• Title/Summary/Keyword: Power distribution system

Search Result 3,026, Processing Time 0.034 seconds

ANALYSIS OF THE TRANSPORTATION LOGISTICS FOR SPENT NUCLEAR FUEL IN KOREA

  • Lee, Hyo-Jik;Ko, Won-Il;Seo, Ki-Seok
    • Nuclear Engineering and Technology
    • /
    • v.42 no.5
    • /
    • pp.582-589
    • /
    • 2010
  • As a part of the back-end fuel cycle, transportation of spent nuclear fuel (SNF) from nuclear power plants (NPPs) to a fuel storage facility is very important in establishing a nuclear fuel cycle. In Korea, the accumulated amount of SNF in the NPP pools is troublesome since the temporary storage facilities at these NPP pools are expected to be full of SNF within ten years. Therefore, Korea cannot help but plan for the construction of an interim storage facility to solve this problem in the near future. Especially, a decision on several factors, such as where the interim storage facility should be located, how many casks a transport ship can carry at a time and how many casks are initially required, affect the configuration of the transportation system. In order to analyze the various possible candidate scenarios, we assumed four cases for the interim storage facility location, three cases for the load capacity that a transport ship can carry and two cases for the total amount of casks used for transportation. First, this study considered the currently accumulated amount of SNF in Korea, and the amount of SNF generated from NPPs until all NPPs are shut down. Then, how much SNF per year must be transported from the NPPs to an interim storage facility was calculated during an assumed transportation period. Second, 24 candidate transportation scenarios were constructed by a combination of the decision factors. To construct viable yearly transportation schedules for the selected 24 scenarios, we created a spreadsheet program named TranScenario, which was developed by using MS EXCEL. TranScenario can help schedulers input shipping routes and allocate transportation casks. Also, TranScenario provides information on the cask distribution in the NPPs and in the interim storage facility automatically, by displaying it in real time according to the shipping routes, cask types and cask numbers that the user generates. Once a yearly transportation schedule is established, TranScenario provides some statistical information, such as the voyage time, the availability of the interim storage facility, the number of transported casks sent from the NPPs, and the number of transported casks received at the interim storage facility. By using this information, users can verify and validate a yearly transportation schedule. In this way, the 24 candidate scenarios could be constructed easily. Finally, these 24 scenarios were compared in terms of their operation cost.

Evaluation of MR-SENSE Reconstruction by Filtering Effect and Spatial Resolution of the Sensitivity Map for the Simulation-Based Linear Coil Array (선형적 위상배열 코일구조의 시뮬레이션을 통한 민감도지도의 공간 해상도 및 필터링 변화에 따른 MR-SENSE 영상재구성 평가)

  • Lee, D.H.;Hong, C.P.;Han, B.S.;Kim, H.J.;Suh, J.J.;Kim, S.H.;Lee, C.H.;Lee, M.W.
    • Journal of Biomedical Engineering Research
    • /
    • v.32 no.3
    • /
    • pp.245-250
    • /
    • 2011
  • Parallel imaging technique can provide several advantages for a multitude of MRI applications. Especially, in SENSE technique, sensitivity maps were always required in order to determine the reconstruction matrix, therefore, a number of difference approaches using sensitivity information from coils have been demonstrated to improve of image quality. Moreover, many filtering methods were proposed such as adaptive matched filter and nonlinear diffusion technique to optimize the suppression of background noise and to improve of image quality. In this study, we performed SENSE reconstruction using computer simulations to confirm the most suitable method for the feasibility of filtering effect and according to changing order of polynomial fit that were applied on variation of spatial resolution of sensitivity map. The image was obtained at 0.32T(Magfinder II, Genpia, Korea) MRI system using spin-echo pulse sequence(TR/TE = 500/20 ms, FOV = 300 mm, matrix = $128{\times}128$, thickness = 8 mm). For the simulation, obtained image was multiplied with four linear-array coil sensitivities which were formed of 2D-gaussian distribution and the image was complex white gaussian noise was added. Image processing was separated to apply two methods which were polynomial fitting and filtering according to spatial resolution of sensitivity map and each coil image was subsampled corresponding to reduction factor(r-factor) of 2 and 4. The results were compared to mean value of geomety factor(g-factor) and artifact power(AP) according to r-factor 2 and 4. Our results were represented while changing of spatial resolution of sensitivity map and r-factor, polynomial fit methods were represented the better results compared with general filtering methods. Although our result had limitation of computer simulation study instead of applying to experiment and coil geometric array such as linear, our method may be useful for determination of optimal sensitivity map in a linear coil array.

