Variance of Harmonics Element due to Linear & Non-linear Load Quantity (선형 및 비선형 부하량에 따른 고조파 성분의 변화)

  • Kim, Jong-Gyeom;Son, Hong-Gwan;Lee, Eun-Ung
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.8
    • /
    • pp.441-448
    • /
    • 2002
  • Harmonics studies have been an important aspect of power conversion system analysis and design in recent years. Harmonics using power conversion device, have a harmful effect on power qualify. Nonlinear load such as converter causes harmonic and effects self & other system. There are linear and nonlinear loads in the end-user application. For filter design to reduce harmonics, it is important to understand how loads interact with each other. In this paper, effects on the power conversion system at the low voltage local bus are discussed.

Analysing and comparing efficiency of harmonic reduction equipment for Induction Motor (유도전동기의 고조파 저감장치 성능 비교 분석)

  • Park, Yang-Birm;Kim, Doo-Hyun
    • Journal of the Korean Society of Safety
    • /
    • v.20 no.3 s.71
    • /
    • pp.47-52
    • /
    • 2005
  • Recently, power conversion equipment increased rapidly makes a lot of harmonics. Thus, it is growing that wrong operation and break down of sensitive devices. There are two kinds of causes of harmonics. One of them is lots of power conversion equipment as modem controller, inverter, converter and SWS(Switching Mode Power Supply). Another is nonlinear operating machines as transformer and motor. The more nonlinear loads like them grow, the more serious problems as harmonic current to source and low power factor because of increasing reactive power grow. It is installed for reactor and L-C Filter to decrease harmonic in general. This paper analysis and compares two of characteristics and harmonic from reactor and L-C Filter with operation of induction motor and power conversion equipment. In the result, L-C Filter more improves unbalance rate and THD than reactor.

Hybrid Power Filter for the Zero Sequence Harmonics Reduction in Neutral Line (중성선 영상 고조파 전류 저감을 위한 하이브리드 전력 필터)

  • Ji, Young-Hyok;Park, Sang-Hoon;Kim, Jae-Hyung;Won, Chung-Yuen;Song, Sang-Hoon
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.472-474
    • /
    • 2008
  • According to the development of power switching device technology, the power conversion system is used from the small electric power units to the large industrial instruments. These instruments are operated as harmonic sources in the grid and the harmonics cause zero sequence harmonics in the neutral line. To reduce zero sequence harmonics, the zigzag transformer is used conventionally. But the zigzag transformer can reduce only 60~70% of harmonics. In this paper, hybrid power filter for zero sequence harmonics reduction and the harmonic detection method are proposed.

  • PDF

A Study on the Reduction of harmonics by Current type PWM - Inverter (전류형 PWM 인버터에 의한 고조파 저감에 관한 연구)

  • Lee, Kye-Ho;Jang, Young-Hak;Yang, Seung-Hak;Jung, Young-Gook
    • Proceedings of the KIEE Conference
    • /
    • 1987.11a
    • /
    • pp.359-361
    • /
    • 1987
  • It is known that the reactive component of AC power in the Power system gives no energy to outside and causes enlargement of power apparatus, voltage fluctuation and unstability of power system. The power conversion system and control system which are composed of power semiconductor devices such as Thyrisor, transistor, GTO and so on have been appeared as new sources of Harmonics. So the reduction of harmonics in power semiconductor system is one of impending problems on the point of energy conservation and improvement of power factor. This paper treates the fundamental review of the harmonics reduction by Current type PWM-Inverter. This Inverter-detects not only the fundamental wave but also that of all harmonics created in the power semiconductor system and is scheduled to control by sampled value.

  • PDF

A Novel Photovoltaic Power Generation System including the Function of Shunt Active Filter

  • Park, Minwon;Seong, Nak-Gueon;Yu, In-Keun
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.3B no.2
    • /
    • pp.103-110
    • /
    • 2003
  • With significant development of power electronics technology, the proliferation of nonlinear loads such as static power converters has deteriorated power quality in power transmission and distribution systems. Notably, voltage harmonics resulting from current harmonics produced by the nonlinear loads have become a serious problem in many countries. Many photovoltaic power generation systems installed in building systems have harmonics that are the worst object for distribution systems as a utility interactive system, and it tends to spread out continuously. Proposed and implemented in this paper is a multi-function inverter control strategy that allows a shunt active filter function to the power inverter of the photovoltaic power generation system established on a building system. The effectiveness of the proposed system is demonstrated through the simulation of a hypothetical power system using PSCAD/EMTDC.

