• Title/Summary/Keyword: Power Transmission Systems

Search Result 1,404, Processing Time 0.035 seconds

Auto-Configuration Downlink Transmission Power Approach For Femtocell Base Station

  • Alotaibi, Sultan
    • International Journal of Computer Science & Network Security
    • /
    • v.22 no.4
    • /
    • pp.223-228
    • /
    • 2022
  • Femtocells are being incorporated into heterogeneous networks in order to increase the network capacity. However, intensive deployment of femtocells results in undesired interference, which lowers the system's performance. Controlling the femtocell transmission power is one of of the aspects that can be addressed in order to mitigate the negative effects of the interference. It may also be utilized to facilitate the auto-configuration of the network's conductance, if necessary. This paper proposes the use of an auto-configuration technique for transmission power. The suggested technique is based on the transmission power of macrocells and the coverage provided by femtocells. The simulation findings show that the network's capacity has increased, and the amount of interference has decreased.

Stabilization of Power Systems with a Sliding Control Using Fuzzy Estimation of Bounding Function (전력계통 안정화를 위한 퍼지 유계함수 추정을 이용한 슬라이딩 제어)

  • Park, Young-Hwan;Park, Gwi-Tae
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.875-879
    • /
    • 1998
  • A fault on the transmission line results in the variation of reactance and parametric uncertainties in the power system dynamics. In this case, we need a robust control to cope with these uncertainties. A sliding mode control, a sort of robust control, is known to be robust to parametric or state-dependent uncertainties if the bounding function of uncertain terms is determined a priori. However, in general, we can not readily determine the bounding function for the complex systems. Hence, in this paper we introduce a fuzzy system which can estimate the bounding function in relatively simple way. By the use of the proposed fuzzy system, determination of bounding function is made easier. We applied the proposed scheme to the stabilization of power system under the sudden fault on the transmission lines. The simulation result verifies the effectiveness of the scheme.

  • PDF

A Probabilistic Reliability Assessment of KEPCO Future System with Applied HTS-FCL (초전도 한류기를 적용한 한전미래계통의 확률론적 신뢰도 평가)

  • Kwon, Jung-Ji;Lee, Seung-Ryul;Yoon, Jae-Young;Choi, Jae-Seok
    • Progress in Superconductivity and Cryogenics
    • /
    • v.10 no.3
    • /
    • pp.19-22
    • /
    • 2008
  • The power systems should be improved to reduce the number of black-out events occurring throughout the world. Quantitative evaluation of composite power system reliability is very important in a competitive electricity environment. The reason is that the successful operation of electric power systems under a deregulated electricity market depends on transmission system reliability management. This paper presents sensitivity analysis of probabilistic reliability indices of Korea power systems with checking application of HTS-FCL.

Power Stage Design for a Surface Wireless Power Transmission System using a Coupled Electric Field (전계결합을 이용한 면대면 무선 에너지 전송회로 개발)

  • Choi, Sung-Jin;Kim, Se-Yeong;Choi, Byung-Woo
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.20 no.2
    • /
    • pp.143-148
    • /
    • 2014
  • Conventional wireless power transfer methods based on coupled magnetic fields need a complex winding structure on the surface of the energy transfer and shows poor efficiency near metal objects due to the eddy current effect. In this study, to mitigate these problems, we investigate an electric field-coupled power transmission system, which is less prone to metal object problems and EMI. Because of the fundamental physical limit in the size of link capacitances, a half-bridge converter with an impedance matching transformer is proposed and the design procedure is derived to provide a soft-switching scheme. Hardware implementation shows that the proposed scheme with a pair of 10cm by 10cm copper plate can power a 1.4W USB FAN in a separation of 0.2mm by using insulating paper when driven by 227 kHz gate pulse.

The Influence on GAS pipelines Buried in nearby Tower of 345kV Transmission Line (345kV 송전선로 철탑이 인근에 매설된 가스배관에 미치는 영향)

  • Lee, H.G.;Ha, T.H.;Bae, J.H.;Kim, D.K.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.349-351
    • /
    • 2001
  • Because of the continuous growth of energy consumption and also the tendency to site power lines and pipelines along the same route, the close proximity of power lines and buried metallic pipelines has become more and more frequent. Therefore there has been and still is a growing concern about possible hazards resulting from the influence of power lines on metallic pipelines. When a ground fault occurs in an electrical installation the current flowing through the earthing electrode produces a potential rise of the electrode and of the neighbouring soil with regard to a remote earth. This paper analyzes the effects of ground faults when the current will flow into the soil from the foot of 345kV transmission line tower.