A Study of the Attitude and Experience for Sexual Harassment in Adolescence (남녀 고등학생의 성희롱에 대한 태도 및 경험에 관한 조사연구)

  • Chung, Eui-Nam;Park, Shin-Ae
    • Research in Community and Public Health Nursing
    • /
    • v.11 no.2
    • /
    • pp.538-555
    • /
    • 2000
  • The purpose of this study, in which 573 students from 2 high schools in Kang Nung city participated was to identify the attitude and experience of sexual harassment. This information will provide useful data, and promote a more systematic sexual harassment education program. The subjects of this study were 278 male students and 295 female students. The data was collected from September 25 to October 6. 2000. The data was analyzed using the statistical Computer package. SPSS to manipulate the data along with frequency, percentage, and mean t-test. The results from this study were summarized as follows. 1. The results from this comparison between two groups were significant in their attitude on sexual harassment(t=-2.26. p=0.024). Female students had higher scores than male students. 2. As a cause of sexual harassment. 'A man's misjudgement regarding a women as sexual objects(n=130: 22.7%)'. 'Patriarchal system of unequal distribution of power and status between the sexes(n=105: 18.3%)'. 'The effect of sexual stimulatives. (pornography. pornovideo. TV program ect.)(n=89: 15.5%)'. 3. As a countermeasure for prevention, 'Punishment, law and regulation of the sexual harasser(n = 151; 26.4%)', 'A preventive education of sexual harassment in adolescence (n = 125: 21.8%)'. 'Reformation of gender inequality and sex discrimination in the socio-structure(n=76; 13.3%)'. 4. Out of 573 students who participated in this study, 209(36.5%) students reported experiencing an incident of sexual harassment. For 278 males who participated in this study, 88(31.7%) had experienced an incident of sexual harassment. For the 295 females who participated in this study, 121(41.0%) had experienced an incident of sexual harassment. The type of sexual harassment is reported physical sexual harassment(n = 248: 40.5%), verbal sexual harassment(n = 226; 36.7%), and visual sexual harassment(n=139: 22.6%). 5. Their age in which they had experienced harassment was usually 'after 16 years of age(n=122: 58.4%)'. The age of harassers were mostly teenagers(n=112; 53.6%). The relationship to the with sexual harasser was a stranger (n=85; 40.7%), or a friend(n=78: 37.3%). After the incident of sexual harassment occurred, some students informed friends (n=114: 54.5%), 63(30.1%) told no one. Male students' feelings after the experienced harassment ranged from: 'be interesting', 'be pleasant'. Female students' feelings after the experienced harassment ranged from; 'be surprised', 'get a shock', 'fear', 'shame'.

  • PDF

Feasibility Analysis on Replacing LED Lighting with Incandescent Bulbs in Public Institution (백열 전구의 LED 조명 교체에 대한 타당성 분석 - 공공기관을 중심으로 -)

