• 제목/요약/키워드: Power Transmission Systems

검색결과 1,404건 처리시간 0.029초

FACTS 기기를 이용한 전력시스템의 안전도 향상 (The Enhancement of Power System Security Using flexible AC Transmission Systems (FACTS))

  • 송성환;임정욱;문승일
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권3호
    • /
    • pp.165-172
    • /
    • 2003
  • This paper presents an operation scheme to enhance the power system security by applying FACTS on Power systems. Three main generic types of FACTS devices are suggested an illustrated. Flow congestions over lines have been solved by controlling active power of series-compensated FACTS devices and low voltages at buses have been solved by controlling reactive power of shunt-compensated FACTS devices. Especially, Especially, UPFC has been applied in both line congestion and low voltages. Two kinds of indices which indicate the power system security level related to line flow and bus voltage are utilized in this paper. They have been minimized to enhance the power system security level through the iterative method and the sensitivity vector of security index is derived to determine the direction to minimum. The proposed algorithm has been tested on the IEEE 57-bus system with FACTS devices in a normal condition and a line-faulted contingency.

과도 안정도를 고려한 국내 송전선로 재폐로 방식 평가 (An Evaluation of Reclosing Schemes in Korean Transmission Systems Considering Transient Stability)

  • 오윤식;권기현;박지경;조규정;손승현;김철환;김완종
    • 전기학회논문지
    • /
    • 제62권6호
    • /
    • pp.731-736
    • /
    • 2013
  • Most of faults occurring in transmission lines are transient faults. For such faults, automatic reclosing is economic and effective method to improve the reliability and transient stability of power system. Many countries apply various reclosing schemes considering issues of their own systems such as transient stability, rate of success. Currently, different reclosing schemes are applied in Korean transmission systems according to a rated voltage. In this paper, we conduct an evaluation of reclosing schemes in Korean transmission systems considering transient stability. Computer simulations are performed by using ElectroMagnetic Transient Program (EMTP) and transmission system is modeled based on actual data of Korea.

154kV 송전선로용 피뢰기 현장 설치 효과 분석 (Study on the effects of lightning arrestors installment on a 154kV transmission system)

  • 최한열;민병욱;박순규;이봉희;곽주식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 추계학술대회 논문집 전기설비전문위원
    • /
    • pp.9-11
    • /
    • 2008
  • Lightning has been identified as one of the leading causes of outages on transmission and distribution systems. To protect the transmission and distribution line from lightning, the transmission lightning arrestor can be the effective facility on the power system. This paper will discuss Gapped type Arresters application results by analysing effects of lightning arrestors on transmission and distribution line.

  • PDF

Available Transfer Capability Enhancement with FACTS Devices in the Deregulated Electricity Market

  • Manikandan, B.V.;Raja, S. Charles;Venkatesh, P.
    • Journal of Electrical Engineering and Technology
    • /
    • 제6권1호
    • /
    • pp.14-24
    • /
    • 2011
  • In order to facilitate the electricity market operation and trade in the restructured environment, ample transmission capability should be provided to satisfy the demand of increasing power transactions. The conflict of this requirement and the restrictions on the transmission expansion in the restructured electricity market has motivated the development of methodologies to enhance the available transfer capability (ATC) of existing transmission grids. The insertion of flexible AC transmission System (FACTS) devices in electrical systems seems to be a promising strategy to enhance single area ATC and multi-area ATC. In this paper, the viability and technical merits of boosting single area ATC and multi-area ATC using Thyristor controlled series compensator (TCSC), static VAR compensator (SVC) and unified power flow controller (UPFC) in single device and multi-type three similar and different device combinations are analyzed. Particle swarm optimization (PSO) algorithm is employed to obtain the optimal settings of FACTS devices. The installation cost is also calculated. The study has been carried out on IEEE 30 bus and IEEE 118 bus systems for the selected bilateral, multilateral and area wise transactions.

OFDM 이동통신 시스템의 Paging Indicator 전송 방식 (A Transmission Technique for Paging Indicator in OFDM-based Cellular Systems)

  • 김영준;유현일;우경수;이희수;조용수
    • 한국통신학회논문지
    • /
    • 제33권7A호
    • /
    • pp.710-719
    • /
    • 2008
  • 본 논문에서는 OFDM 기반 이동통신시스템에서 idle mode 단말의 전력 소모를 감소시키기 위하여 기존의 프리앰블에 PI(Paging Indicator) 정보를 추가하여 전송하는 기법을 제안한다. L1/L2 제어채널을 사용하여 PI를 전송하는 기법과 비교하여, 프리앰블을 이용하여 PI를 전송하는 기법은 PI 전송을 위한 추가의 overhead가 필요하지 않을 뿐만 아니라 PI 검출을 위한 복잡도도 감소시킬 수 있다. 본 논문에서는 OFDM 기반 이동통신시스템, 특히 mobile WiMAX 시스템에 적합한 동기화 기법과 PI 검출기법에 대하여 기술한다. 모의실험을 통하여 mobile WiMAX 시스템에서 동기화 성능과 셀 탐색 성능을 크게 열화시키지 않으면서 프리앰블(또는 common synch symbol)을 사용하여 PI를 전송할 수 있음을 확인한다.