  • PDF

A Study on the Operation Strategies of Multi-Infeed HVDC System in Jeju Island Power System (제주지역 계통특성을 고려한 다기(Multi-Infeed) HVDC 시스템 운전 방안에 관한 연구)

  • Lee, Seung-Yeup;Yoon, Min-Han
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.12
    • /
    • pp.1675-1681
    • /
    • 2017
  • As recently the demand on electric power has been increasing, the requirement of power supply reliability has been increased. Accordingly, the number of HVDC transmission systems in the world has been steadily increased, which have been installed in the power system to transmit a large capacity power to the long distant and interconnect the power grid between different countries. etc. #1 HVDC Transmission System was installed between Haenam and Jeju island in 1998, which is the first HVDC system furnished in korea. and has been operated until now. Before #1 HVDC Transmission System being installed, the power system of the Jeju Island is a isolated power system from that of Korea mainland. After the construction of #1 HVDC the system has made the Jeju power system more reliable and also been able to supply the mainland power, which was cheaper than that of Jeju island, to Jeju island. The construction of additional HVDC transmission system between mainland and the Jeju Island has been currently underway to cope with recent changes of the power market of the Jeju island, for examples the increase of power demand and the capacity of wind power generation. etc. #2 HVDC Transmission System construction was completed in 2012. #3 HVDC Transmission System will be also installed according to the plan. If all goes as planned, the Jeju power system will be operated with Multi-Infeed HVDC system connected to mainland power system. So the additional studies are needed in order to maintain the stability of the Jeju power system and get the efficiency of the Multi-Infeed HVDC system. Therefore, in this paper, the optimal operation strategies of the Multi-Infeed HVDC system between the mainland of Korea and the Jeju are suggested to ensure the stability of the power system in Jeju Island when the Multi-Infeed HVDC system is operated between two power system.

Modelling and Performance Analysis of UPFC Using EMTP/ATPDraw (EMTP/ATPDraw를 이용한 UPFC구현 및 동작 분석)

  • Jang, Won-Hyeok;Lee, You-Jin;Rhee, Sang-Bong
    • Proceedings of the KIEE Conference
    • /
    • 2008.11a
    • /
    • pp.217-219
    • /
    • 2008
  • Among the Flexible AC Transmission Systems (FACTS) devices, Unified Power Flow Controller (UPFC) is considered as the most powerful and versatile one as it provides simultaneous, real time control of the transmission parameters, voltages, impedances, and phase angles which determine the power flow in AC transmission systems. This paper presents modelling of UPFC and describes its characteristics. The UPFC implemented in this paper is based on Sinusoidal Pulse Width Modulation (SPWM) and Electro-Magnetic Transients Program (EMTP)/ATPDraw is used to model and analyze it. The simulation results confirm advantages of UPFC in operational performance with respect to the steady state Power flow regulation and the transient stability control.

  • PDF

A Study on the Digital Distance Relaying Algorithm Using Wavelet Transform in Combined Transmission Line with Underground Power Gables (웨이브렛 변환을 이용한 혼합송전계통에서의 디지털 거리계전 알고리즘에 관한 연구)

  • Jung, Che-Kyun;Hong, Dong-Suk;Lee, Jong-Beom
    • Proceedings of the KIEE Conference
    • /
    • 2001.11b
    • /
    • pp.383-386
    • /
    • 2001
  • Distance relay is tripped by the line impedance calculated at the relay point. Accordingly the accurate operation depends on the precise calculation of line impedance. Impedance can be accurately calculated in case of overhead line. However, in case of power cables or combined transmission lines, impedance can not be accurately calculated because cable systems have the sheath, grounding wires, and cable cover protection units (CCPUs). There are also several grounding systems in cable systems. Therefore, if there is a fault in cable system, these terms will severely be caused much error to calculation of impedance. Accordingly the proper compensation should be developed for the correct operation of the distance relay. This paper presents the distance calculating algorithm in combined transmission line with power cable using wavelet transform. In order to achieve such purpose, judgement method to discriminate the fault section in both sections was proposed using db1 coefficient summation. And also, error compensation factor was proposed for correct calculation of impedance in power cable.

  • PDF

Optimal Operation by integrating Sihwa Power into NamSihwa Systems (시화조력발전 연계에 의한 남시화 계통의 최적 운영 방안)

  • Kim, Kyu-Ho;Song, Kyung-Bin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.5
    • /
    • pp.120-126
    • /
    • 2009
  • This paper presents an optimal operating scheme by integrating Sihwa tidal power into NamSihwa systems. For optimal operation of NamSihwa systems, the sea levels of 1 minute interval using cubic interpolation based on the forecasted levels of high and low water are calculated. Especially, it is compared by three schemes to purchase total power from transmission system to purchase total power from tidal power system in time period that can generate tidal power and to purchase total power by comparing purchase costs from transmission system and tidal power system. The scheme may contribute to energy save in Korea that natural resources are lacking.

Investigation of Superconducting Fault Current Limiter effect for a 345kV transmission line system fault through the EMTP simulation (EMTP를 이용한 345kV급 송전계통 사고시 초전도한류기가 미치는 영향 검토)

  • Park, Soo-Man;Kim, Jae-Chul;Moon, Jong-Fil;Hong, Won-Pyo;Lee, Seung-Hark
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.148-150
    • /
    • 2002
  • Recently the demand for electrical power is significantly increased due to the life improvement of customers. Correspond to the result, the transmission capacity is larger, also the fault current is significantly larger. Within the methods of limiting this fault current, the methods of using the fault current limiter is on the rise. If the Superconducting Fault Current Limiter(SFCL) is applied, then the power delivery loss doesn't exist between the plural power systems, also the fault current can be reduce. But for applying the real system, it needs to investigate the effect of SFCL before appling to real power systems. Consequently, the fault of transmission with SFCL was simulated using EMTP. It was investigated to the effect of SFCL at the 345[kV] transmission fault according to compare with the case of appling SFCL and removing SFCL.

  • PDF