• Title/Summary/Keyword: Power Transformer Fault

검색결과 260건 처리시간 0.026초

변압기결선에 따른 풍력발전시스템의 고장전류에 대한 시뮬레이션 (Simulation for fault current of wind turbine generating system following transformer winding connection)

  • 안해준;노경수
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2007년도 춘계학술대회 논문집
    • /
    • pp.454-457
    • /
    • 2007
  • This study suggests a modeling of grid-connected wind turbine generation system that has induction generator, and aims to perform simulations for outputs by the variation of actual wind speed and for fault current of wind generation system by the transformer winding connection. This study is implemented by MARTLB & SIMULINK. The simulation shall be performed by assuming single line to ground fault generated in the system Generator power, rotor speed, terminal voltage, system voltage, and fault current shall be observed following the performance of simulation. The fault current change will be dealt through the simulation results for fault current of wind generation system following the grid-connected transformer winding connection and the simulation result by the transformer neutral ground method.

변류기(p-CT)를 적용한 YBCO 초전도 저항형 한류기의 ?치 특성 (Quench Behaviors of Superconducting YBCO film for Fault Current Limiters applying Protective Current Transformer)

  • 박권배;이방욱;강종성;오일성;현옥배
    • Progress in Superconductivity
    • /
    • 제5권2호
    • /
    • pp.128-131
    • /
    • 2004
  • The resistive superconducting fault current limiters (SFCLs) are very attractive devices for the electric power network. But they have some serious problems when the YBCO thin films were used for the current limiting materials due to the in homogeneities caused by manufacturing process. When the YBCO films have some inhomogeneities, simultaneous quenches are difficult to achieve when the fault current limiting units are connected in series for increasing operating voltage ratings. Magnetic field application is one of the prospective way of inducing simultaneous quenches far the series-connected resistive FCL components. Magnetic field was typically generated by the fault current thorough a coil, which is connected to components of the fault current limiter in series, leaving the problem, which provides significant inductance to the power line and suppresses critical current density of the superconducting components. In this article we investigated the possible application of the protective current transformer (p-CT), which is available current source to the magnetic coil. This system inductively coupled to the circuit, therefore, remarkably reducing impedance to the circuit. The current by the protective current transformer was directly fed to the coil, generating magnetic field large enough to reduce critical current density of the components. This successfully induced simultaneous quenches of the series-connected resistive FCL components.

  • PDF

MATLAB/Simulink에서 계통연계 풍력발전시스템의 특성해석에 대한 시뮬레이션 (Simulation for Characteristics Analysis of Grid-connected Wind Power Generation System on MATLAB/Simulink)

  • 노경수;안해준
    • 조명전기설비학회논문지
    • /
    • 제22권8호
    • /
    • pp.18-25
    • /
    • 2008
  • 본 논문은 HATLAB/Simulink에서 계통연계 풍력발전시스템의 특성해석을 위한 모델링을 제안하여 시뮬레이션을 수행한다. 이를 위해 풍속의 변화에 따른 발전기의 출력제어를 위해 피치제어를 수행하며, 연계변압기의 결선방법에 따른 고장전류의 변화를 살펴봄으로 하여 연계변압기의 결선방법과 고장전류와의 상관관계를 제시하였다. 아울러 풍력발전시스템의 연계변압기 중성점접지방식이 고장전류에 미치는 영향을 살펴본다. 계통에서의 1선 지락고장에 대해 연계변압기의 4가지 결선방식의 차이에 따른 고장전류, 전압 및 발전기의 특성 변화를 확인할 수 있었으며 중성점 접지방식의 차이에 따른 고장전류의 변화를 확인하였다. 사례연구를 통하여 제안한 Simulink에서의 시뮬레이션 모델의 효용성을 입증하였다.