Characteristic Analysis of Power Compensation Condenser Considering Voltage Harmonics (전압 고조파를 고려한 역률보상용 콘덴서의 특성 분석)

  • Kim, Jong-Gyeum;Lee, Dong-Ju
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.2
    • /
    • pp.141-145
    • /
    • 2010
  • Most of the industrial loads includes the non-linear load as well as the linear load because there are many kinds of power conversion equipments at the input stage of the load in distribution network. The non-linear load causes the distortion of voltage waveform at PCC because the non-linear load generates the harmonic current. As a result, various voltage harmonics are existed at PCC depending on the current harmonics from the non-linear load. And, a series reactor is generally connected to the power capacitor in series to attenuate the distortion of voltage waveform and to reduce an inrush current of power capacitor. Also, harmonic current of power capacitor is highly dependent on the series reactor because it is operated with the power capacitor as a passive filter against nonlinear loads. Then, these capacitors might be damaged by the excessive voltage and current harmonic components. In this paper, we presented how to select the capacitor and series reactor to meet the requirement of the voltage distortion at PCC and analyzed the voltage, current and capacity rating of the power capacitor by the computer simulation to ensure the safe operation of power capacitor when the voltage harmonics at PCC are existed. Also, the analysis data were compared with the experimental measurements for the verification.

Harmonics analysis based on a frequency domain in Electric Feeding System (전기철도 급전시스템의 주파수 기반모델을 이용한 고조파 해석)

  • Han Moonseob;Lee Jangmu;Jung Hosung;Kim Joorak
    • Proceedings of the KSR Conference
    • /
    • 2004.06a
    • /
    • pp.1315-1318
    • /
    • 2004
  • Each feeding power is transformed 3 phases of KEPCO through SCOTT transformer and operate a electric train in AC Feeding system of electric railway. Nowaday a power conversion system, installed inside the train, generate a harmonics and has a effect on a power quality and it is necessary to install a countermeasures. This report is proposed a new technique to simulate a power system based on frequency model. The result is resonable relatively with a experimental one.

  • PDF

Measurement and Analysis Harmonics Using DSP (DSP를 이용한 고조파 측정 및 분석)

  • Lee, Sang-Ik;Yoo, Jae-Geun;Jeon, Jeong-Chay
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.178-180
    • /
    • 2002
  • Limitation countermeasure on harmonics occurred by power conversion installation, motor speed control equipment, and so on of power system is very important problem, and first of all, accuracy harmonics analysis in system is required for appropriate limitation counterplan. Analysis and judgement on power system harmonic by measurement are needed because analysis by mathematical model generally used for these harmonic analysis, if nonlinear ingredient is included in system, is not relatively correct. So, in this paper, system to measure and analyze harmonic by installing it in a power system, using DSP(Digital Signal Processor), is designed and developed. Also, it's performance is verified by installing it in the system that harmonics occurred.

  • PDF

A study of power filter for conversion of 3 phase PWM waveform to grid power line (전력용 3상 PWM 파형의 상용전원 변환용 Filter 연구)

  • Yea, Hwan-Je;Sea, Young-Taek;Oh, Chul-Soo
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.1016-1019
    • /
    • 1993
  • A low-pass L-C filter has been adopted for conversion of frequency variable 3 phase PWM waveform to a grid power line and it is used for attenuation of harmonics in the VSI PWM Inverter. A optimum design of the L, C parameters was derived. The result of the study show that the inductor L seems to have a certain air gap for linear I-V characteristics and the resonant frequency of the filter must be set below the 5th harmonics of the grid power line. Further, the voltage drop in L must be within a adequate limit compared to grid power voltage.

  • PDF

Analysis of Impedance Performance for Condenser by Harmonic Current Source (고조파 전류원에 의한 콘덴서 임피던스 특성 해석)

  • Kim, Jong-Gyeum;Park, Young-Jeen
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.4
    • /
    • pp.57-64
    • /
    • 2011
  • Most of the user has been used linear load and non-linear load. The former is usually inductive load which is needed power factor compensation, the latter is power conversion system device. Actually two kinds of load is used together in the customer application. Generally capacitor is used for power-factor compensation of inductive load and reduction harmonics of non linear load with reactor. Non-linear load generates harmonic current for its energy conversion process. If harmonic current pass along the low impedance side of distribution system, the magnification of voltage and current is appeared by the series and parallel resonance. As a result, condenser has received a bitter electrical stress by the harmonic component. In this paper, we analyzed that how resonance is changed by the 5-th harmonic current pattern and proposed an alternative plan for non-magnification.