• Title/Summary/Keyword: Power inverter

Search Result 3,963, Processing Time 0.03 seconds

A Study on Characteristic Analysis of High Frequency Generating Circuit Integrated Chopper-Inverter with High Power-Factor (고역률 초퍼-인버터 일체형 고주파 발생회로의 특성해석에 관한 연구)

  • Won Jae-Sun;Park Jae-Wook;Nam Seung-Sik;Lee Bong-Seob;Seok Jul-Ki;Kim Dong-Hee
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.10
    • /
    • pp.610-617
    • /
    • 2004
  • This paper presents a novel high frequency generating circuit integrated chopper-inverter using ZVS with high power-factor. The proposed topology is integrated half-bridge boost rectifier as power factor corrector(PFC) and half-bridge high frequency resonant inverter into a single-stage. The input stage of the half-bridge boost rectifier works in discontinuous conduction mode(DCM) with constant duty cycle and variable switching frequency. So that a boost converter makes the line current follow naturally the sinusoidal line voltage waveform. Simulation results have demonstrated the feasibility of the proposed high frequency resonant inverter. Characteristics values based on characteristics analysis through circuit analysis is given as basis data in design procedure. Also, experimental results are presented to verify theoretical discussion. This proposed inverter will be able to be practically used as a power supply in various fields as induction heating applications. fluorescent lamp and DC-DC converter etc.

Single-Phase Transformerless Inverter using Passive Bypass Filter (수동 바이패스 필터를 이용한 단상 무변압기형 인버터)

  • Yang, Min-Kwon;Heo, Jun;Lee, Myung-Chul;Kim, Yu-Jin;Choi, Woo-Young
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.23 no.2
    • /
    • pp.129-138
    • /
    • 2018
  • Previous single-phase transformerless inverters used active bypass switching circuits that need auxiliary power switches to minimize ground leakage current. However, switching and gate driving losses are increased due to the use of additional power switches. To cope with this drawback, this work proposes a transformerless inverter using a passive bypass filter without any auxiliary power switch. The operation and control of the proposed inverter are described. The ground leakage current characteristics are analyzed for the proposed inverter with the passive bypass filter. The experimental results of the proposed inverter for a 1.0kW prototype system are presented.

Induction Heating PWM High Frequency Inverter using New Active Auxiliary Resonant Snubber

  • Mun, Sang-Pil;Kim, Chil-Ryong;Lee, Jong-Kurl;Kim, Hong-Sin;Jung, Sang-Hwa;Kwon, Soon-Kurl
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.3
    • /
    • pp.40-51
    • /
    • 2008
  • This research presents a new active auxiliary resonant snubber with for induction heating PWM high frequency inverter solving the problem of induction heating PWM high frequency inverter circuit which is using widely in the practical application of an induction heating apparatus, the soft switching operation and power control are impossible when the lowest power supply in the active auxiliary resonant snubber with for induction heating PWM high frequency inverter. The inverter circuit which is attempted by the on-off operation of a switch has the effect of reducing the power loss due to soft switching and high frequency switching. This confirms that power regulation is possible on a continuous basis from 0.25[kW] to 2.84[kW] where the duty factor(D) changes from 0.08 to 0.3 under zero current switching which operates by an asymmetrical pulse width modulating control. The power conversion efficiency is 95[%]. Due to these results, the active auxiliary resonant snubber for an induction heating PWM high frequency inverter is considered effective as a source of induction heating.

Induction Heating ZCS PWM SEPP High Frequency Inverter (유도가열용 ZCS PWM SEPP 고주파 인버터)

  • Mun, Sang-Pil;Gwon, Sun-Geol;Lee, Jong-Geol;Ju, Seok-Min;Gang, Sin-Chul
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.10a
    • /
    • pp.241-243
    • /
    • 2008
  • This research presented the new zero-current switching pulse width modulation SEPP(Single Ended Push-Full)high frequency inverter for solving the problem of the zero-current SEPP high frequency inverter circuit which is using widely in the practical application of an induction heating apparatus, the soft switching operation and power control are impossible when the lowest power supply in the zero-current switching pulse width modulation SEPP high frequency inverter. The inverter circuit which is attempted by on-off operation of a switch has the reduction effect of the power loss due to a soft switching and a high frequency switching. And it confirmed that the power regulation is possible continuously from 0.25[kW] until 2.84[kW] in the case the duty rate(D) changes from 0.08 to 0.3 under zero-current switching operating by a dissymmetry pulse width modulating control and the power conversion efficiency comes true the efficiency of 95[%]. Due to the result above, the ZCS PWM SEPP high frequency inverter will be effective as sources of an induction heating apparatus.

  • PDF

Three Phase Voltage Source Soft Switching Inverter with High Frequency Pulse Current Transformers

  • Inaba, Claudio Y.;Hiraki, Eiji;Nakaoka, Mutsuo
    • Journal of Power Electronics
    • /
    • v.2 no.4
    • /
    • pp.288-296
    • /
    • 2002
  • In this paper, a high frequency transformer - assisted auxiliary active resonant commutated snubber (HFTA-ARCS) for voltage source soft switching pulse width modulated power conversion circuits is presented. A three phase voltage source type soft switching inverter incorporating HFTA-ARCS circuits in its three bridge legs can reduce current rating of auxiliary active power switches and has sensorless simplified control scheme which any specified boost current management is not required for soft switching. Its operation principle and digital control scheme are described and a practical design method of circuit parameters on this HFTA-ARCS circuit is also introduced on the basis of computer simulation. Moreover, this space voltage vector modulated soft switching inverter system with DSP-based digital control scheme Is discussed and its effectiveness is proved on the basis of performance evaluations. The operating performances of this inverter system are also compared with those of conventional three-phase hard switching inverter under practical conditions of specified parameters.

