• Title/Summary/Keyword: Power arc test

Search Result 121, Processing Time 0.026 seconds

Design of gate driver and test circuits for solid-state pulsed power modulator (반도체 소자기반 펄스 전원용 게이트 구동 및 시험회로 설계)

  • Gong, Ji-Woong;Ok, Seung-Bok;An, Suk-Ho;Jang, Sung-Roc;Ryoo, Hong-Je
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.230-231
    • /
    • 2012
  • This paper describes a gate driver that operates numerous semiconductor switch in the solide-state pulsed power modulator. the proposed gate driver is designed to receive both the isolated drive-power and the on/off pulse signals through the transformer. Moreover, the IGBT-switch can be quickly turned off by adding protection circuit. Therefore it protects the IGBT-switch from the arc condition that frequently occurs in high-voltage pulse application. To comprehend operating characteristic of each IGBT-switch in pulse output condition, the device consisting of a high efficiency soft-switching capacitor charger and two series stacking IGBT-switch is developed. Finally, the relability of the proposed gate driver and the device for its test are proved through PSpice simulation and experiments.

  • PDF

Development of the 120kV/70A High Voltage Switching Circuit with MOSFETs Operated by Simple Gate Drive Unit (120kV/70A MOSFETs Switch의 구동회로 개발)

  • 송인호;최창호
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.8 no.1
    • /
    • pp.24-29
    • /
    • 2003
  • A 120kV/70A high voltage switch has been installed at Korea Atomic Energy Research Institute(KAERI) in Taejon to supply power with Korea Superconducting Tokamak Advanced Research(KSTAR) Neutral Beam Injection(NBI) system. NBI system requires fast cutoff of the flower supply voltage for protection of the grid when arc detected and fast turn-on the voltage for sustaining the beam current. Therefore the high voltage switch and arc current detection circuit are important part of the NBI power supply. There are much need for high voltage solid state switches in NBI system and a broad area of applications. This switch consisted of 100 series connected MOSFETs and adopted the proposed simple and reliable gate drive circuit without bias supply. Various results taken during the commissioning phase with a 100kW resistive load and NBI source arc shown. This paper presents the detailed design of 120kV/70A high voltage MOSFETs switch and simple gate drive circuit. Problems with the high voltage switch and gate driver during thefabrication and test and solutions are also presented.

Analysis of Effects on the performance of ceramic metal halide lamp by the loss of elements that have been filled in arc tube

  • Jang, Hyeok-Jin;Yang, Jong-Gyeong;Lee, Jong-Chan;Kim, U-Yeong;Sin, Ik-Tae;Park, Dae-Hui
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.219-219
    • /
    • 2009
  • ceramic metal halide lamps are a subset of high intensity discharge lamps so named because of their high radiance These lamps weak ionized plasma in a fire-resisting but light transmissive wrapping by the corridor of current through atomic and molecular vapors. for commercial applications, For commercial applications, the conversion of electric power to light must occur with good efficiency and with sufficient spectral content throughout the visible (380-800 nm) to permit the light so generated to render colors comparable to natural sunlight. the purpose of this paper is to carry out a study on the variation of ageing time(2000 On/Off[hr]) on the performance of 150W CMH lamps. Experimental results show that the blackening by reacting W(tungsten)with I atomic has been created in the arc tube of an ageing lamp(2000 On/Off[hr]), the arc was unstable, and increased a lamp resistance made lamp voltage increases significantly. Also, Color temperature of the ageing lamp was moved by the losses of Ho with Dy atomics and by recombination of Na with I.

  • PDF

Development of Hard-wired Instrumentation and Control for the Neutral Beam Test Facility at KAERI

  • Jung Ki-Sok;Yoon Byung-Joo;Yoon Jae-Sung;Seo Min-Seok
    • Journal of Electrical Engineering and Technology
    • /
    • v.1 no.3
    • /
    • pp.359-365
    • /
    • 2006
  • Since the start of the KSTAR (Korea Superconducting Tokamak Advanced Research) project, Instrumentation and Control (I&C) of the Neutral Beam Test Facility (NB-TF) has been striving to answer diverse requests arising from various facets during the project's development and construction phases. Hard-wired electrical circuits have been designed, tested, fabricated, and finally installed to the relevant parts of the system. In relation to the vacuum system I&C, controlling functions for the rotary pumps, a Roots pump, two turbomolecular pumps, and four cryosorption pumps have been constructed. I&C for the ion source operation are the temperature and flow rate signal monitoring, Langmuir probe signal measurements, gradient grid current measurements, and arc detector circuit. For the huge power system to be monitored or safely operated, many temperature measurement functions have also been implemented for the beam line components like the neutralizer, bending magnet, ion dump, and calorimeter. Nearly all of the control and probe signals between the NB test stand and the control room were made to be transmitted through the optical cables. Failures of coolant flow or beam line vacuum pressure were made to be safely blocked from influencing the system by an appropriate interlock circuit that will shut down the extraction voltage application to the system or prevent damages to the vacuum components. Preliminary estimation of the beam power through the calorimetric measurement shows that 87.9% of the total power of the 60kV/18A beam with 200 seconds duration is absorbed by the calorimeter surface. Most of these I&C results would be highly appropriate for the construction of the main NBI facility for the KSTAR national fusion research project.

