• Title/Summary/Keyword: Power decoupling

Search Result 203, Processing Time 0.026 seconds

Resonance Device Design of Bidirectional DC-DC Converter for Active Power Decoupling of Photovoltaic AC Module (태양광 AC 모듈의 능동 디커플링을 위한 양방향 DC-DC 컨버터의 공진 소자 설계)

  • Kim, Mi-Na;Noh, Yong-Su;Kim, Jun-Gu;Lee, Tae-Won;Jung, Yong-Chae;Won, Chung-Yuen
    • Proceedings of the KIPE Conference
    • /
    • 2012.11a
    • /
    • pp.103-104
    • /
    • 2012
  • In the AC module system, mismatch problem between AC power and constant input power is occurred. To solve this problem, electrolytic capacitor is utilized for diminishing power pulsation in PV side. However, it has disadvantages of low life span and weak in temperature. Decoupling method has been studied to reduce the capacitance and replaces electrolytic capacitor to film capacitor. This paper proposes design method for decoupling circuit which bidirectional DC-DC converter using soft switching. Proposed system is verified by design optimization and simulation results.

  • PDF

A Study on Implementation of Active Power Decoupling Circuit for Boost Type PFC Rectifier with Low DC Link Capacitance (낮은 직류 링크 커패시턴스를 갖는 승압형 PFC 정류기를 위한 Active Power Decoupling 회로 구현에 관한 연구)

  • Hwang, Deok-hwan;Lee, Jungyong;Cho, Younghoon;Choe, Gyu-ha
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.246-247
    • /
    • 2017
  • 단상 ac/dc, dc/ac 시스템의 경우, ac와 dc사이의 전력 불균형으로 인해 double line frequency ripple power가 발생한다. 이는 harmonic disturbance을 야기시킨다. 일반적으로 전력 리플을 줄이기 위하여 dc-link에 용량이 큰 전해 커패시터를 사용하는데, 용량이 큰 전해 커패시터는 높은 equivalent series resistance(ESR)을 가지며, 상대적으로 짧은 수명을 갖는 한계를 갖는다. 본 논문은 active power decoupling을 추가함으로써 전해 커패시터를 용량이 작은 필름 커패시터로 대체한 회로 구조를 제시한다. 그리고 dc-link 커패시터 선정방법, 설계한 제어기의 성능과 부하 변동에 따른 실험을 PSIM 시뮬레이션으로 확인하고 실험을 통해 검증한다.

  • PDF

Grid Voltage Estimation Method for Modular Plug-in Active Power Decoupling Circuits (모듈형 플러그인 능동전력디커플링 회로를 위한 계통전압 추종 방법)

  • Kim, Dong-Hee;Kim, Jeong-Tae;Park, Sung-Min;Chung, Gyo-Bum
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.26 no.4
    • /
    • pp.294-297
    • /
    • 2021
  • A grid voltage estimation method for modular plug-in active power decoupling (APD) circuits is proposed in this study as direct replacements of electrolytic capacitors. Since modular plug-in APD circuits cannot have additional grid voltage sensors and should be operated independently without information exchange with the front-end converter, it is impossible to obtain the phase information of the grid directly. Therefore, the proposed method uses the second-order harmonic component of the DC-link voltage to estimate the grid voltage necessary to control the APD circuit. By employing the proposed method, the concept of modular plug-in APD circuits can be realized and implemented without direct detection of the grid voltage. The experimental results based on hardware-in-the-loop simulation (HILS) validate the effectiveness of the proposed control method.

Immunity Test for Semiconductor Integrated Circuits Considering Power Transfer Efficiency of the Bulk Current Injection Method

  • Kim, NaHyun;Nah, Wansoo;Kim, SoYoung
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.14 no.2
    • /
    • pp.202-211
    • /
    • 2014
  • The bulk current injection (BCI) and direct power injection (DPI) method have been established as the standards for the electromagnetic susceptibility (EMS) test. Because the BCI test uses a probe to inject magnetically coupled electromagnetic (EM) noise, there is a significant difference between the power supplied by the radio frequency (RF) generator and that transferred to the integrated circuit (IC). Thus, the immunity estimated by the forward power cannot show the susceptibility of the IC itself. This paper derives the real injected power at the failure point of the IC using the power transfer efficiency of the BCI method. We propose and mathematically derive the power transfer efficiency based on equivalent circuit models representing the BCI test setup. The BCI test is performed on I/O buffers with and without decoupling capacitors, and their immunities are evaluated based on the traditional forward power and the real injected power proposed in this work. The real injected power shows the actual noise power level that the IC can tolerate. Using the real injected power as an indicator for the EMS test, we show that the on-chip decoupling capacitor enhances the EM noise immunity.

Hybrid Fuzzy PI-Control Scheme for Quasi Multi-Pulse Interline Power Flow Controllers Including the P-Q Decoupling Feature

  • Vural, Ahmet Mete;Bayindir, Kamil Cagatay
    • Journal of Power Electronics
    • /
    • v.12 no.5
    • /
    • pp.787-799
    • /
    • 2012
  • Real and reactive power flows on a transmission line interact inherently. This situation degrades power flow controller performance when independent real and reactive power flow regulation is required. In this study, a quasi multi-pulse interline power flow controller (IPFC), consisting of eight six-pulse voltage source converters (VSC) switched at the fundamental frequency is proposed to control real and reactive power flows dynamically on a transmission line in response to a sequence of set-point changes formed by unit-step reference values. It is shown that the proposed hybrid fuzzy-PI commanded IPFC shows better decoupling performance than the parameter optimized PI controllers with analytically calculated feed-forward gains for decoupling. Comparative simulation studies are carried out on a 4-machine 4-bus test power system through a number of case studies. While only the fuzzy inference of the proposed control scheme has been modeled in MATLAB, the power system, converter power circuit, control and calculation blocks have been simulated in PSCAD/EMTDC by interfacing these two packages on-line.