Implementation of Cuckoo Search Optimized Firing Scheme in 5-Level Cascaded H-Bridge Multilevel Inverter for Power Quality Improvement

  • Singla, Deepshikha;Sharma, P.R.
    • Journal of Power Electronics
    • /
    • v.19 no.6
    • /
    • pp.1458-1466
    • /
    • 2019
  • Multilevel inverters have appeared as a successful and utilitarian solution in many power applications. The prime objective of an inverter is to keep the fundamental component of the output voltage of a multilevel inverter at a preferred value. Equally important is the need to keep the harmonic components in the output voltage within stated harmonic limits. Therefore, the basis of this research is to develop a harmonic minimization function that optimizes the switching angles of cascaded H-bridge multilevel inverter. Due to benefits of the Cuckoo Search (CS) algorithm, it is applied to determine the switching angles, which are further used to generate the switching pattern for firing the H-bridges of multilevel inverter. Simulation results are compared with SPWM based firing scheme. The switching frequency for SPWM firing scheme is taken as 200 Hz since the switching losses are increased when switching frequency is high. To validate the ability of Cuckoo Search optimized firing scheme in minimization of harmonics, experimental results obtained from hardware prototype of Five Level Cascaded H-Bridge Multilevel Inverter equipped with a FPGA controller are presented to verify the simulation results.

An Output Voltage Balance Control of Grid Connected Inverter by Phase Current Control at Critical Load Unbalanced Condition (계통연계 인버터의 주요 부하 불평형 시 상전류 제어를 통한 부하 상전압 평형 제어)

  • Tae-Hyeon Park;Hag-Wone Kim;Kwan-Yuhl Cho;Joon-Ki Min;Won-Il Choi
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.28 no.1
    • /
    • pp.22-29
    • /
    • 2023
  • A grid-connected inverter can be used in grid-connected or stand-alone modes. Generally, a grid-connected inverter operates in a grid-connected mode, but the inverter operates in stand-alone mode if grid faults occur. In the stand-alone mode, the grid-connected inverter must supply electric power to a critical load that needs to receive stable power even though grid faults occur. Generally, three-phase loads are used as critical loads, but a single phase is configured in some cases. In these conditions, the critical load is required to unbalance the load power consumption, which makes the three-phase load voltage unbalancd. This unbalanced voltage problem can cause fatal problems to the three-phase critical loads, and thus must be addressed. Hence, this paper proposes an algorithm to solve this unbalanced voltage problem by the individual phase current control. The proposed method is verified using Psim simulation and experiments.

A Study on the New Maximum Power Point Tracking and Current Ripple Reduction of Solar Cell for the Grid-connected PV Inverter (계통연계형 태양광 인버터의 새로운 최대 전력점 추종과 태양전지의 전류리플 감소에 관한 연구)

  • Hwang, Uiseon;Kang, Moonsung;Yang, Oh
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.5
    • /
    • pp.1187-1195
    • /
    • 2013
  • Photovoltaic inverters should always track the maximum power of solar cell arrays in operation. Also, they should be irrespective of the maximum power point voltage of a wide range of solar cells in tracking the maximum power point. If the current ripple of solar cells occurs, the function of maximum power point tracking drops, and normal tracking is difficult when solar radiation or the maximum power point changes. To solve this problem, this paper proposed a new maximum power point tracking algorithm with high efficiency and an algorithm to reduce the current ripple of solar cells. According to the results from the test on 4KW grid-connected PV inverter, the efficiency of maximum power point tracking and inverter output and the total harmonic distortion of inverter output current showed 99.97%, 97.5% and 1.05% respectively. So, the inverter showed excellent performance, and made possible stable maximum power point tracking operation when the solar radiation rapidly changed from 100% to 10% and from 10% to 100% for 0.5 seconds.

Automatic frequency Control Current-Source Inverter for Forging Application

  • Chudjuarjeen, Saichol;Koompai, Chayant;Monyakul, Veerapol
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.238-242
    • /
    • 2004
  • The paper describes an automatic frequency control current-fed inverter for forging applications. The IGBT in series with diodes as its switching devices in the inverter circuit which is of full-bridge type. The operating frequency is automatically tracked to maintain a small constant leading phase angle when load parameters change. The load voltage is controlled to protect the switches. The output power can be adjusted by varying the input current from phase controlled rectifiers which is a part of current source. The system has been operated at 15-17 kHz. The output power transferred to the load is 1,595 watts. It can heat the steel work pieces with 15 mm diameter and 120 mm long from room temperature to approximately 1100 $^{\circ}C$ within 20 seconds with 0.97 leading power factor on the input side.

  • PDF

A Study on about Implementation to Induction Cooker that load Turbo Inverter algorithm

  • Lee Min-Ki;Koh Kang-Hoon;Kwon Soon-Kurl;Lee Hyun-Woo;nakaoka M.
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.136-139
    • /
    • 2001
  • The voltage resonating inverter has a defect in the switching element that works at 5 or 6 times higher than input voltage. Especially, it is very difficult to choose very high switching device for the 220[V]commercial voltage. In this paper, it is proposed the optimum method to realize the turbo 2000[W] power for induction cooker that is employed the 900[V] IGBT with decreasing operating voltage of the switching component by making the 220[V], 1500[W] inverter through the clamp mode voltage resonating inverter.

  • PDF