• Title/Summary/Keyword: Power Window

Search Result 459, Processing Time 0.031 seconds

The driving system design of walking robot which uses the automotive window motor (자동차용 윈도우 모터를 이용한 보행로봇 구동부 설계)

  • YOUM, K.W.;HAM, S.H.;OH, S.H.
    • Journal of the Korean Society of Mechanical Technology
    • /
    • v.13 no.4
    • /
    • pp.137-141
    • /
    • 2011
  • Driving mechanism, the central part of a robot, was designed in this study. Power for the motive drive was acquired by directly connecting the motor shaft in worm shape of the low-end DC motor, car window motor, to a decelerator. The decelerator consists of a worm gear to receive power from the motor shaft, a pinion gear to be connected in line with the worm gear, and an output shaft to be engaged to the pinion gear. Motion driving is achieved by the power from the motor shaft with the designed gears, transferred to the deceleration mechanism and to the output gear.

A Study on the Operating Characteristics by Heat Flow Analysis of HYPER Beam Window (HYPER 빔창의 열수력 해석에 의한 운전특성에 관한 연구)

  • Song, Min-Geun;Choi, Jin-Ho;Ju, Eun-Sun;Song, Tae-Young
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.915-920
    • /
    • 2001
  • A spent fuel problem has prevented the nuclear power from claiming to be a completely clean energy source. The nuclear transmutation technology to incinerate the long lived radioactive nuclides and produce energy during the incineration process is believed to be one or the best solutions. HYPER(Hybrid Power Extraction Reactor) is the accelerator driven transmutation system which is being developed by KAERI(Korea Atomic Energy Research Institute). Some major feature of HYPER have been developed and employed. On-power fueling concepts are employed to keep system power constant with minimum variation of accelerator power. A hollow cylinder-type metal fuel is designed for the on-line refueling concept. Lead-bismuth(Pb-Bi) is adopted as a coolant and Spallation target material. HYPER is a subcritical reactor which needs an external neutron source. 1GeV proton beam is irradiated to Lead-bismuth(Pb-Bi) target inside HYPER, and spallation neutrons are produced. When proton beams are irradiated, much heat is also deposited in the Pb-Bi target and beam window which separates Pb-Bi and accelerator vacuum. Therfore, an effective cooling is needed for HYPER target. In this paper, we performed the thermal-hydraulic analysis of HYPER target using FLUENT code, and also calculated thermal and mechanical stress of the beam window using ANSYS code.

  • PDF

Wigner-Ville Distribution Applying the Rotating Window and Its Characteristics (회전 창문함수를 적용한 위그너-빌 분포함수와 그 특성)

  • 박연규;김양한
    • Journal of KSNVE
    • /
    • v.7 no.5
    • /
    • pp.747-756
    • /
    • 1997
  • Wigner-Ville distribution which is a time-frequency analysis has a fatal drawback, when the signal has multiple components. This is the cross-talk and often causes a neagative value in the distribution. Wingner-Ville distriution is an expression of power, therefore the cross-talk must be avoided. Smoothing the Wigner-Ville distribution by convoluting it with a window, is most commonly used to reduce the cross-talk. There can be infinite number of distributions depending on the windows. But, the smoothing reduces resolution in time-frequency plane; this motives to design a more effective window in reducing cross-talk while remaining resolution. The domain in which the cross-talk and legitimate components can be easily distinguished, is the ambiguity function. In the ambiguity function domain, the legitimate components appear as linear lines passing through the orgine. But, the cross-talk is widely distributes in the ambiguity function plane. Based on the relative distributions of cross-talk and legitimate components, rotating window can be designed to minimize cross-talk. Applying the rotating window to the ambiguity function corresponds to smoothing the Wigner-Ville distribution. Therefore, the effects of rotating window is estimated in terms of the bias error due to smooting the Wigner-Ville distribution. By applying the rotating window, not only the Wigner-Ville distribution but also its properties are changed. The properties of the new distribution are checked, in order to complete analyzing the rotating window.

  • PDF

Performance Comparisons on the Strategies of Sleep Window Size Adjustment for Power Saving in IEEE 802.16e (IEEE 802.16e에서 전력 절약을 위한 수면 윈도우 크기 조정 방법들의 성능 비교)

  • Son, Dae-Hong;Roh, Byeong-Hee
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.32 no.11A
    • /
    • pp.1113-1119
    • /
    • 2007
  • In this paper, first, we proposed various possible candidate schemes for determining initial sleep window size and varying sleep window size in sleep mode for power saving class I of IEEE 802.16e. Then, we analyzed and compared the power saving performances of those schemes. The schemes used for the comparisons are EICV of IEEE 802.16e, and other comparable schemes such as EIED, EILD, LIED and LILD. Experimental results show that LILD and EIED outperform other comparable schemes. Especially, EIED shows the better performances for the case of high traffic intensity environments, while LILD does for the low traffic intensity case.

