• Title/Summary/Keyword: Power distribution control

Search Result 969, Processing Time 0.037 seconds

A Takagi-Sugeno fuzzy power-distribution method for a prototypical advanced reactor considering pump degradation

  • Yuan, Yue;Coble, Jamie
    • Nuclear Engineering and Technology
    • /
    • v.49 no.5
    • /
    • pp.905-913
    • /
    • 2017
  • Advanced reactor designs often feature longer operating cycles between refueling and new concepts of operation beyond traditional baseload electricity production. Owing to this increased complexity, traditional proportional-integral control may not be sufficient across all potential operating regimes. The prototypical advanced reactor (PAR) design features two independent reactor modules, each connected to a single dedicated steam generator that feeds a common balance of plant for electricity generation and process heat applications. In the current research, the PAR is expected to operate in a load-following manner to produce electricity to meet grid demand over a 24-hour period. Over the operational lifetime of the PAR system, primary and intermediate sodium pumps are expected to degrade in performance. The independent operation of the two reactor modules in the PAR may allow the system to continue operating under degraded pump performance by shifting the power production between reactor modules in order to meet overall load demands. This paper proposes a Takagi-Sugeno (T-S) fuzzy logic-based power distribution system. Two T-S fuzzy power distribution controllers have been designed and tested. Simulation shows that the devised T-S fuzzy controllers provide improved performance over traditional controls during daily load-following operation under different levels of pump degradation.

A Study of Control Algorithm For Series Active Power Filter Using Performance Function (성능함수를 이용한 직렬형 능동전력필터의 제어알고리즘에 관한 연구)

  • Ko Soo-Hyun;Kim Jin-Sun;Kim Young-Seok
    • Proceedings of the KIPE Conference
    • /
    • 2002.11a
    • /
    • pp.199-202
    • /
    • 2002
  • This paper suggests the control algorithm of a 3-phase 3-wire series active power filters which have harmonic voltage source and harmonic current source This suggested control algorithm can compensate harmonics which are generated by nonlinear load such as diode or thyristor converter and reactive power in 3-phase 3-wire power distribution system This control algorithm extracts a compensation voltage reference from performance function without phase transformation Therefore this control algorithm is simpler than any other conventional control algorithm. 3-phase 3-wire series active power filter and hybrid active power filter is manufactured and experiments are carried out for harmonic voltage source and harmonic current source to verify the effectiveness of presented control algorithm Experimental results are presented in this Paper, as well.

  • PDF

Power Decoupled Multi-Port Dual-Active-Bridge Converter Employing Multiple Transformers for DC Distribution Applications (복수의 변압기를 사용하여 독립 전력제어가 가능한 DC 배전용 다중포트 Dual-Active-Bridge 컨버터)

  • Kim, Inhyeok;Sim, Ju-Young;Lee, Jun-Young;Jung, Jee-Hoon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.25 no.4
    • /
    • pp.286-292
    • /
    • 2020
  • This study proposes a power decoupled multi-port dual-active-bridge (DAB) DC-DC converter employing multiple transformers. Conventional multiport DAB DC-DC converters experience a power coupling issue from the use of a single transformer, which essentially requires complex power decoupling control. To solve this issue, a multiport DAB DC-DC converter employing multiple transformers is proposed to decouple output power without additional complex control algorithms. The proposed converter uses multiple transformers that can expand output ports easily. Therefore, transformers and the proposed multi-port DAB converter can be designed simply. In addition, the number of coupling inductors can be reduced in the proposed three-port DAB converter compared with that in conventional multiport DAB converters. The power decoupling characteristics and equivalent circuit of the proposed converter are analyzed using theoretical model approaches. Finally, a 3-kW laboratory prototype is developed to verify the effectiveness of the proposed converter.

The Design of Control Algorithm for Unified Power Quality Compensator (3상 직병렬보상형 전력품질 보상장치(UPQC)의 제어 알고리즘 설계)

  • Jeon Jin Hong;Kim Tae Jin;Ryoo Hong Je;Kim Hwang Su
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.351-353
    • /
    • 2004
  • In recent years, customers and power supplies are interested in power quality. Demands of customers are change from standard quality of distribution power system to various high quality of distribution power system. so, it is necessary to apply power quality compensator. in our project, we develop the UPQC(Unfied Power Quality Compensator of 45kVA which compensates power factor and voltage sag, interruption. it is very frequently occurred power quality $problems^{[1-3]}$ As a series and shunt compensator, UPQC consists of two inverters with common do link capacitor bank. It compensates the current quality in the shunt part and the voltage quality in the series part. In this paper, we present the design and control algorithm for 4SkVA UPQC system. As a control algorithm is implemented by digital controller, we consider sample-and-hold of signals. In this simulation, we use EMTDC/PSCAD V3.0 software which can simulate instantaneous voltage and current.