지중송전계통에서 선로의 구성방식에 따른 자계 해석 (Magnetic Field Analysis in Accordance with Line Configuration Type in Underground Transmission Systems)

  • 이재명;이종범
    • 전기학회논문지
    • /
    • 제64권12호
    • /
    • pp.1673-1678
    • /
    • 2015
  • This paper describes magnetic field on power cable in underground transmission systems. Based on specification which is being used in domestic power utility, magnetic field was analyzed in accordance with line arrangement, line burial depth and phase spacing. Magnetic field magnitude and its trend were understood in each circuit type such as double circuits, triple circuits and quadruple circuits of underground transmission systems. In addition, magnetic field was analyzed according to phase arrangement changing in each circuit. Finally, the proper phase arrangement configuration type was suggested by the evaluation of analysis result. Magnetic field was calculated by using Biot-Savart's law. According to the evaluated magnetic fields based on phase layout configuration in each circuit, it figured out that each of magnetic fields was different. As a result, this paper proposes a proper phase layout configuration for generating minimum magnetic field. It is evaluated that the phase layout configuration in each circuit proposed in this paper can be used at actual underground transmission systems.

동력분기/순환구조 동력전달계의 정성적 성능 해석 (Analysis on the Qualitative Performance of a Power Split/Circulation Transmission)

  • 임원식;이동준;이장무;박영일
    • 한국자동차공학회논문집
    • /
    • 제3권6호
    • /
    • pp.212-223
    • /
    • 1995
  • To improve the efficiency of a power transmission system with slip elements, power split/circulation system is applied. The performance of a power split/circulation system varies widely by the change of the followings; the layout of system, the type and gear ratio of planetary gear, the performance of slip element, etc. Therefore, when one designs such a power transmission system or when one determines the economic/power mode of system, a certain performance prediction method is needed. In this study, the internal power flow pattern of a power split/circulation system is theoretically analyzed on several transmission systems. And an effective performance prediction method(so called performance locus diagram) is presented. By this method, the effects of design factors can be easily understood and the qualitative performances of system can be clearly evaluated.

  • PDF

A low-complexity PAPR reduction SLM scheme for STBC MIMO-OFDM systems based on constellation extension

  • Li, Guang;Li, Tianyun
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제13권6호
    • /
    • pp.2908-2924
    • /
    • 2019
  • Multiple input multiple output orthogonal frequency division multiplexing (MIMO-OFDM) is widely applied in wireless communication by virtue of its excellent properties in data transmission rate and transmission accuracy. However, as a major drawback of MIMO-OFDM systems, the high peak-to-average power ratio (PAPR) complicates the design of the power amplifier at the receiver end. Some available PAPR reduction methods such as selective mapping (SLM) suffer from high computational complexity. In this paper, a low-complexity SLM method based on active constellation extension (ACE) and joint space-time selective mapping (AST-SLM) for reducing PAPR in Alamouti STBC MIMO-OFDM systems is proposed. In SLM scheme, two IFFT operations are required for obtaining each transmission sequence pair, and the selected phase vector is transmitted as side information(SI). However, in the proposed AST-SLM method, only a few IFFT operations are required for generating all the transmission sequence pairs. The complexity of AST-SLM is at least 86% less than SLM. In addition, the SI needed in AST-SLM is at least 92.1% less than SLM by using the presented blind detection scheme to estimate SI. We show, analytically and with simulations, that AST-SLM can achieve significant performance of PAPR reduction and close performance of bit error rate (BER) compared to SLM scheme.

웨이브렛 변환을 이용한 혼합송전계통에서의 Fault Location (Fault Location in Combined Transmission Systems Using Wavelet Transform)

  • 정채균;홍동석;이종범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전력기술부문
    • /
    • pp.226-229
    • /
    • 2001
  • The combined transmission lines with the underground power cables are continuously expanded in power systems. So the fault of combined transmission line is increased every year as the complication of underground transmission line. In this paper. traveling wave theory and DWT wavelet transform are used for fast and accurate detection of fault location at the combined transmission line. Traveling wave travels to each bus like surge and repeats reflection and transmission till transient signal is completely disappeared. When fault is occurred on overhead and underground tine, the fault location detecting algorithm was performed with using continuous peak value time-delay of traveling wave reflected from A bus.

  • PDF

ANALYSIS OF PLANETARY GEAR HYBRID POWERTRAIN SYSTEM PART 1: INPUT SPLIT SYSTEM

  • Yang, H.;Cho, S.;Kim, N.;Lim, W.;Cha, S.
    • International Journal of Automotive Technology
    • /
    • 제8권6호
    • /
    • pp.771-780
    • /
    • 2007
  • In recent studies, various types of multi mode electric variable transmissions of hybrid electric vehicles have been proposed. Multi mode electric variable transmission consists of two or more different types of planetary gear hybrid powertrain system(PGHP), which can change its power flow type by means of clutches for improving transmission efficiencies. Generally, the power flows can be classified into three different types such as input split, output split and compound split. In this study, we analyzed power transmission characteristics of the possible six input split systems, and found the suitable system for single or multi mode hybrid powertrain. The input split system used in PRIUS is identified as a best system for single mode, and moreover we identified some suitable systems for dual mode.