Design of Permanent Magnet Type Wind Power Generators for Cogging Torque Reduction with Optimum Pole Arc Pitch Ratio (코깅토크 저감을 위한 최적 극호비를 갖는 영구자석형 풍력발전기의 설계)

  • Jang, Seok-Myeong;Kim, Jin-Soon;Ko, Kyoung-Jin;Choi, Jang-Young;Yoon, Gi-Gab
    • Proceedings of the KIEE Conference
    • /
    • 2009.04b
    • /
    • pp.38-40
    • /
    • 2009
  • In order to achieve a gearless construction of the wind energy conversion system(WECS), a low-speed generator should be used. Of the various candidate machine types, radial-field, multi-pole, permanent magnet, synchronous machines may be used for low-speed applications. So, this paper deals with the design of direct-coupled, multi-pole radial field machines with permanent magnet(PM) excitation for wind power applications for cogging torque reduction through the determination of optimum pole arc/pitch ratio. On the basis of an equivalent magnetic circuit method(EMCM) and a space harmonic method(SHM), an initial design is performed considering restricted conditions. And then, a detailed design is made using a non-linear finite element analyses(FEA). Finally, test results concerning generating characteristics are given to confirm the validation of the design.

  • PDF

A Study on Energy Characteristics in Transient States of OF Cable Systems (OF 케이블 계통에서 과도상태시 에너지 특성 검토)

  • Jung, Chae-Kyun;Lee, Jong-Beom;Kang, Ji-Won;Lee, Dong-Il;Seo, Je-Ho
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.55 no.11
    • /
    • pp.468-475
    • /
    • 2006
  • This paper reviews the energy characteristics of oil filled cables in transient state such as grounding fault and lightning surge. Artificial grounding fault test was firstly performed in 2003 for the analysis of arc voltage and breakdown energy according to the fault current. In this paper, energy of OF cable is variously analysed at joint box based on the actual test. Then more various conditions such as installation types, section lengths and CCPU(Cable Covering Protection Unit) connection types are applied for the simulation using EMTP when the single line to ground fault and direct lightning stroke are occurred on actual underground power cable systems and combined power cable systems, respectively. Finally, the energy by the length of crossbonded lead and grounding lead as well as fault lasting time is also calculated using EMTP simulation.

Development of accelerated life test method for mechanical components using Weibull-IPL(Inverse Power Law) model (와이블-역승법을 이용한 기계류부품의 가속시험 방법 개발)

  • Lee, Geun-Ho;Kim, Hyoung-Eui;Kang, Bo-Sik
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.445-450
    • /
    • 2003
  • This study was performed 10 develop the accelerated life test method using Weibull-IPL(Inverse Power Law) model for mechanical components. Weibull-IPL model is concerned with determining the assurance life with confidence level and the accelerated life test time From the relation of weibull distribution factors and confidence limit, the testing times on the no number of failure acceptance criteria arc determined. The mechanical components generally represent wear and fatigue characteristics as a failure mode. IPL based on the cumulative damage theory is applied effectively the mechanical components to reduce the testing time and to achieve the accelerating test conditions. As the actual application example, accelerated life test method of agricultural tractor transmission was described. Life distribution of agricultural tractor transmission was supposed to follow Weibull distribution and life test time was calculated under the conditions of average life (MTBF) 3,000 hours and 90% confidence level for one test sample. According to IPL, because test time call be shorten in case increase test load test time could be reduced by 482 hours when we put the load 1.1 times of rated load than 0.73 times of rated load that is equivalent load calculated by load spectrum of the agricultural tractor. This time, acceleration coefficient was 11.7.

