Study on the Variation Characteristic of the Photo-Volatic Power Generation due to Regional Meteorological Elements (국지 기상 요소에 의한 태양광 발전량 변동특성에 관한 연구)

  • Lee, Soon-Hwan;Kim, Hae-Dong;Cho, Chang-Bum
    • Journal of Environmental Science International
    • /
    • v.23 no.11
    • /
    • pp.1943-1951
    • /
    • 2014
  • In order to clarify the characteristics of Photo-Volatic(PV) power generation over the Korean peninsula with complex terrain, special meteorological observation campaign was carried out for one year from 25 May 2011. Analysis is based on the comparison between observed meteorological elements and PV values generated at rated capacity 200 kW power plants. Solar radiation observed at $15^{\circ}$ inclined surface is 11 % larger than that observed at horizontal surface due to low elevation angel of the sun during winter season. The PV power generation tend to be more similar the variation of inclined surface irradiance than horizontal surface irradiance. Increasing air temperature often induce disturbance of the PV power generation. However, the higher the air temperature in winter season, the higher PV power generation because the PV module may be more activated at higher air temperature. PV generating efficiency tends to be conversed the value of 15%.

Design of a Microcontroller Based Electronic Load Controller for a Self Excited Induction Generator Supplying Single-Phase Loads

  • Gao, Sarsing;Murthy, S. S.;Bhuvaneswari, G.;Gayathri, M. Sree Lalitha
    • Journal of Power Electronics
    • /
    • v.10 no.4
    • /
    • pp.444-449
    • /
    • 2010
  • The generation of electric power using self excited induction generation (SEIG) is a viable option in remote and rural areas where grid electricity is not available. The generated voltage and frequency of these machines, however, varies with varying loads. This characteristic can be resolved either by adjusting the values of the excitation capacitance or by controlling the prime mover speed. Further, in a single-point constant power application, where the machines deliver a fixed amount of power, the electronic load controller (ELC) can be used to switch-in or switch-out a dump load whenever the consumer load decreases or increases respectively. This paper presents a detailed analysis and the design of a microcontroller based SEIG -ELC system intended for stand-alone pico hydro power generation. The simulated performance of the controller is supplemented by experimental results.

Neuro PID Control for Ultra-Compact Binary Power Generation Plant (초소형 바이너리 발전 플랜트를 위한 Neuro PID 제어)

  • Han, Kun-Young
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.25 no.11
    • /
    • pp.1495-1504
    • /
    • 2021
  • An ultra-compact binary power generation plant converts thermal energy into electric power using temperature difference between heat source and cooling source. In the actual power generation environment, the characteristic value of the plant changes due to any negative effects such as environmental condition or corrosion of related equipment. If the characteristic value of the plant changes, it may lead to unstable output of the turbine in a conventional PID control system with fixed PID parameters. A Neuro PID control system based on Neural Network adaptively to adjust the PID parameters according to the change in the characteristic value of the plant is proposed in this paper. Discrete-time transfer function models to represent the dynamic characteristics near the operating point of the investigated plant are deduced, and a design strategy of the proposed control system is described. The proposed Neuro PID control system is compared with the conventional PID control system, and its effectiveness is demonstrated through the simulation results.

Optimal Operation Model of Heat Trade based District Heating and Cooling System Considering Start-up Characteristic of Combined Cycle Generation (가스터빈 복합발전의 기동특성을 고려한 열거래 기반 지역 냉난방 시스템의 최적 운영 모델)

  • Kim, Jong-Woo;Lee, Ji-Hye;Kim, Hak-Man
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.11
    • /
    • pp.1610-1616
    • /
    • 2013
  • Recently, district heating and cooling (DHC) systems based on combined cycle generation (CCG) providers are increasing in Korea. Since characteristics of combined heat and power (CHP) generators and heat demands of providers, heat trading between DHC providers based on the economic viewpoint is required; the heat trading has been doing. In this paper, a mathematical model for optimal operation based on heat trading between DHC providers is proposed. Especially, start-up characteristic of CCG is included. The operation model is established by mixed integer linear programming (MILP).

A Study on Design of the Compensation System for Wind Energy Generation by Power Storage Apparatus (동력저장장치를 이용한 풍력발전 보상 시스템 설계에 관한 연구)

  • 윤석암;차인수;백행래
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.6 no.1
    • /
    • pp.43-48
    • /
    • 2001
  • In conventional wind generation systems, since the blade rotates at low speed when the velocity of wind decreases their operations are possible only under limited conditions. Therefore they are in trouble of self-generation without the help of auxiliary generation devices outside. In addition, most of them have very low usage efficiency because of the characteristic changes of wind. For the solution of these problems and for enough generation regardless of districts and geographical features the rotation energy stored in a spring drives a compact generator and then electric power is stored at battery and supplied to the load continuously according to the lack of wind force. In this paper, the fabricated system consisting of a wind generator and power storage apparatus was introduced and its operation characteristics were analyzed.

