• Title/Summary/Keyword: Power and phase detecting

Search Result 99, Processing Time 0.025 seconds

Sensorless Drive Method using Back EMF Analysis of Single Phase Switched Reluctance Motor (단상 SRM의 역기전력 분석을 통한 센서리스 구동기법)

  • Sun, Han-Geol;Shin, Duck-Shick;Yang, Hyong-Yeol;Lim, Young-Cheol
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.13 no.1
    • /
    • pp.33-40
    • /
    • 2008
  • This paper proposes a sensorless drive method that estimates the rotor position by analysing Back EMF of single-phase Switched Reluctance motor (SRM). The rotor position information is necessary required, because SRM's torque is generated by exciting a stator winding according to rotor position. In order to detect the position of the rotor, the various rotor position sensors have been used. However, most of the position sensors not only increase the construction cost and the volume of the motor but also decrease reliability of driving system with environment. This paper proposed the method using the Back EMF to solve such problems. When a rotor and stator are overlapped, the Back EMF is sharply changed. By detecting this point, the rotor position can be estimated. Thus SRM is driven by turn on and turn off switches at the proper position through speed calculation. The validity of proposed method is verified through simulation and experiment.

An Overcurrent Analysis in Neutral Line and Algorithm to Prevent Malfunction of Relay in Distributed Generations (분산전원 연계선로에서 지락고장시 중성선의 과전류 해석 및 보호계전기의 새로운 알고리즘)

  • Shin, Dong-Yeol;Kim, Dong-Myung;Cha, Han-Ju
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.10
    • /
    • pp.1916-1922
    • /
    • 2009
  • Introducing distributed generators(DGs) to utility distribution system can cause malfunction of relay on the grid when ground faults or severe load unbalances are occurred on the system. Because DGs interconnected to the grid can contribute fault currents and make bidirectional power flows on the system, fault currents from DGs can cause an interference of relay operation. A directional over current relay(DOCR) can determine the direction of power flow whether a fault occurs at the source side or load side through detecting the phases of voltage and current simultaneously. However, it is identified in this paper that the contributed fault current(Ifdg) from the ground source when was occurred to contribute single-line-to-ground(SLG) fault current, has various phases according to the distances from the ground source. It means that the directionality of Ifdg may not be determined by simply detecting the phases of voltage and current in some fault conditions. The magnitude of Ifdg can be estimated approximately as high as 3 times of a phase current and its maximum is up to 2,000 A depending on the capacity of generation facilities. In order to prevent malfunction of relay and damage of DG facilities from the contribution of ground fault currents, Ifdg should be limited within a proper range. Installation of neutral ground reactor (NGR) at a primary neutral of interconnection transformer was suggested in the paper. Capacity of the proposed NGR can be adjusted easily by controlling taps of the NGR. An algorithm for unidirectional relay was also proposed to prevent the malfunction of relay due to the fault current, Ifdg. By the algorithm, it is possible to determine the directionality of fault from measuring only the magnitude of fault current. It also implies that the directionality of fault can be detected by unidirectional relay without replacement of relay with the bidirectional relay.

A Study on the Phase Change Characteristics of Si-doped Ge2Sb2Te5 Thin Films for PRAM (PRAM을 위한 Si-doped Ge2Sb2Te5 박막의 상변화 특성 연구)

  • Baek, Seung-Cheol;Song, Ki-Ho;Lee, Hyun-Yong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.4
    • /
    • pp.261-266
    • /
    • 2010
  • In this paper, we report the changes of electrical, structural and optical characteristics in $Ge_2Sb_2Te_5$ thin films according to an increase of Si content. The Si-doped $Ge_2Sb_2Te_5$ thin films were prepared by rf-magnetron co-sputtering method. Isothermal annealing was carried out at $N_2$ atmosphere. The crystallization speed (v) of amorphous thin films was evaluated by detecting the reflection response signals using a nano-pulse scanner (wavelength = 658 nm) with illumination power of 1~17 mW and pulse duration of 10~460 ns. Structural phase changes were evaluated by XRD, and the optical transmittance was measured in the wavelength range of 300~3000 nm using UV-vis-NIR spectrophotometer. The sheet resistance (RS) of the thin films was measured using 4 point probe. Conclusivlely, the v-value decreased with an increase of Si content, while the RS-values of both crystalline and amorphous phases were increased. In particular, fcc-to-hexagonal transition was suppressed by the added Si atoms.

A Method of Knowledge Base Verification for Nuclear Power Plant Expert Systems Using Extended Petri Nets

  • Kwon, I.W.;Seong, P.H.
    • Nuclear Engineering and Technology
    • /
    • v.28 no.6
    • /
    • pp.522-531
    • /
    • 1996
  • The adoption of expert systems mainly as operator supporting systems is becoming increasingly popular as the control algorithms of system become more and more sophisticated and complicated. The verification phase of knowledge base is an important part for developing reliable expert systems, especially in nuclear industry. Although several strategies or tools have been developed to perform potential error checking, they often neglect the reliability of verification methods. Because a Petri net provides a uniform mathematical formalization of knowledge base, it has been employed for knowledge base verification. In this work, we devise and suggest an automated tool, called COKEP(Checker Of Knowledge base using Extended Petri net), for detecting incorrectness, inconsistency, and incompletensess in a knowledge base. The scope of the verification problem is expanded to chained errors, unlike previous studies that assume error incidence to be limited to rule pairs only. In addition, we consider certainty factor in checking, because most of knowledge bases have certainty factors.

