• Title/Summary/Keyword: Power absorbtion

Search Result 7, Processing Time 0.019 seconds

A Study on the Development of a Resonator to Reduce the Ship Engine Room Noise (선박기관실의 소음 저감을 위한 차폐공명기의 개발에 관한 연구)

  • Yu, Y.H.
    • Journal of Power System Engineering
    • /
    • v.11 no.4
    • /
    • pp.72-77
    • /
    • 2007
  • It is known that elimination of ship engine room noise is impossible thing, so the working environment in the engine room is getting worse because ships are recently built with huge engines to take higher sailing power. In the yacht and cruise yacht, the engine room noise is more serious because they have bigger engines relative to their hull sizes. The noise generated from the main engine makes the employee to hearing loss and the transmitted noise make the uncomfortable conditions in the cabins of ship. The noise generated by ship engine must be attenuate for the employee and passenger. In yacht and cruise yacht, the noise levels in cabines are the most important criterions to the value of commodities. In this study, the noise absorbtion barrier which have resonators is experimentally studied by the 1/3 octave band noise elimination rates(%).

  • PDF

The evaluation of Sound Power Level and development of index for Sound Quality of Vacuum Cleaner according to performances of Sound Absorbtion Materials (흡음재 성능에 따른 진공청소기의 음향파워 평가 및 음질인덱스 개발)

  • Kwon, Hyuk-Je;Lee, Sang-Kwon;Gu, Jin-Hoi;Lee, Hyun-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.112-120
    • /
    • 2008
  • Today, the use of a vacuum cleaner gave us the higher quality of life than past time, but sometimes made us w1comfortable in the house because of the specific noise that is annoying. So we need to study how sound absorbtion materials affect sound power level and sound quality with sound metrics. In this paper, we will measure and calculate sound power level for vacuum cleaner and analyze characteristics of the noise for 10 Signals according to materials positioned in vacuum cleaner. The multiple regression analysis can estimate the nonlinear characteristics of relation between subjective evaluation and sound metrics. So we will develop sound quality index for vacuum sound.

  • PDF

An Experimental Study on Water Absorbtion Characteristics of Generator Stator Bar Insulation by Cooling Water Temperature in 500MW Capacity Power Plant (500MW급 화력 발전기 냉각수 온도에 따른 고정자 권선 절연재의 흡습 특성에 관한 실험적 연구)

  • Bae, Yong-Chae;Kim, Hee-Soo;Lee, Doo-Young;Lee, Wook-Ryun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.8
    • /
    • pp.1392-1397
    • /
    • 2008
  • The mechanical integrity of generator stator windings is one of the critical point because the electric power is generated and conducted to power system through these windings. De-mineralized water is used to cool stator bars during the normal operation of generator in large power plants because the water cooled method has highest cooling efficient. Water absorption of bar insulation is progressed by several causes such as generation of water leak path by corrosion, delamination of insulation by vibration, and inadequate water treatment, etc.. Reliable water absorption diagnostics of generator stator bar is important to ensure the availability of power plant and to reduce maintenance cost by generator accident. It is described that the water absorption characteristics for generator stator bar insulation used in 500MW capacity standard fossil power plant by cooling water temperature. It is verified that the management of stator cooling water temperature is one of the important factors to decrease water absorption rate of generator stator bars.

A Study on the Development of the Acoustic Absorption Well of the Cruise Yacht (크루즈요트의 기관실 소음 차단용 차음벽 개발에 관한 연구)

  • Yu, Young-Hun;Yi, Jong-Keun
    • Proceedings of KOSOMES biannual meeting
    • /
    • 2007.05a
    • /
    • pp.109-113
    • /
    • 2007
  • Yacht have an high powered main engine relatively light hull, so the noise generated from the engine have a bad influence upon the crew and passenger. Recently, cruise yacht is made an attempt by domestic production skill, however the insulation skill of the noise made by the main engine is not satisfy the real purchasing power of the buyer. Like this, yacht cabin's noise level is becoming the barometer to decide the purchase. the method to insufficient. However, if we use the skill of the monitoring equipment and the genetic algorithm system, the circumference of the main engine can be enclosed by an high quality absorbtion wall and the noise levels of the cabins are improved. In this study, the sound absorbtion barrier is experimentally researched by change the volume and the length of the neck for the Helmholtz resonator as the resonator can absorb the noise effectively.