  • Park, Youn Mi;Lee, Myung Koon
    • Journal of Climate Change Research
    • /
    • v.1 no.3
    • /
    • pp.205-210
    • /
    • 2010
  • LED light has various advantages such as an energy saving effect of over 80% compared to existing lighting and environmentally friendly characteristics; however, there has been no affordable market for LED lighting because of its expensive price. This study discussed the validity of the expansion of distribution of LED lighting through an assessment of economic efficiency concerning LED lightening in order to analyze its efficiency in terms of energy savings and maintenance and repair, which will be generated as a result of the change from existing incandescent bulbs to LED lighting in the public sector. As to the target of analysis, the paper reviewed the validity of change to LED lighting as a result of the elimination of existing incandescent bulbs, by referring to 'the current incandescent bulb use and elimination performance' published by the Ministry of Knowledge Economy based on the "Elimination management system" executed by Korea Energy Management Corporation. The paper considered expenses for change, annual power savings amount and electric charges savings amount, repair and maintenance cost, $CO_2$ reduction volume, and the profit from the sale of CER (certified emission reduction). As a result of analyzing economic efficiency, when the discount rate during the change of existing incandescent bulb lighting to LED lighting is 3.26%, the profit was 8,648,400,000 won. Accordingly, NPV was analyzed to have a 'positive (+)' value, which means that this change is profitable.

Calculation of optimal design flood using cost-benefit analysis with uncertainty (불확실성이 고려된 비용-편익분석 기법을 도입한 최적설계홍수량 산정)

  • Kim, Sang Ug;Choi, Kwang Bae
    • Journal of Korea Water Resources Association
    • /
    • v.55 no.6
    • /
    • pp.405-419
    • /
    • 2022
  • Flood frequency analysis commonly used to design the hydraulic structures to minimize flood damage includes uncertainty. Therefore, the most appropriate design flood within a uncertainty should be selected in the final stage of a hydraulic structure, but related studies were rarely carried out. The total expected cost function introduced into the flood frequency analysis is a new approach for determining the optimal design flood. This procedure has been used as UNCODE (UNcertainty COmpliant DEsign), but the application has not yet been introduced in South Korea. This study introduced the mathematical procedure of UNCODE and calculated the optimal design flood using the annual maximum inflow of hydroelectric dams located in the Bukhan River system and results were compared with that of the existing flood frequency. The parameter uncertainty was considered in the total expected cost function using the Gumbel and the GEV distribution, and the Metropolis-Hastings algorithm was used to sample the parameters. In this study, cost function and damage function were assumed to be a first-order linear function. It was found that the medians of the optimal design flood for 4 Hydroelectric dams, 2 probability distributions, and 2 return periods were calculated to be somewhat larger than the design flood by the existing flood frequency analysis. In the future, it is needed to develop the practical approximated procedure to UNCODE.

A Design of Ultra Compact S-Band PCM/FM Telemetry Transmitter (초소형 S-대역 PCM/FM 텔레메트리 송신기 설계 및 제작)

  • Jun, Ji-ho;Park, Ju-eun;Kim, Seong-min;Min, Se-hong;Lee, Jong-hyuk;Kim, Bok-ki
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.50 no.11
    • /
    • pp.801-807
    • /
    • 2022
  • In this paper, we propose an ultra compact S-Band PCM/FM telemetry transmitter. The equipment is compact, so it can be applied to a limited space and capable of stable data transmission was designed and manufactured even with specifications set differently for each operating environment and system. RF direct conversion structure is used for the miniaturization of equipment, an RF transmission board, Power distribution board, and a signal processing board were implemented on a single PCB, so that the function of the transmitter could be performed with a minimum device. According to the target specification, variable output of 1~10W and variable data rate of 390kbps~12.5Mbps is possible in S-Band(2,200~2,400MHz) without degradation of performance. To verify the performance of the equipment, the RF performance test and BER measurement test were performed after the equipment was manufactured. It was confirmed that the OBW, null-to-null bandwidth, 1st IMD, Spurious emission, Phase noise specification of the PCM/FM modulated signal which is presented by the IRIG standard were satisfied, and we can confirm the data received using the transmitter inspection equipment were transmitted normally without distortion.

