• Title/Summary/Keyword: Power compensator

Search Result 609, Processing Time 0.024 seconds

The Study of Fast Frequency Measurement Technique for Protection Relay (계전기를 위한 고속의 주교수 계측 알고리즘)

  • Kim, Beung-Jin;Lee, Chang-Ho;Park, Jong-Chan
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.211-213
    • /
    • 2005
  • In this paper, the frequency compensator for digital protective relay is introduced. Due to sudden appearance of generation-load or fault in power system, the frequency can deviate from its nominal value. The Orthogonal filter adopted to digital protective relay is exposed to the problem. Therefore, the frequency variation makes a difficult to protective function and power measurement in digital protective relay. The essential property of the proposed algorithm presented is its outstanding immunity to both signal orthogonal component magnitudes and DFT filter gain variations which ensures below 0.05Hz accuracy of estimation. Additionally, the proposed method has excellent characteristics with low signal sampling rate. Based on the frequency estimation, author design under frequency protection relay for generator and verifies its performance with several experimental tests.

  • PDF

Recursive Design of Nonlinear Disturbance Attenuation Control for STATCOM

  • Liu Feng;Mei Shengwei;Lu Qiang;Goto Masno
    • International Journal of Control, Automation, and Systems
    • /
    • v.3 no.spc2
    • /
    • pp.262-269
    • /
    • 2005
  • In this paper, a nonlinear robust control approach is applied to design a controller for the Static Synchronous Compensator (STATCOM). A robust control dynamic model of STATCOM in a one-machine, infinite-bus system is established with consideration of the torque disturbance acting on the rotating shaft of the generator set and the disturbance to the output voltage of STATCOM. A novel recursive approach is utilized to construct the energy storage function of the system such that the solution to the disturbance attenuation control problem is acquired, which avoids the difficulty involved in solving the Hamilton-Jacobi-Issacs (HJI) inequality. Sequentially, the nonlinear disturbance attenuation control strategy of STATCOM is obtained. Simulation results demonstrate that STATCOM with the proposed controller can more effectively improve the voltage stability, damp the oscillation, and enhance the transient stability of power systems compared to the conventional PI+PSS controller.

3D CAD Modeling of a Hydraulic Motor-Load System and Adaptive Control (유압모터-부하계의 3D CAD 모델링 및 적응제어)

  • Cho, S.H.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.8 no.2
    • /
    • pp.23-28
    • /
    • 2011
  • This paper investigates the motion control of a hydraulic motor-load system using the Simple Adaptive Control (SAC) method. The plant transfer function has been modelled mathematically. The open-loop responses have been obtained experimentally in order to identify the design parameters of transfer function. The hydraulic motor-load system has been modelled using the 3D CAD and imbedded in the hydraulic circuit simulation program to verify the overall performance. The experimental results confirm that the SAC method gives a good tracking performance compared to the PID control.

Position Control of an Electro Hydraulic Actuator Using Adaptive Control Method (적응제어 기법을 이용한 전기-유압 액츄에이터의 위치제어)

  • Cho, S.H.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.7 no.3
    • /
    • pp.1-6
    • /
    • 2010
  • This paper deals with the issue of simple adaptive position control for a pump-controlled cylinder system. A fixed displacement pump is utilized instead of servo valve and its speed is controlled by AC motor. The whole control system is composed of a pair of interconnected subsystems, that is, a feedback control system and a feedforward control system. From experiments it is shown that position control using simple adaptive control can accomplish significant reduction in position tracking error comparing to a conventional PID control.

  • PDF

A SIMPLE REACTIVE/HARMONIC COMPENSATION METHOD WITH VOLTAGE TYPE CONVERTER (전압형 컨버터를 이용한 무효/고조파 보상을 위한 선형 제어 방법)

  • Kim, Hyo-Jin;Jeong, Seung-Gi;Choi, Jae-Ho;Park, Min-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1989.11a
    • /
    • pp.305-309
    • /
    • 1989
  • This paper presents a simple method to compensate reactive/harmonic current components in power lines, with voltage type current controlled converter. The method proposed differs from conventional methods in that it does not rely on explict evaluation of active power. Instead, the closed-loop control of the do link voltage of the compensator plays a major role in adjusting the compensation current. It is shown that the system can be modelled as a simple linear system, which facilitates th analytical approach to the system characteristics. The dynamic performances are examined through the digital simulation and some aspects on the controller design are discussed. Experimental results showed good agreement with the anticipate performance

  • PDF

Development of EMTDC model for Seo-deagu SVC (서대구 SVC의 EMTDC 모델 개발)

  • Kim, D.H.;Son, K.M.;Lee, T.G.;Yoon, Y.B.;Lee, J.;Jang, G.S.
    • Proceedings of the KIEE Conference
    • /
    • 2000.11a
    • /
    • pp.217-219
    • /
    • 2000
  • Recently a static var compensator(SVC) is installed at Seo-deagu Substation. It is a power system controller using power electronics commonly called Flexible AC Transmission Systems(FACTS). This paper presents the characteristics and configuration of the Seo-deagu SVC. This paper discusses the modeling aspect of the Seo-deagu SVC systems. EMTDC simulation model of the Seo-deagu SVC is developed and verified.