  • PDF

A Study on the Application of SAW Process for Thin Plate of 3.2 Thickness in Ship Structure (선체외판부 3.2T 박판에 대한 SAW 용접 적용에 관한 연구)

  • Oh, Chong-In;Yun, Jin-Oh;Lim, Dong-Young;Jeong, Sang-Hoon;Lee, Jeong-Soo
    • Proceedings of the KWS Conference
    • /
    • 2010.05a
    • /
    • pp.51-51
    • /
    • 2010
  • Recently just as in the automobile industry, shipbuilders also try to reduce material consumption and weight in order to keep operating costs as low as possible and improve the speed of production. Naturally industry is ever searching for welding techniques offering higher power, higher productivity and a better quality. Therefore it is important to have a details research based on the various welding process applied to steel and other materials, and to have the ability both to counsel interested companies and to evaluate the feasibility of implementation of this process. Submerged-arc welding (SAW) process is usually used about 20% of shipbuilding. Similar to gas metal arc welding(GMAW), SAW involves formation of an arc between a continuously-fed bare wire electrode and the work-piece. The process uses a flux to generate protective gases and slag, and to add alloying elements to the weld pool and a shielding gas is not required. Prior to welding, a thin layer of flux powder is placed on the work-piece surface. The arc moves along the joint line and as it does so, excess flux is recycled via a hopper. Remaining fused slag layers can be easily removed after welding. As the arc is completely covered by the flux layer, heat loss is extremely low. This produces a thermal efficiency as high as 60% (compared with 25% for manual metal arc). SAW process offers many advantages compared to conventional CO2 welding process. The main advantages of SAW are higher welding speed, facility of workers, less deformation and better than bead shape & strength of welded joint because there is no visible arc light, welding is spatter-free, fully-mechanized or automatic process, high travel speed, and depth of penetration and chemical composition of the deposited weld metal. However it is difficult to application of thin plate according to high heat input. So this paper has been focused on application of the field according to SAW process for thin plate in ship-structures. For this purpose, It has been decided to optimized welding condition by experiments, relationship between welding parameters and bead shapes, mechanical test such as tensile and bending. Also finite element(FE) based numerical comparison of thermal history and welding residual stress in A-grade 3.2 thickness steel of SAW been made in this study. From the result of this study, It makes substantial saving of time and manufacturing cost and raises the quality of product.

  • PDF

Assessment of Dynamic Stereoacuity of Adults in their 20s' with Howard-Dolman Test (하워드-돌먼 입체검사를 이용한 20대 성인의 동적 입체시 평가)

  • Shim, Hyun-Suk;Choi, Sun-Mi;Kim, Young-Cheong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.1
    • /
    • pp.61-66
    • /
    • 2015
  • Purpose: In this study, dynamic stereoacuity of 20s' adults were measured by using the Howard-Dolman test(H-D TEST, Bernell, U.S.A), and compared of male and female. And the correlation between dynamic stereoacuity and PD(pupillary distance), and between dynamic stereoacuity and anisometropia caused by difference in the spherical refractive power of the left and right eyes were analyzed. Methods: The mean age of $22.68{\pm}0.50$(20~29)years old, 20s' 63 adults (30 male, 33 female) were conducted for this experiments. After the full correction of subject's refractive error, dynamic stereoacuity was measured 5 times for 1 subject at 2.5 m distance using the H-D test. at 2.5 distance. Results: The mean of dynamic stereoacuity was $28.44{\pm}25.03$ sec of arc for total subjects, $28.23{\pm}23.34$ sec of arc for male, and $28.63{\pm}26.83$ sec of arc for female. In the dynamic stereoacuity classified by the range of inter-pupil distance (IPD), the dynamic stereoacuity was $33.87{\pm}18.53$ sec for the IPD being under 59.80 mm, $26.24{\pm}25.26$ sec of arc for 59.81~66.15 mm, $34.60{\pm}25.65$ sec of arc for over 66.15 mm. However, there were no significant differences between 3 groups (P=0.73, r=0.03). In dynamic stereoacuity classified by the refractive error difference between two eyes, dynamic stereoacuity was $26.81{\pm}24.86$ sec of arc for the under 1 D, $41.45{\pm}24.18$ sec of arc for over 1 D, and there was no significant difference between two groups (P=0.15, r=0.15). Conclusions: Dynamic stereacuity by the H-D test in 20s adults showed that there was no significant differences between male and female, and PD and anisometropia did not have a significant impact upon the dynamic stereoacuity.

Development of Single Phase Cabinet Panel with Electrical Safety Monitoring System by Mobile (모바일 이용 가능형 ESMS 기능의 단상 분전반 개발 연구)

  • Kim, Gi-Hyun;Lee, Sang-Ick;Shin, Seong-Su;Bae, Suk-Myong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.7
    • /
    • pp.92-96
    • /
    • 2011
  • In this paper, in order to reduce the electrical disaster such as electrical fire at traditional markets, we need to develop the ESMS(electrical safety monitoring system) which is able to monitor the power status of electrical equipments. Therefore, for solving the those problems, we developed the detection censor(ZCT, CT) and equipment of data analysis and transmission. The detection censor and equipment are able to monitor the electrical equipments condition(over current, leakage current, arc, etc.). We constructed Test-Bed for testing reliability of the ESMS and obtained certification. And we tested the over current, leakage current and arc under the normal condition.