  • PDF

Use of the Moving Average of the Current Weather Data for the Solar Power Generation Amount Prediction (현재 기상 정보의 이동 평균을 사용한 태양광 발전량 예측)

  • Lee, Hyunjin
    • Journal of Korea Multimedia Society
    • /
    • v.19 no.8
    • /
    • pp.1530-1537
    • /
    • 2016
  • Recently, solar power generation shows the significant growth in the renewable energy field. Using the short-term prediction, it is possible to control the electric power demand and the power generation plan of the auxiliary device. However, a short-term prediction can be used when you know the weather forecast. If it is not possible to use the weather forecast information because of disconnection of network at the island and the mountains or for security reasons, the accuracy of prediction is not good. Therefore, in this paper, we proposed a system capable of short-term prediction of solar power generation amount by using only the weather information that has been collected by oneself. We used temperature, humidity and insolation as weather information. We have applied a moving average to each information because they had a characteristic of time series. It was composed of min, max and average of each information, differences of mutual information and gradient of it. An artificial neural network, SVM and RBF Network model was used for the prediction algorithm and they were combined by Ensemble method. The results of this suggest that using a moving average during pre-processing and ensemble prediction models will maximize prediction accuracy.

A Study on Ozone Generation Characteristic using Ba-Ti-Si Ceramic Tube (Ba-Ti-Si 세라믹 방전관의 오존 발생 특성 연구)

  • 이동훈;박홍재;박재윤
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.7
    • /
    • pp.634-640
    • /
    • 2003
  • This paper is to be researched into ozone generation character of Bi-Ti-Si type high dielectric yield ceramic catalyst discharge tube. And conditions of basic experiment are the outside diameter of discharge tube : 52 mm, the length of discharge tube : 350 mm, the frequence : 900 Hz, the temperature of cooling water : 25 $^{\circ}C$, quantity of flow : 5, 10, 20 l/min, pressure : 1.2, 1.4, 1.6 atm, and distance of discharge gap : 0.4, 0.6, 0.8 mm. Ozone generation characteristics were measured to consumption power. At quantity of flow : 20 l/min, discharge gap : 0.6 mm, pressure : 1.6, and consumption power : 150 W, Maximum ozone generation efficiency of 175 g/kWh was obtained. Maximum ozone generation efficiency was measured below the flow quantity of 20 l/min at below pressure of 1.6 atm. However, Maximum ozone generation efficiency was measured over the flow quantity of 20 l/min at over pressure of 1.6 atm.

EMTDC Model Development for Control & Protection Analysis of Co-Generation System based on On-site Characteristic Tests (현장 측정에 근거한 열병합 발전 시스템의 제어, 보호 해석용 EMTDC 모델 수립)

  • Kim, Hak-Man;Shin, Myong-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.5
    • /
    • pp.85-91
    • /
    • 2006
  • Co-generation systems have been spreading rapidly over the past 10 years in Korea and most of these systems are interconnected with electric power systems. However, better control and protection models are still needed for analysis of these systems to ensure stable operation with the grid. This paper proposes improved EMTDC models for control fad protection analysis of grid-connected co-generation systems. Through on-site characteristic testing, the models were developed and the model parameters were determined. The models were applied to a field co-generation system, and analysis of control and protection was performed showing a good match to the simulation results.

Study on Generation Volume of Floating Solar Power Using Historical Insolation Data (과거 일사량 자료를 활용한 수상태양광 발전량 예측 연구)

  • Na, Hyeji;Kim, Kyeongseok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.43 no.2
    • /
    • pp.249-258
    • /
    • 2023
  • Solar power has the largest proportion of power generation and facility capacity among renewable energy in South Korea. Floating solar power plant is a new way to resolve weakness of land solar power plant. This study analyzes the power generation of the 18.7 MW floating solar power project located in Saemangeum, Gunsan-si. Since the solar power generation has a characteristic that is greatly affected by the climate, various methods have been applied to predict solar power generation. In general, variables necessary for predicting power generation are solar insolation on inclined surfaces, solar generation efficiency, and panel installation area. This study analyzed solar power generation using the monthly solar insolation data from the KMA (Korea Meteorological Administration) over the past 10 years. Monte Carlo simulation (MCS) was applied to predict the solar power generation with the variables including solar panel efficiency and insolation. In the case of Saemangeum solar power project, the most solar power generation was in May, the least was in December, the average solar power generation simulated on MCS is 2.1 GWh per month, the minimum monthly power generation is 0.3 GWh, and the maximum is 5.0 GWh.

Development of Intelligent Landscape Lighting Power Control and Monitoring System with Solar Cell Generator Equipment (태양광발전설비와 연계한 지능형 경관조명 전력제어 및 모니터링 시스템의 개발)

  • Kim, Dong-Wan;Park, Sung-Won;Kim, Hyung-Su
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.60 no.2
    • /
    • pp.99-104
    • /
    • 2011
  • In this paper, the intelligent landscape lighting power control and monitoring system with solar sell generator equipment is proposed. The first, the intelligent landscape lighting power controller is designed using the fuzzy logic control method. And the fuzzy logic controller is used to save power consumption for various reference intensity of the illumination. The second, the GUI monitoring system is presented. It has control and display faculty. And the practical experiment device is used to evaluate the performance criteria of the proposed intelligent landscape lighting power control system with the solar cell power generation equipment. From the experiment results, we present the property of proposed fuzzy controller such as steady state error, the tracking and power consumption characteristic for the reference intensity of illumination. And also we show the superiority of power control as well as the characteristic of GUI monitoring system in the proposed system.