  • PDF

Subtransmission Reduction for FAGTS Site Selection in Large Power System (대규모 전력계통에서의 하위 송전계통 축약을 이용한 FACTS 위치선정 연구)

  • Chang, Byung-Hoon;Choo, Jin-Boo;Kwon, Sea-Hyuk
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1302-1304
    • /
    • 1999
  • This Paper Proposes the FACTS site selection method using subtransmission system reduction. A general method which uses the sensitivity of the variation in voltage and reactive Power has been used to determine the location of shunt type FACTS device, but there is a difficulty to find a proper location due to the overestimation of the effect of sub-transmission systems. Therefore, there is a need to reduce sub-transmission system for finding an effective location of shunt type FACTS devices such as SVC(Static Var Compensator), STATCOM(Static Synchronous Compesator), and so on.

  • PDF

A Study on the Torque Angle Compensator Design of an IPM Type PM Synchronous Motor

  • Byun, Young-Chul;Jeon, Hyuck-Soo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.139.1-139
    • /
    • 2001
  • Nowadays due to the remarkable advance of power electronics and micro controller, a Brushless AC servomotor which has the characteristics of the high inertia to torque ratio, the high power density, the maintenance free, and so on is being used widely in industrial robots, machine tools, and factory automation. In a conventional DC motor, the polarity commutation is performed of itself by mechanical brush and commutator, but the PM synchronous motor requires an electrical commutation according to the rotor position. Then for the maximum torque production PM synchronous motor has to be equipped with a controller which maintains the optimal phase angle between the stator field and the magnetic field ...

  • PDF

고효율 무정전전원장치

  • 대한전기협회
    • JOURNAL OF ELECTRICAL WORLD
    • /
    • s.291
    • /
    • pp.72-75
    • /
    • 2001
  • 정보네트워크산업이 급속히 발전, 보급되는 가운데 그 전원인 무정전전원장치(Uninterruptible Power Supply: UPS)에 대해서도 여러 가지 요구가 나오고 있다. 특히 최근에는 고신뢰성화$\cdot$소형화$\codt$저가격화에 더하여 러닝코스트 저감과 지구온난화 방지를 연결한 개념의 성에너지화를 목적으로 하는 전력변환효율의 향상에 대한 요구가 강해지고 있다. 이번에 이러한 요구에 응하기 위하여 미쓰비시전기는 상시상용 급전방식을 채용하여 HSS(High Speed Switch)회로와 쌍방향 컨버터회로를 개발하여, 고효율이며 급전신뢰성이 높은 MPC(Multiple Power Compensator)방식의 UPS를 개발하였다. 이에 의하여 전력변환효율을 90$\%$에서 98$\%(100kVA에서)로 대폭 개선함과 동시에 종래의 상용급전방식 UPS의 결점이었던 상용전원 이상시의 급전계통 전환시간을 부하기기에 영향을 미치지 않는 2밀리초까지 단축시켜 전환시에도 순간 단전됨이 없이 부하급전을 계속할 수 있도록 하였다. 또한 통상의 급전시에는 쌍방향 컨버터에 입력전류가 고조파보상기능을 갖게 하여 입력역률 0.99를 달성하였다.

  • PDF

Improvement of Torque Ripple Using Compensation for the Phase Delay of Winding Inductance on Brushless DC Motor (상 권선 인덕턴스의 위상지연 보상에 의한 브러시리스 직류 전동기의 토크 리플 개선)

  • 유시영;이두수
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.6 no.2
    • /
    • pp.180-190
    • /
    • 2001
  • In this paper, a method of reducing torque ripples caused by phase winding inductances in BLDCM(Brushless DC Motor) drives is presented. In order to compensate the inductive current delays, commutation angle is controlled by the value compensating angle varied in accordance with rotational speed. Using the microprocessor AVR 8515, the proposed compensator is implemented and experiments are done with a 4-pole 3-phase BLDCM. The results show the remarkable reduction of torque ripple at whole speed ranges.

  • PDF