• 제목/요약/키워드: Power conditioning operation

검색결과 227건 처리시간 0.022초

지열원 히트펌프시스템의 실사용을 통한 난방성능연구 (Heating Performance of a Ground Source Heat Pump System through Actual Operation)

  • 구경민;정영만;황유진;이재근;장세용;김인규;진심원;이동혁
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.788-793
    • /
    • 2008
  • This paper presents the heating performance of a water-to-refrigerant type ground source heat pump system (GSHP) installed in a school building. The evaluation of the heating performance has been conducted under the actual operating conditions of GSHP system in the winter. Ten units with the capacity of 10 HP each were installed in the building. Also, a closed vertical typed-ground heat exchanger with 24 boreholes of 175 m in depth was constructed for the GSHP system. For analyzing the heating performance of the GSHP system, we monitored various operating conditions, including the outdoor temperature, the ground temperature, and the water temperature of inlet and outlet of the ground heat exchanger. Simultaneously, the heating capacity and the input power were evaluated for determining the heating performance of the GSHP system. The average heating coefficient of performance (COP) of the heat pump was found to be 5.1 at partial load of 46.9%, while the overall system COP was found to be 4.2.

  • PDF

핵연료 노내조사시험설비의 시공 현황 (The Construction Status of Fuel Test Loop Facility)

  • 박국남;이정영;김학노;유현재;유성연
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.305-309
    • /
    • 2007
  • FTL(Fuel Test Loop) is a facility that confirms performance of nuclear fuel at a similar irradiation condition with that of nuclear power plant. FTL construction work began on August, 2006 and ended on March, 2007. During Construction, ensuring the worker's safety was the top priority and installation of the FTL without hampering the integrity of the HANARO was the next one. The installation works were done successfully overcoming the difficulties such as on the limited space, on the radiation hazard inside the reactor pool, and finally on the shortening of the shut down period of the HANARO. The Commissioning of the FTL is to check the function and the performance of the equipment and the overall system as well. The FTL shall start operation with high burn up test fuels in early 2008 if the commissioning and licensing progress on schedule.

  • PDF

중앙난방방식을 지역난방.소형열병합난방방식으로 전환시의 경제성 비교 분석 (Analysis for the Economic efficiency of District Heating and Gas Engine Co-generation System comparing with Central Heating System)

  • 김규생;이상혁;홍경표;원영재
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.459-465
    • /
    • 2007
  • This study was conducted to calculate the LCC of a apartment complex with a type of heating system, district heating and cogeneration system. For the purpose of analyzing LCC according to size of apartment complex, 500, 1,500 and 4,000 houses of model apartment selected. This research performs design of heating system and the life cycle cost analysis including an initial cost, energy cost, maintenance and operation cost, replacement cost and renovation cost during the project period(15years). According to the calculated results, 1) Initial cost of cogeneration system with 500, 1500 and 4000 houses is higher than district heating system each of 20%, 13%, 12%. 2) In case of cogeneration system, the payback period by electric generation is 5.21, 4.92 and 4.47 years and saving cost was calculated 29 billion won, 94 billion won and 262 billion won after payback period. 3) Cogeneration system LCC was 1.12, 1.07 and 1.06 times larger than district system with the size of apartment complex. According to the case of this study district heating system is more efficient than cogeneration system in terms of the reduction of LCC. 4) Gas Engine Co-generation System is more efficient than other systems because it can collect progressive part from electric charge progressive stage system. However, the efficiency is decreasing because of raising of fuel bills(LNG) and lowering of power rate for house use. Especially the engine is foreign-made so the cost of maintenance and repair is high and the technical expert is short. 5) District heating is also affected by fuel bills so we should improve energy efficiency through recovering of waste heat(incineration heat, etc.). Also, we should supply district cooling on the pattern of heat using of let the temperature high in winter and low in summer.

  • PDF

하이브리드 자동차 에어컨용 전동식 압축기 모터 시스템의 열유동 해석 연구 (A Study on the Thermo-Flow Analysis of Air Conditioning Electric Compressor Motor System for Hybrid Electric Vehicles)

  • 김성철
    • 한국산학기술학회논문지
    • /
    • 제14권2호
    • /
    • pp.592-597
    • /
    • 2013
  • 인버터 일체형 전동식 압축기 내부의 모터 및 인버터에서 발생된 열은 차가운 냉매에 의해 냉각되기 때문에 열적인 문제가 거의 발생하지 않는다. 하지만, 압축기 모터 및 인버터의 열전달 성능은 압축부와의 상호 열전달에 의하여 압축기 성능에 영향을 미친다. 또한 외기 환경 및 시스템 운전조건에 따라, 모터 및 인버터의 온도 증가는 이러한 모터 시스템의 출력 밀도에 영향을 미치고, 특히 인버터는 온도 상한치 관리에 의해 작동이 멈추어질 수 있다. 본 연구에서는 전동식 압축기 모터 시스템의 열유동 해석을 수행하였고, 모터 및 인버터의 방열성능 향상에 대해 분석하였다. 현 모델의 해석 결과는 압축기 운전영역에서 모터가 전반적으로 낮은 온도 경향을 나타내었으며, 인버터의 경우는 고속조건에서 관리 온도인 $85^{\circ}C$ 이내 범위를 만족하지만, 저속 가혹조건에서 제한 온도를 $10^{\circ}C$ 정도 초과하였다. 따라서 가혹 운전조건에서의 방열 문제를 해결하기 위해, 압축기 유로개선 뿐만 아니라 모터 및 인버터의 발열 저감기술의 개발이 요구된다.