S파라미터를 이용한 단상 변압기의 이상 상태 진단에 대한 연구 (Diagnosis of Fault and Abnormal Conditions in a Single-Phase Transformer Using S-parameter Measurement)

  • 김정은;김광호;나완수
    • 전기학회논문지
    • /
    • 제67권10호
    • /
    • pp.1344-1352
    • /
    • 2018
  • In this paper, we propose a two-port S-parameter data to diagnose the fault conditions of a single-phase transformer. Using the S-parameters we can measure the reflection and transmission characteristics of signal power at the port of a transformer, which can also be converted into ABCD parameters and Z parameters through a well-known conversion formulas. Transformer fault diagnoses can be performed based on the intuitive and qualitative/quantitative characteristics of the these parameters. In addition, we can obtain wide frequency characteristics at the primary and secondary sides of the transformer, which can be used to get time domain responses using the inverse Fourier transformation with some specific input waveform. In order to verify the effectiveness of the proposed method, the fault conditions were analyzed in simulation and experiment for 3 kVA single phase transformer with 15: 5 turns ratio, and the validity of the proposed method was verified.

Comparative Analysis on Current Limiting Characteristics of Hybrid Superconducting Fault Current Limiters (SFCLs) with First Half Cycle Limiting and Non-Limiting Operations

  • Kim, Jin-Seok;Lim, Sung-Hun;Kim, Jae-Chul
    • Journal of Electrical Engineering and Technology
    • /
    • 제7권5호
    • /
    • pp.659-663
    • /
    • 2012
  • The application of large power transformer into a power distribution system was inevitable due to the increase of power demand and distributed generation. However, the decrease of the power transformer's impedance caused the short-circuit current of the power distribution system to be increase thus, the higher short-circuit current exceeded the cut-off ratings of the protective devices such as circuit breaker. To solve these problems, several countermeasures have been proposed to protect the power system effectively from higher fault current and the superconducting fault current limiter (SFCL) has been expected to be the promising countermeasure. In spite of excellent current limiting performances of the SFCL, on the other hand, the efforts to apply the SFCL into power system has been delayed due to both the limited spaces for the SFCL's installation and its long recovery time after the fault removal. In order to solve these problems, a hybrid SFCL, which can perform either first half cycle limiting of first half cycle non-limiting operation, has been developed by corporation of LSIS (LS Industrial System) and KEPCO (Korea Electric Power Corporation). In this paper, we tried to requirements hybrid SFCL by PSCAD/EMTDC. Simulation results of our analysis of the hybrid SFCL is that its accompanied the characteristics both the limit the fault current and quick recovery caused by the less impact from superconductor.

이중 ?치를 이용한 변압기형 초전도 한류기의 권선전류와 초전도소자 저항에 따른 전력소모 및 누적에너지 분석 (Analysis on Power Consumption and Accumulated Energy According to Resistance of Superconducting Element and Winding Current of Transformer Type SFCL Using Double Quench)

  • 한태희;임성훈
    • 한국전기전자재료학회논문지
    • /
    • 제29권10호
    • /
    • pp.630-634
    • /
    • 2016
  • In this paper, we analyzed the power consumption and the accumulated energy in HTSC (high-TC superconducting elements) according to the resistance of HTSC element and the winding current of transformer type SFCL (superconducting fault current limiter) using double quench. For the analysis, two different inductances of the one secondary winding among two secondary windings comprising the transformer type SFCL were selected and the short-circuit tests were carried out. The consumed power and the accumulated energy in HTSC element connected into the secondary winding with larger inductance were analyzed to be larger compared to the one connected into the secondary winding with lower inductance.

전력용변압기 단선 보호용 NGR 성능 개선 (The Improvement of NGR for Power Transformer Open Circuit Protection)

  • Kang, Y.W.;Shim, E.B.;Kwak, J.S.
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전기설비전문위원
    • /
    • pp.83-88
    • /
    • 2004
  • As the electric system is getting larger to meet the increasing demand for electric power, the rating of power apparatus is becoming inevitably higher in its working voltage and larger in its capacity. According to KEPCO reports, power transformers in the KEPCO system have undergone troubles such as winding short insulation breakdowns every year since 1981. the cause of this troubles were high one line grounding fault currents in KEPCO systems that had direct grounding systems. KEPCO has installed the NGR(neutral grounding reactor) to lower this fault current and reduced winding short insulation breakdowns in power transformers. But when a circuit breaker opened a no load bus, some trips of circuit breakers for protecting transformer have occurred by mal-operation of 59GT(overvoltage ground relay) that detect disconnection of NGR. Therefore, in this paper, we analyzed the cause and examined the effect of time delav circuit to prevent wrong operation of 59GT.