  • PDF

Position Measurement Using Enclosed Signal Field with Pulse-Width-Modulated function

  • Ohyama, Shinji;Iizuka, Junya;Kobayashi, Akira
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.455-455
    • /
    • 2000
  • A novel pulse-width-modulated (PWM) function is introduced for precise position measurement in an enclosed signal field. An amplitude modulation was used to light the LEDs for the conventional study. However, the transform properties from the driving signal to the lighting intensities of the LEDs are non-linear, and accurate control of the lighting power was necessary. Therefore, a lighting function independent of these properties is desired. Well-known PWM functions are used to construct the enclosed signal field by simulation, and the precision of the phase detecting system is analyzed. A novel "axial symmetry PWM" function is found to be effective for orthogonal pahse detection.

  • PDF

A Study on the Detection of Asynchronous State of the Synchronous Generator

  • Choi, Hyung-Joo;Lee, Heung-Ho
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.2 no.4
    • /
    • pp.405-412
    • /
    • 2013
  • This paper includes new protection concepts and practices to avoid mechanical damage of three-phase transformer by asynchronous operation of synchronous generator. this failure is often caused just after synchronous generator was connected to the grid because of a malfunction of the controller or misconnections of the synchronous devices. The results of the studies on the analyzing the phenomenon of asynchronous operation experienced in Korea and rapidly detecting asynchronous state are descrived.

The Starting Characteristics Improvement of SPIM with One-Chip Microcontroller (One-Chip Microcontroller를 이용한 단상유도전동기의 기동특성개선)

  • Park, S.K.;Choi, N.I.;Baek, H.L.;Lim, Y.S.;Park, W.C.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07f
    • /
    • pp.1987-1989
    • /
    • 1998
  • A single phase induction motor is predominant in fractional horsepower rating and is widely used in home and industrial equipment. For example, these motors provide the motive power to washing machines, fans, refrigerators, etc. In this paper has presented the design and implementation of a microcontroller software - based self - starting SPIM. The control algorithm used in the experimentation employed simple control strategies which enabled a single chip programmable microcontroller to execute both the self - starting and self - detecting control of SPIM with relatively simplified hardware.

  • PDF

Switched Reluctance Motor Drives Using Interior Central Pole Search Coils (돌극관통 서치코일을 이용한 스위치드 릴럭턴스 모터의 회전자 위치검출 및 구동)

  • Shin D. S.;Yang H. Y.;Lim Y. C.
    • Proceedings of the KIPE Conference
    • /
    • 2004.07a
    • /
    • pp.196-200
    • /
    • 2004
  • This paper presents a new method of detecting rotor position in Toroidal Switched Reluctance Motor(TSRM). In this paper, low cost and robust characteristics of rotor position detection method are focused in order to compensate for disadvantage of general sensors. Search coils wound through the hole of the stator poles are used for detection of the rotor position in TSRM. Rotor position detection is achieved through electromotive force patterns induced by time-varying flux linkage in the search coils and then adequate phase is excited for drive. The initial rotor position estimation method is also described. The validity of the method is verified by experimental results.

  • PDF

PWM Converter Control considering time varying source voltage (Time Varying 전원 전압을 고려한 PWM 컨버터 제어)

  • 주인원;임선경;남광희
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.692-695
    • /
    • 1999
  • A new control scheme is proposed suitable for the three phase PWM converter having abrupt load variation such as a crane. In the converter used in a crane, the peak value of source voltage varies instantaneously due to the abrupt load variations. Such a voltage variation degrades the performance of DC-link control of PWM converter. To overcome this problem, load variations should be detected and compensated properly. We propose a new method for detecting and compensating the load variations without the additional hardware. With the proposed scheme, load variations are detected by estimating the current of DC-link capacitor. The estimated current information is feedbacked to a current controller to improve the performance. Additionally, the variation of source voltage is compensated using feedforward controller. The performance of the proposed scheme has been verified through simulations.

  • PDF

A Study on the Sensorless Drive of BLDCM through Initial Rotor Position Detecting (초기 회전자 위치 검출을 통한 BLDCM의 센서리스 구동에 관한 연구)

  • Jang Hoon;Bae Jong-Pyo;Kim Jong-Sun;Yoo Ji-Yoon;Yang Ha-Yeong;Yeo Hyeong-Gee
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.129-132
    • /
    • 2002
  • The first purpose of this paper is to develop the sensorless drive at adjustable speed without any mechanical position or speed sensor. For this, this research analyzes terminal voltage, finds the rotor position information and makes the source of commutations of phase current. The second purpose is to propose the sensing method of initial rotor position without instantaneous rotating. Experimental results show the validity and practical use of the proposed sensing method.

  • PDF