Growth Behavior of Heteroepitaxial β-Ga2O3 Thin Films According to the Sapphire Substrate Position in the Hot Zone of the Mist Chemical Vapor Deposition System (미스트화학기상증착 시스템의 Hot Zone 내 사파이어 기판 위치에 따른 β-Ga2O3 이종 박막 성장 거동 연구)

  • Kyoung-Ho Kim;Heesoo Lee;Yun-Ji Shin;Seong-Min Jeong;Si-Young Bae
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.36 no.5
    • /
    • pp.500-504
    • /
    • 2023
  • In this study, the heteroepitaxial thin film growth of β-Ga2O3 was studied according to the position of the susceptor in mist-CVD. The position of the susceptor and substrate was moved step by step from the center of the hot zone to the inlet of mist in the range of 0~50 mm. It was confirmed that the average thickness increased to 292 nm (D1), 521 nm (D2), and 580 nm (D3) as the position of the susceptor moved away from the center of the hot zone region. The thickness of the lower region of the substrate is increased compared to the upper region. The surface roughness of the lower region of the substrate also increased because the nucleation density increased due to the increase in the lifetime of the mist droplets and the increased mist density. Therefore, thin film growth of β-Ga2O3 in mist-CVD is performed by appropriately adjusting the position of the susceptor (or substrate) in consideration of the mist velocity, evaporation amount, and temperature difference with the substrate, thereby determining the crystallinity of the thin film, the thickness distribution, and the thickness of the thin film. Therefore, these results can provide insights for optimizing the mist-CVD process and producing high-quality β-Ga2O3 thin films for various optical and electronic applications.

A Study on the Comparison between an Optical Fiber and a Thermal Sensor Cable for Temperature Monitoring (온도 모니터링을 위한 광섬유 센서와 온도센서 배열 케이블의 비교 연구)

  • Kim, Jung-Yul;Song, Yoon-Ho;Kim, Yoo-Sung
    • Journal of the Korean Geotechnical Society
    • /
    • v.23 no.4
    • /
    • pp.15-24
    • /
    • 2007
  • Two kinds of temperature monitoring technology have been introduced in this study, which can measure coincidently temperatures at many points along a single length of cable. One is to use a thermal sensor cable comprizing of addressable thermal sensors. The other is to use an optic fiber sensor with Distributed Temperature Sensing (DTS) system. The differences between two technologies can be summarized as follows: A thermal sensor cable has a concept of "point sensing" that can measure temperature only at a predefined position. The accuracy and resolution of temperature measurement are up to the capability of the individual thermal sensor. On the other hand, an optic fiber sensor has a concept of "distributed sensing" because temperature is measured practically at all points along the fiber optic cable by analysing the intensity of Raman back-scattering when a laser pulse travels along the fiber. Thus, the temperature resolution depends on the measuring distance, measuring time and spatial resolution. The purpose of this study is to investigate the applicability of two different temperature monitoring techniques in technical and economical sense. To this end, diverse experiments with two techniques were performed and two techniques are applied under the same condition. Considering the results, the thermal sensor cable will be well applicable to the assessment of groundwater flow, geothermal distribution and grouting efficiency within about loom distance, and the optic fiber sensor will be suitable for long distance such as pipe line inspection, tunnel fire detection and power line monitoring etc.

Development procedures of franchise Industries in Current state of manpower and research on its utilization (프랜차이즈 산업 발전과정에서 인력현황 및 활용에 대한 연구)

  • Lee, Dong il;Park, Shinja
    • The Korean Journal of Franchise Management
    • /
    • v.1 no.1
    • /
    • pp.43-63
    • /
    • 2010
  • Currently, franchise industries are constantly rising in the domestically and it is possible to predict that franchise industries will rapidly develop internationally. Local Franchisee markets are increasing quickly and in year 2010 their income will exceed 114 trillion won. Annually, new franchise system is being born; however, there are only few industries that success in the market. When circulation market was opened for foreign franchise industries, their numbers of franchisee were rapidly increasing; however, domestic franchise industries are not securing new franchise and strengthening current franchise 's man power moreover these implements are being discarded. Therefore, in this research shows that development procedures of franchise division and utilization of personnel, and subsequent to this research indicates that changes of scales and income of cooperate growth will determine numbers of manpower on franchise industry. N ow days, when we are looking at personnel in franchise industries, they need more personnel in distribution, finance, and accounting department, so this phenomenon formalize life cycle of organization and its stages. When we are considering life cycle of organization, needs of human resource on future is important.