  • PDF

Extraction of Wave Energy Using the Coupled Heaving Motion of a Circular Cylinder and Linear Electric Generator (원기둥과 선형발전기의 연성 수직운동을 이용한 파 에너지 추출)

  • Cho, Il-Hyoung;Kweon, Hyuck-Min
    • Journal of Ocean Engineering and Technology
    • /
    • v.25 no.6
    • /
    • pp.9-16
    • /
    • 2011
  • The feasibility of wave energy extraction from a heaving truncated cylinder and the corresponding response of the linear electric generator (LEG) composed of spring, magnet, and coil has been investigated in the frame of three-dimensional linear potential theory. The heaving motion of a circular cylinder is calculated by means of the matched eigenfunction expansion method. Further, the analytical results are validated by numerical results using the ANSYS AQWA commercial code. By the action of a heaving circular cylinder, the magnet suspended by a spring can slide vertically inside the heaving cylinder. The mechanical power is extracted from the magnet motion relative to the coil/stator which is attached to the cylinder. The coupled ODE of a heaving cylinder and LEG system in waves is derived to obtain the magnet motion relative to a cylinder. To maximize the relative motion of the magnet, both the buoy draft and the LEG system parameters (spring stiffness, damping) should be selected properly for generating the double resonance considering the peak frequency of the target spectrum.

A Study on the Analysis of Damage Cause for MOF Installed in 22.9 kV Power Receiving System (22.9 kV 수전설비 시스템에 설치된 계기용변성기의 소손원인 판정에 관한 연구)

  • Kim Hyang-Kon;Shong Kil-Mok;Kim Dong-Ook;Choi Chung-Seog
    • Fire Science and Engineering
    • /
    • v.19 no.1 s.57
    • /
    • pp.93-98
    • /
    • 2005
  • The purpose of this paper is to judge the damage cause of instrument transformer(MOF; Metering Out Fit) installed in 22.9kV power receiving system. In the three-dimensional analysis of the restored MOF, the damage pattern progressed from inside to outside, there was no damaged part in the upside. The resistance of the carbonized middle part is roughly $100\kappa\Omega$ and the exothermic temperature at inside is presumed as about $300\~800^{\circ}C$ in the result of metallurgical structure analysis. The structure and the composition rate on metal surface by SEM is similar. In the result of FT-IR analysis, we can observe the absorbtion peak at $1500cm^{-1}\;and\;1730 cm^{-1}$ is small. The high exothermic peak showed at the center part of the coil in the result of DTA.

A Study on the CO2 Removal Efficiency with Aqueous MEA and Blended Solutions in a Vortex Tube Type Absorber (Vortex Tube 형 흡수장치에서 MEA와 혼합흡수용액을 이용한 CO2 제거 효율 고찰)

  • Ryu, Woo-Jung;Han, Keun-Hee;Choi, Won-Kil;Lee, Jong-Sub;Park, So-Jin
    • Korean Chemical Engineering Research
    • /
    • v.47 no.6
    • /
    • pp.795-800
    • /
    • 2009
  • In this study, the $CO_2$ removal characteristics of the Vortex tube type absorbtion apparatus were investigated to enhance the compactness of $CO_2$ absorption process and to reduce the amount of absorbing solution of the $CO_2$ separation process. The Vortex tube with the diameter of 17 mm and the length of 250mm was introduced in the experimental apparatus to treat $20Nm^3/hr$ of $CO_2$ containing flue gas. The flue gases for experiments containing 11~13 vol% of $CO_2$ were supplied from the coal-firing CFBC power plant with 12 ton/hr of steam producing capacity. The mixed solutions of 20 wt% of MEA as base solution with the adding solutions like HMDA, AMP and KOH were used as absorbents. The experiments were executed under the various conditions like the absorbing solution concentrations in the range of 20 to 50 wt%, the flow rate of $CO_2$ containing flue gases in the range of 6 to $15Nm^3/hr$ and the flow rate of absorbing solution in the range of 1.0 to 3.0 l/min. As a results, the $CO_2$ removal efficiency of mixed absorbent of 20 wt% of MEA with HMDA was remarkable. From this study, we concluded that the efficient separation of $CO_2$ from flue gases using the features of the Vortex tube type absorbing unit for gas/liquid contact and the separation of gas/liquid be possible. But more works are needed to increase the $CO_2$ removal efficiency of Vortex tube process.