridge Inverter

  • Matsa, Amarendra;Ahmed, Irfan;Chaudhari, Madhuri A.
    • Journal of Power Electronics
    • /
    • v.14 no.5
    • /
    • pp.937-945
    • /
    • 2014
  • This paper presents an optimized space vector pulse-width modulation (OSVPWM) technique for a five-level cascaded H-bridge (CHB) inverter. The space vector diagram of the five-level CHB inverter is optimized by resolving it into inner and outer two-level space vector hexagons. Unlike conventional space vector topology, the proposed technique significantly reduces the involved computational time and efforts without compromising the performance of the five-level CHB inverter. A further optimized (FOSVPWM) technique is also presented in this paper, which significantly reduces the complexity and computational efforts. The developed techniques are verified through MATLAB/SIMULINK. Results are compared with sinusoidal pulse-width modulation (SPWM) to prove the validity of the proposed technique. The proposed simulation system is realized by using an XC3S400 field-programmable gate array from Xilinx, Inc. The experiment results are then presented for verification.

Start-up Control of LLC Resonant Inverter for Microwave Oven Application (전자레인지용 LLC 공진형 인버터의 기동 제어)

  • Kang, Kyelyong;Kim, Heung-Geun;Cha, Honnyong
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.22 no.5
    • /
    • pp.463-468
    • /
    • 2017
  • One of the most critical part for magnetron driving in microwave oven is start-up control. For this, switching frequency of resonant inverter should be carefully controlled in order to supply sufficient power to the filament of the magnetron and to prevent rectifier diode from destruction caused by the excessive voltage across them. This paper proposes a novel start-up control strategy for LLC resonant inverter for microwave oven considering the non-oscillation mode time and the magnetron voltage during the start-up process. The validity of the proposed method is verified through the experiment with 1,200W microwave oven using LLC resonant inverter.

High Pulse SCR Inverter for Utility Interactive Renewable Power Generation System (계통연계형 대체에너지 발전시스템을 위한 고펄스 SCR 인버터)

  • Jung, Jae-Hyuck;Kim, Hyun-Jung;Choi, Se-Wan;Kim, Young-Seok;Won, Chung-Yuen
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.85-89
    • /
    • 2001
  • In this paper, a new line-commutated SCR inverter for renewable power generation system is proposed. The proposed inverter system includes a 6-pulse SCR inverter and an auxiliary circuit. By the proper operation of the auxiliary circuit, the pulse number of the inverter system is increased and the output harmonic currents are reduced. Analysis, control and simulation for 24 pulse operation of the proposed scheme is presented and the experimental results will be provided in the final paper.

  • PDF

PQ Control of Micro Grid Inverters with Axial Voltage Regulators

  • Chen, Yang;Zhao, Jinbin;Qu, Keqing;Li, Fen
    • Journal of Power Electronics
    • /
    • v.15 no.6
    • /
    • pp.1601-1608
    • /
    • 2015
  • This paper presents a PQ control strategy for micro grid inverters with axial voltage regulators. The inverter works in the voltage-controlled mode and can help improve the terminal power quality. The inverter has two axial voltage regulators. The 1st regulator involves the output voltage amplitude and output impedance, while the 2nd regulator controls the output frequency. The inverter system is equivalent to a controllable voltage source with a controllable inner output impedance. The basic PQ control for micro grid inverters is easy to accomplish. The output active and reactive powers can be decoupled well by controlling the two axial voltages. The 1st axial voltage regulator controls the reactive power, while the 2nd regulator controls the active power. The paper analyses the axial voltage regulation mechanism, and evaluates the PQ decoupling effect mathematically. The effectiveness of the proposed control strategy is validated by simulation and experimental results.