  • PDF

유중가스 분석법과 지능형 확률모델을 이용한 유입변압기 고장진단 (Fault Diagnosis of Oil-filled Power Transformer using DGA and Intelligent Probability Model)

  • 임재윤;이대종;지평식
    • 전기학회논문지P
    • /
    • 제65권3호
    • /
    • pp.188-193
    • /
    • 2016
  • It has been proven that the dissolved gas analysis (DGA) is the most effective and convenient method to diagnose the transformers. The DGA is a simple, inexpensive, and non intrusive technique. Among the various diagnosis methods, IEC 60599 has been widely used in transformer in service. But this method cannot offer accurate diagnosis for all the faults. This paper proposes a fault diagnosis method of oil-filled power transformers using DGA and Intelligent Probability Model. To demonstrate the validity of the proposed method, experiment is performed and its results are illustrated.

유중가스농도를 이용한 유입식 변압기 고장진단 기법의 신뢰성에 관한 연구 (A Study on the Reliability of Failure Diagnosis Methods of Oil Filled Transformer using Actual Dissolved Gas Concentration)

  • 박진엽;진수환;박인규
    • 전기학회논문지P
    • /
    • 제60권3호
    • /
    • pp.114-119
    • /
    • 2011
  • Large Power transformer is a complex and critical component of power plant and consists of cellulosic paper, insulation oil, core, coil etc. Insulation materials of transformer and related equipment break down to liberate dissolved gas due to corona, partial discharge, pyrolysis or thermal decomposition. The dissolved gas kinds can be related to the type of electrical faults, and the rate of gas generation can indicate the severity of the fault. The identities of gases being generated are using very useful to decide the condition of transformation status. Therefore dissolved gas analysis is one of the best condition monitoring methods for power transformer. Also, on-line multi-gas analyzer has been developed and installed to monitor the condition of critical transformers. Rogers method, IEC method, key gas method and Duval Triangle method are used to failure diagnosis typically, and those methods are using the ratio or kinds of dissolved gas to evaluate the condition of transformer. This paper analyzes the reliability of transformer diagnostic methods considering actual dissolved gas concentration. Fault diagnosis is performed based on the dissolved gas of five transformers which experienced various fault respectively in the field, and the diagnosis result is compared with the actual off-line fault analysis. In this comparison result, Diagnostic methods using dissolved gas ratio like Rogers method, IEC method are sometimes fall outside the ratio code and no diagnosis but Duval triangle method and Key gas method is correct comparatively.

FCM과 SOM을 이용한 전력용 변압기 고장진단 기법 (Fault Diagnosis Method of Power Transformer Using FCM and SOM)

  • 한운동;이대종;지평식
    • 한국콘텐츠학회논문지
    • /
    • 제7권3호
    • /
    • pp.25-33
    • /
    • 2007
  • 전력계통의 갑작스런 고장은 막대한 경제적 손실을 초래함으로 이를 방지하기 위한 전력계통의 상태를 진단하는 모니터링은 무엇보다도 중요하다. 본 논문에서는 FCM과 SOM을 이용하여 다양한 전력설비 중에서 가장 중요한 역할을 담당하는 전력용 변압기의 고장진단 알고리즘을 개발한다. 즉, FCM은 효과적인 특징점을 선택과 학습시간을 줄이기 위해 수행하고, SOM에 의해 변압기의 고장진단이 이루어진다. 제안된 방법은 변압기의 고장진단 뿐만 아니라 열화진행추이 특성까지 분석한다. 제안된 방법은 다양한 사례 연구를 통해 우수성을 입증하였다.