A Brief Review of Backgrounds behind "Multi-Purpose Performance Halls" in South Korea (우리나라 다목적 공연장의 탄생배경에 관한 소고)

  • Kim, Kyoung-A
    • (The) Research of the performance art and culture
    • /
    • no.41
    • /
    • pp.5-38
    • /
    • 2020
  • The current state of performance halls in South Korea is closely related to the performance art and culture of the nation as the culture of putting on and enjoying a performance is deeply rooted in public culture and arts halls representing each area at the local government level. Today, public culture and arts halls have multiple management purposes, and the subjects of their management are in the public domain including the central and local governments or investment and donation foundations in overwhelming cases. Public culture and arts halls thus have close correlations with the institutional aspect of cultural policies as the objects of culture and art policies at the central and local government level. The full-blown era of public culture and arts halls opened up in the 1980s~1990s, during which multi-purpose performance halls of a similar structure became universal around the nation. Public culture and arts halls of the uniform shape were distributed around the nation with no premise of genre characteristics or local environments for arts, and this was attributed to the cultural policies of the military regime. The Park Chung-hee regime proclaimed Yusin that was beyond the Constitution and enacted the Culture and Arts Promotion Act(September, 1972), which was the first culture and arts act in the nation. Based on the act, a five-year plan for the promotion of culture and arts(1973) was made and led to the construction of cultural facilities. "Public culture and arts" halls or "culture" halls were built to serve multiple purposes around the nation because the Culture and Arts Promotion Act, which is called the starting point of the nation's legal system for culture and arts, defined "culture and arts" as "matters regarding literature, art, music, entertainment, and publications." The definition became a ground for the current "multi-purpose" concept. The organization of Ministry of Culture and Public Information set up a culture and administration system to state its supervision of "culture and arts" and distinguish popular culture from the promotion of arts. During the period, former President Park exhibited his perception of "culture=arts=culture and arts" in his speeches. Arts belonged to the category of culture, but it was considered as "culture and arts." There was no department devoted to arts policies when the act was enacted with a broad scope of culture accepted. This ambiguity worked as a mechanism to mobilize arts in ideological utilizations as a policy. Against this backdrop, the Sejong Center for the Performing Arts, a multi-purpose performance hall, was established in 1978 based on the Culture and Arts Promotion Act under the supervision of Ministry of Culture and Public Information. There were, however, conflicts of value over the issue of accepting the popular music among the "culture and arts = multiple purposes" of the system, "culture ≠ arts" of the cultural organization that pushed forward its establishment, and "culture and arts = arts" perceived by the powerful class. The new military regime seized power after Coup d'état of December 12, 1979 and failed at its culture policy of bringing the resistance force within the system. It tried to differentiate itself from the Park regime by converting the perception into "expansion of opportunities for the people to enjoy culture" to gain people's supports both from the side of resistance and that of support. For the Chun Doo-hwan regime, differentiating itself from the previous regime was to secure legitimacy. Expansion of opportunities to enjoy culture was pushed forward at the level of national distribution. This approach thus failed to settle down as a long-term policy of arts development, and the military regime tried to secure its legitimacy through the symbolism of hardware. During the period, the institutional ground for public culture and arts halls was based on the definition of "culture and arts" in the Culture and Arts Promotion Act enacted under the Yusin system of the Park regime. The "multi-purpose" concept, which was the management goal of public performance halls, was born based on this. In this context of the times, proscenium performance halls of a similar structure and public culture and arts halls with a similar management goal were established around the nation, leading to today's performance art and culture in the nation.