CMI Tolerant Readout IC for Two-Electrode ECG Recording (공통-모드 간섭 (CMI)에 강인한 2-전극 기반 심전도 계측 회로)

  • Sanggyun Kang;Kyeongsik Nam;Hyoungho Ko
    • Journal of Sensor Science and Technology
    • /
    • v.32 no.6
    • /
    • pp.432-440
    • /
    • 2023
  • This study introduces an efficient readout circuit designed for two-electrode electrocardiogram (ECG) recording, characterized by its low-noise and low-power consumption attributes. Unlike its three-electrode counterpart, the two-electrode ECG is susceptible to common-mode interference (CMI), causing signal distortion. To counter this, the proposed circuit integrates a common-mode charge pump (CMCP) with a window comparator, allowing for a CMI tolerance of up to 20 VPP. The CMCP design prevents the activation of electrostatic discharge (ESD) diodes and becomes operational only when CMI surpasses the predetermined range set by the window comparator. This ensures power efficiency and minimizes intermodulation distortion (IMD) arising from switching noise. To maintain ECG signal accuracy, the circuit employs a chopper-stabilized instrumentation amplifier (IA) for low-noise attributes, and to achieve high input impedance, it incorporates a floating high-pass filter (HPF) and a current-feedback instrumentation amplifier (CFIA). This comprehensive design integrates various components, including a QRS peak detector and serial peripheral interface (SPI), into a single 0.18-㎛ CMOS chip occupying 0.54 mm2. Experimental evaluations showed a 0.59 µVRMS noise level within a 1-100 Hz bandwidth and a power draw of 23.83 µW at 1.8 V.

Active Window system based on Finite Thickness Window Model (유한 두께 창문 모델을 적용한 능동 소음제어 창문)

  • Kwon, Byoung-Ho;Park, Young-Jin
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.763-768
    • /
    • 2012
  • Active window system which can reduce the environmental noises, such as traffic noise and construction noise, from an open window into a room was proposed in the previous works. The key idea of the proposed active window system was that the control sources are approximately collocated with the primary noise source in terms of the acoustic power for global noise reduction throughout the interior room. Moreover, because it is important not to intrude into the living space in the building environment, no error sensors were used and an open-loop control method using control sources at the window frame and the reference sensors outside the room was used for the proposed system. The open-loop control gain was calculated by the interior room model assumed as the semi-infinite space, and the interior sound field was estimated by Rayleigh integral equation under the baffled window model assumption. However, windows with a finite thickness should were considered for the calculation of the open-loop control gain of the active window system since these are representative of most window cases. Therefore, the finite thickness window model based on the Sgard's model was derived and the open-loop control gain using the interior sound field estimated by that model was calculated for active window system. To compare the performance of these two models, a scale-model experiment was performed in an anechoic chamber according to noise source directions. Experimental results showed that the performance for the thickness window model is better than the baffled window model as the angle with respect to the perpendicular direction is larger.

  • PDF

The Effect of Shielding Gas Composition on High Power Laser Welding Characteristics (보호가스 종류에 따른 고출력 레이저 용접특성)

  • Ahn, Young-Nam;Kim, Cheolhee
    • Journal of Welding and Joining
    • /
    • v.33 no.4
    • /
    • pp.17-23
    • /
    • 2015
  • Laser-gas metal arc hybrid welding has been considered as an alternative process of gas metal arc welding for offshore pipe laying. Fiber delivered high power lasers which enable deep penetration welding were recently developed but high power welding characteristics were not fully understood yet. In this study, the influence of shielding gas composition on welding phenomena in high power laser welding was investigated. Bead shapes, melt ejection and dropping were observed after autogenous laser welding with 100% Ar, Ar-20% $CO_2$, Ar-50% $CO_2$, and 100% $CO_2$ shielding gas. Process parameter window was widest with Ar-50% $CO_2$ shielding gas and the penetration was deepest with 100% $CO_2$ shielding gas. The melt dropping was not observed when Ar-50% $CO_2$ or 100% $CO_2$ shielding gas was supplied.

A Simulation Study on the Performance of the RAW in IEEE 802.11ah WLANs (IEEE 802.11ah WLAN환경에서 모의실험을 통한 RAW 성능 분석)

  • Jin, Sunggeun
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.20 no.2
    • /
    • pp.39-44
    • /
    • 2015
  • Restricted Access Window (RAW) has been designed to improve power saving efficiency by reducing collisions of contending stations in the IEEE 802.11ah Wireless Local Area Networks (WLANs). We conduct simulations in order to observe the stations' operations influencing the lengths of the Restricted Access Window (RAW). From the observation, we consider how to adjust the stations' operations for proper RAW managements.

Constructed Sound Field of an Induction Motor Using Cylindrical Acoustic Holography (원통형 음향 홀로그래피를 이용하여 구성한 유도전동기의 방사 음장)

  • 김시문;김양한
    • Journal of KSNVE
    • /
    • v.7 no.6
    • /
    • pp.919-929
    • /
    • 1997
  • Induction motors are used in many areas to transform electrical energy to mechanical energy. In the design of an induction motor, not only energy efficiency but also noise becomes an important factor. To effectively address the noise problem, it will be convenient if one can see where and how noise is generated and propagated. In this study sound radiation by an induction motor is visualized using cylindrical acoustic holography. To minimize the bias error by window effect Minimum Error Window(MEW) is used. Its performance is verified by numerical simulations. Based on these theoretical understanding, sound pressure measurement with an induction motor are performed. Not only sound radiation are visualized but sound pressure level and sound power level are also estimated. Results show that the main source is located at nearly bottom part of the motor and the total sound pressure level is 49dB, which satisfies the guideline value suggested by the KS C 4202.

  • PDF

Nonparmetric Method for Identifying Effective and Safe Doses using Placement (유효하고 안전한 용량 결정에 위치를 이용한 비모수적 방법)

  • Kim, Sunhye;Kim, Dongjae
    • The Korean Journal of Applied Statistics
    • /
    • v.27 no.7
    • /
    • pp.1197-1205
    • /
    • 2014
  • Typical clinical dose development studies consist of the comparison of several doses of a drug with a placebo. The primary interest is to find therapeutic window that satisfying both efficacy and safety. In this paper, we propose nonparametric method for identifying effective and safe doses in linear placement using score function. The Monte Carlo simulation is adapted to estimate the power and the family-wise error rate(FWE) of proposed procedure are compared with previous methods.