  • PDF

The Control System Standardization for Airport Electric Power Receiving and Distribution Facility (공항 수.배전설비 제어시스템 표준화)

  • Song, Young-Joo;Choi, Hong-Kyoo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.4
    • /
    • pp.123-130
    • /
    • 2006
  • Airport facility is infrastructure that become external credit worthiness and linear measure of country competitive power. Among them, an airport electric power receiving and distribution facility is very important. In this paper, sorted domestic airline as 4 grades by code to accomplish standardization for airport electric power receiving and distribution facility. And established define and coverage about electric power receiving and distribution facility. And then analyze problem of existing airport and presents standardization. Finally, present standard single-line diagram by airport grade and system grade standard of airport electric power receiving and distribution facility

Development of an Integrated Control and Monitoring System for Emergency Power Generators (비상발전기 통합제어 및 감시시스템 개발)

  • 진강규;류길수;윤지근;유성호;김재환
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2001.05a
    • /
    • pp.192-196
    • /
    • 2001
  • These days, most of electric power facilities need high stability. Therefore integrated system has been required to monitor and control electronic power distribution system in fields at all times when the interruption of electric power has occurred. To construct this system, unit that convert and process the input signal from fields needed. And for control and monitoring from remote place MMI software is required. Lastly network equipments are required for real-time communications. So, in this paper, units for control and monitoring of emergency power generator and for electric power monitoring in normal electric power and interruption of electric power are developed. Also integrated remote system for monitoring in remote is developed.

  • PDF

A simplified method for the determination of the optimal operating patterns in system voltage-reactive power control (전압.무효전력제어에 있어서의 최적운전 목표상태의 간략결정법)

  • 송길영
    • 전기의세계
    • /
    • v.15 no.3
    • /
    • pp.1-7
    • /
    • 1966
  • The past several years have strongly anticipated the advent of a more integrated system control combining active power and voltage-reactive power controls. This paper presents a new approach to the intergrated system control with primary emphasis on the development of a new control method which combines the conventional economical load dispatching(ELD) and voltage-reactive power controls. The control method, in its fundamental principle, first determines the optimal active power allocation in accordance with the conventional ELD controller. By a proper manipulation of the remaining reactive power sources in the system, the control method then reduces the transmission losses of the system by the adjustment of system voltage distribution and also by the proper allotment of reactive power flows.

  • PDF

The effect of imperfect power control on the capacity of reverse channel in cellular CDMA system with antenna arrays (안테나 배열을 이용한 CDMA 셀룰라 시스템에서 불완전 전력제어가 역방향 채널 용량에 미치는 효과)

  • 김씨알;오성근
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.21 no.2
    • /
    • pp.471-482
    • /
    • 1996
  • In this paper, we analyze the effect of imperfect power control on the capacity of the reverse channel in CDMA cellular system with antenna arrays in the base station. For imperfect power control, we assume that the received power at the base station from the users within each cell has log-normal distribution, and we also consider the effect of imperfect power control of co-channel interferences which arise from both its own cell and outer cells. From the result of numerical analysis, we show that the degree of power control gives a great influence on the capacity of CDMA celluar system with antenna arrays, and also that antenna arrays at the base station can improve greatly the system capacity even when the power control is imperfect.

  • PDF

An Operation and Control Algorithm of Micro-grid (차세대전력공급네트워크(Micro-grid)의 운용제어앨고리즘)

  • Rho, Dae-Seok;Kim, Jae-Eon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.2
    • /
    • pp.232-239
    • /
    • 2007
  • There is an increasing concern to interconnect DG(Distributed Generation) units into a distribution system and operate and maintain the system power quality within a proper level to distribution companies, regional electricity utilities and industrial customers. Recently, this situation makes many experts estimate a next generation of distribution system which is composed of some micro-grids. But the proposed micro-grid is only mentioned as a small grid with some DG units, some power quality compensators, communication and control equipments. In this paper, a topology and an operation/control algorithm of the micro-grid which is able to supply the electricity with high reliability and quality, are proposed.

  • PDF

A study on the voltage rise of the inverter output terminal according to the low voltage Grid connection of solar power generation (태양광발전 저압연계시 인버터 출력단 전압상승에 대한 연구)

  • Cho, Kang-yeon;Eo, Ik-soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.11
    • /
    • pp.746-752
    • /
    • 2020
  • As environmental issues have been taken seriously, the number of solar power generation facilities has rapidly increased in Korea. The voltage at the output stage of an inverter increases in a system that connects a small-capacity photovoltaic power generation to low-voltage power distribution. This degrades the quality of the low-voltage distribution system and adversely affects the load facility. In this study, a solution was obtained to increase the voltage at the output stage of the solar inverter according to the connection of the low-voltage distribution system. The voltage can be controlled by using reactive power factor control inverters. If the secondary tap is adjusted, the voltage can be adjusted to about 15 V, but there is a problem in that the tap is not adjusted unless the KEPCO distribution regulation voltage is out of the range of 220±13V. If the number of inverters is limited, the inverter can be started within the inverter overvoltage range. If it is connected to three phases, the voltage is distributed. The results indicated that power factor control and active voltage control inverters were easy to apply in the field.