Stability Analysis of FCHEV Energy System Using Frequency Decoupling Control Method

  • Dai, Peng;Sun, Weinan;Xie, Houqing;Lv, Yan;Han, Zhonghui
    • Journal of Power Electronics
    • /
    • v.17 no.2
    • /
    • pp.490-500
    • /
    • 2017
  • Fuel cell (FC) is a promising power supply in electric vehicles (EV); however, it has poor dynamic performance and short service life. To address these shortcomings, a super capacitor (SC) is adopted as an auxiliary power supply. In this study, the frequency decoupling control method is used in electric vehicle energy system. High-frequency and low-frequency demand power is provided by SC and FC, respectively, which makes full use of two power supplies. Simultaneously, the energy system still has rapidity and reliability. The distributed power system (DPS) of EV requires DC-DC converters to achieve the desired voltage. The stability of cascaded converters must be assessed. Impedance-based methods are effective in the stability analysis of DPS. In this study, closed-loop impedances of interleaved half-bridge DC-DC converter and phase-shifted full-bridge DC-DC converter based on the frequency decoupling control method are derived. The closed-loop impedance of an inverter for permanent magnet synchronous motor based on space vector modulation control method is also derived. An improved Middlebrook criterion is used to assess and adjust the stability of the energy system. A theoretical analysis and simulation test are provided to demonstrate the feasibility of the energy management system and the control method.

Synchronous PI Decoupling Control Scheme for DVR against a Voltage Sag in the Power System

  • Kim, Myung-Bok;Lee, Seung-Hoon;Moon, Gun-Woo;Youn, Myung-Joong
    • Journal of Power Electronics
    • /
    • v.4 no.3
    • /
    • pp.180-187
    • /
    • 2004
  • This paper proposes a new control strategy for the dynamic voltage restorer (DVR). It is based on a synchronous PI decoupling control strategy which features fast response time and low steady state error. Therefore, the proposed control strategy produces faster action time against voltage sag and guarantees more than enough compensation for reduced supply voltage. Experimental results, implemented with the TMS320C3${\times}$DSP control unit, are shown to validate the effectiveness of the proposed control strategy.

Multilayer Power Delivery Network Design for Reduction of EMI and SSN in High-Speed Microprocessor System

  • Park, Seong-Geun;Kim, Ji-Seong;Yook, Jong-Gwan;Park, Han-Kyu
    • Journal of electromagnetic engineering and science
    • /
    • v.2 no.2
    • /
    • pp.68-74
    • /
    • 2002
  • In this paper, a pre-layout design approach for high-speed microprocessor is proposed. For multilayer PCB stark up configuration as well as selection and placement of decoupling capacitors, an effective solution for reducing SSN and EMI is obtained by modeling and simulation of complete power distribution system. The system model includes VRM, decoupling capacitors, multiple power and ground planes for core voltage, vias, as well as microprocessor. Finally, the simulation results are verified by measurements data.

A Study on PV AC-Module with Active Power Decoupling and Energy Storage System

  • Won, Dong-Jo;Noh, Yong-Su;Lim, Hong-Woo;Won, Chung-Yuen
    • Journal of Power Electronics
    • /
    • v.16 no.5
    • /
    • pp.1894-1903
    • /
    • 2016
  • In general, electrolytic capacitors are used to reduce power pulsations on PV-panels. However, this can reduce the reliability of the PV AC-module system, because electrolytic capacitors have a shorter lifetime than PV-panels. In addition, PV-panels generate irregular power and inject it into the grid because the output power of a PV-panel depends on the surrounding conditions such as irradiation and temperature. To solve these problems, a grid-connected photovoltaic (PV) AC-module with active power decoupling and energy storage is proposed. A parallel bi-directional converter is connected to the AC module to reduce the output power pulsations of PV-panels. Thus, the electrolytic capacitor can be replaced with a film capacitor. In addition, the irregular output power due to the surrounding conditions can be regulated by using a parallel energy storage circuit. To maintain the discontinuous conduction mode at low irradiation, the frequency control method is adopted. The design method of the proposed converter and the operation principles are introduced. An experimental prototype rated at 125W was built to verify the performance of the proposed converter.

Complex Vector Modeling and Series Decoupling Current Control Strategy of High-Power L/LCL Type Grid-Connected Converter Under Low Switching Frequency

  • Wang, Yingjie;Jiao, Lanyi;Yang, Bo;Wang, Wenchao;Liu, Haiyuan
    • Journal of Power Electronics
    • /
    • v.18 no.6
    • /
    • pp.1879-1888
    • /
    • 2018
  • With power level of grid-connected converters rising, the switching frequency of the switching devices is commonly greatly reduced to improve its power capacity. However, this results in serious couplings of the dq current components, which leads to degradation of the static and dynamic performances of grid-connected converters and fluctuations of the reactive power in dynamic processes. In this paper, complex vector models under low switching frequency are established for an L/LCL grid-connected converter, and the relationship between the switching frequency and the coupling degree is analyzed. In addition, a series decoupling current control strategy is put forward. It is shown that the proposed control strategy can eliminate the couplings, improve the performances and have good robustness to parameter variations through static and dynamic characteristics analyses and a sensitivity analysis. Experimental and simulation results also verify the correctness of the theoretical analyses and the superiority of the proposed control strategy.