PR제어기를 이용한 단상 계통 연계형 태양광 인버터 설계 (PR Controller Based Current Control Scheme for Single-Phase Inter-Connected PV Inverter)

  • 부우충기엔;성세진
    • 한국산학기술학회논문지
    • /
    • 제10권12호
    • /
    • pp.3587-3593
    • /
    • 2009
  • 최근 태양광 시스템에서는 기존의 태양광 시스템을 계통과 전원으로 상호 접속하는 것에 대한 연구에 관심이 모아지고 있다. 단상, 삼상 시스템에 관계없이 태양광 시스템에서 태양광 인버터는 계통연계 동작에 중요한 역할을 하기 때문에 전체 시스템에서 핵심요소로 고려된다. 태양광 인버터를 제어하기 위해서는 부하 전류 조절이 핵심요소 중 하나이다. 일반적으로 태양광 인버터에서 이용되는 PI 제어기는 정상상태 오차와 왜란에 취약하다는 단점을 가지고 있기 때문에 실제 시스템에 완벽하게 적용하기에는 무리가 있다. 특히, 이는 고주파영역에서의 PI와 PR 제어기의 성능을 비교해보면 알 수 있다. 이 논문에서 제시된 PR 제어기는 무한 이득을 교류 기본파 성분에 넣을 수 있기 때문에 PR 제어기는 회전좌표계의 PI 제어기에서 사용되는 디커플링 기법과 복잡한 변환 없이 제로 정상상태오차에 도달할 수 있다. 그렇기 때문에 이 논문에서는 PI 제어기를 대체하는 이론적 분석을 통해 PR 제어기를 설계하였다. 논문에 제시되어 있는 이론을 바탕으로 한 PR 제어기를 고정 소수점 연산방식의 32비트 마이크로컨트롤러 DSP320F2812를 기반으로 한 3kW 프로토타입 태양광 인버터에 적용, 평가하였다. 또한 태양광 인버터의 제어 성능을 시뮬레이션과 실험결과를 통하여 보여주고 검증하였다.

단상 계통 연계형 태양광 인버터에 사용되는 PI 와 PR 전류제어기의 비교 분석 (Comparison of PI and PR Controller Based Current Control Schemes for Single-Phase Grid-Connected PV Inverter)

  • 부우충기엔;성세진
    • 한국산학기술학회논문지
    • /
    • 제11권8호
    • /
    • pp.2968-2974
    • /
    • 2010
  • 태양광 인버터는 계통과 태양광 시스템 사이의 공통 접속점에 고조파, 플리커, 고주파 노이즈가 없는 고품질 전력을 공급하는 핵심적인 역할을 한다. 일반적으로 비례-적분 (PI: Proportional Integral) 제어기는 정상상태 오차와 낮은 외란 제거 능력으로 인하여 교류 계통에서 만족할만한 성과를 얻지 못하나, 현장에서 이득 설정이 용이하므로 일반적으로 전압형 인버터 (VSI)에서 이용된다고 알려져 있다. 이 논문에서는 산업계에서 일반적으로 사용되는 비례-적분 제어기와 교류 계통의 상용주파수에서의 무한대의 이득 값을 가지며, 정상상태 에러 발생을 제거하며, 정지 좌표계에서 구현할 수 있는 비례-이득 (PR: Proportional Resonant) 제어기의 동작 원리, 설계 기법 등을 비교 분석하였다. PI와 PR 제어기의 분석 결과를 시뮬레이션과 실험을 통하여 그 타당성을 증명하였다. 두 제어기는 32-비트 고정소수점 연산을 하는 TMS320F2812 DSP 프로세서를 이용하여 구현하였고, 3kW 실험용 프로토타입 태양광 인버터를 제작하여 그 성능을 확인하였다.

냉동시스템 고장 진단 및 고장유형 분석을 위한 3단계 분류 알고리즘에 관한 연구 (A study on the 3-step classification algorithm for the diagnosis and classification of refrigeration system failures and their types)

  • 이강배;박성호;이희원;이승재;이승현
    • 한국융합학회논문지
    • /
    • 제12권8호
    • /
    • pp.31-37
    • /
    • 2021
  • 산업의 발전으로 도시화로 인해 건물의 규모가 커지면서, 건물의 공기 정화 및 쾌적한 실내 환경을 유지의 필요성 또한 증가하고 있다. 냉동 시스템의 모니터링 기술의 발전으로 건물 내에 발생하는 전력 소모량을 관리할 수 있게 되었다. 특히 상업용 건물에서 발생하는 전력 소모량 중 약 40%가 냉동 시스템에서 일어난다. 따라서 본 연구 냉동시스템 고장진단 알고리즘을 개발하기 위해서 냉동시스템의 구조를 이해하고, 냉동 시스템의 운영과정에서 발생하는 데이터를 수집 분석하여 다양한 유형과 심각도를 가지는 고장 상황을 조기에 신속하게 탐지 분류하고자 하였다. 특히 분류가 어려운 고장 유형들의 분류 정확도를 향상시키기 위하여 3단계 진단 및 분류 알고리즘을 개발하여 제안하였다. 다수의 실험과 초모수 (hyper parameter) 최적화 과정을 거쳐 각 단계에 적합한 분류 모형으로 SVM과 LGBM에 기반 한 모형을 제시하였다. 본 연구에서는 고장에 영향을 미치는 특성을 최대한 보존하면서, 선행연구에서 어려움을 겪었던 냉매 관련 고장을 포함한 모든 고장 유형을 우수한 결과로 도출하였다.