• 제목/요약/키워드: Power Transfer Function

검색결과 466건 처리시간 0.027초

전력선 통신채널의 시뮬레이터 개발 (Simulator Development for Power Line Communication Channel)

  • 박종연;정동열
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제49권9호
    • /
    • pp.546-553
    • /
    • 2000
  • W e have developed a power line simulator which is one of the basic tools for the research of the power line communication and its control system. In the developed simulators, we have considered the transfer function of the power line, noises and signal attenuation characteristics. Simulator was made using the matlab tool program. We made the power line modem using the FSK chip(ST7537) and experimentalized to show the efficiency grade of simulator. We have expected that the developed simulators are very useful in the area for the power line communication research and the control system design.

  • PDF

GA를 이용한 전류 앰프의 파라미터 최적화 (The Parameter Optimization of Current Amplifier with GA)

  • 양주호;정황훈;김영완
    • 동력기계공학회지
    • /
    • 제10권4호
    • /
    • pp.147-152
    • /
    • 2006
  • The current type amplifier is the device that is used for an actuator as the motor's torque controller. However, it is too difficult to select the parameter value that has the desired output because the current type amplifier's transfer function is too complex. This study concern about the design of the current type amplifier with the desired output. From the modeled transfer function of the current type amplifier, the optimal parameter values of the transfer function can be selected in order to have the desired output using the Real Coded Genetic Algorithm(RCGA). The real circuit is made with the selected parameter value. The step response of the real circuit is in good agreement with the desired step response.

  • PDF

A Novel Impedance Matching Topology for Magnetically Coupled Wireless Power Transfer

  • Lee, Gunbok;Park, Wee Sang
    • International journal of advanced smart convergence
    • /
    • 제1권2호
    • /
    • pp.16-19
    • /
    • 2012
  • A modified 4-coil magnetic resonance wireless power transfer (MRWPT) system is proposed. Four coils based on 2-coil system with additional two matching coils were used in this topology. When Tx-Rx distance is changed, the input impedance is changed. However, it can be adjusted by coil parameters of matching coils to maintain impedance matching for maximum efficiency. The equivalent circuit of MRWPT system was analyzed for both transmission function and optimum coupling coefficient of the matching coils. By using four spiral resonant coils, these design considerations was experimentally verified. The measured data agreed well with the calculated data and the transmission function of the proposed system was more efficient than that of conventional 2-coil system.

고체전달음 저감을 위한 음향전달 특성해석에 관한 연구 (The Study on the Analysis of the Acoustic Transfer Function for Reducing the Structure-borne Noise)

  • 김경모
    • 동력기계공학회지
    • /
    • 제6권3호
    • /
    • pp.57-63
    • /
    • 2002
  • This paper describes the acoustic analysis of mid duty truck. The focus of the analysis is on structure borne engine noise with major contributions of 2nd order. It has been previously recognized that the noise contribution of each transfer path of structure borne noise can be varied with the charateristics of each mounts and vibro acoustic sensitivity of car body. The structure of car body will be split up into three major sub components, which are modeled separately, the engine, the frame and the cab. The acoustic performance is evaluated on three levels: engine to frame transfer, frame to cab transfer, and panel contribution from cab to driver. In order to perform these analyses, analytical models are created for the engine, frame, cab and acoustic cavity. The models are linked through a coupled fluid structure calculation, and through FRF Based Substructuring for the structural couplings. Based on the structural coupling calculations, a transfer path analysis is performed to identify the most important transfer paths. These paths are then the focussing points for applying modifications to the structure or the mount system. Finally, a number of modification are proposed and their effect is quantified.

  • PDF

이천관측소에서 측정된 지자기장 및 지자기 전달함수의 시간적 변동성 (On the Temporal Variability of Geomagnetic Field and Transfer Function at Icheon Observatory)

  • 이덕기;권병두;윤용훈;양준모
    • 한국지구과학회지
    • /
    • 제25권7호
    • /
    • pp.604-614
    • /
    • 2004
  • 경기도 이천에서 2002년 7월부터 12까지 총 6개월 동안 측정된 지자기 3성분 자료를 이용하여 일별 각 성분의 스펙트럼, 지자기 전달함수의 크기, 위상, 오차 등을 계산하였다. 지자기 스펙트럼은 관측기간 동안 태양활동에 의한 무작위적 강약이 반복되는 형태를 보여주었고, 유의미한 시간적 변동은 존대하지 않았다. 지자기 전달함수의 크기, 위상, 오차의 경우, 주기 100초 이하와 주기 1000초 이상에서 부분적으로 무작위적인 경향을 확인할 수 있었으나, 시간에 따른 증감추세 없이 대체로 안정적인 값을 보였다. 이와 더불어, 전기장의 P$_{1}\;^{0}$ 소스(zonal harmonics) 가정을 통하여 시간에 따른 근사적인 겉보기 전기비저항의 변동을 조사하였는데, 근사된 전기비저항의 변화는 지각의 자체적인 물성 변화보다는 수평 자기장 성분의 시간적 강약에 지배적임을 확인할 수 있었다.

The Fault Diagnosis of a Transformer Using Neural Network and Transfer Function

  • Park, Byung-Koo;Kim, Jong-Wook;Kim, Sang-Woo;Park, Poo-Gyeon;Park, Tae-Joon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.127.2-127
    • /
    • 2001
  • A transformer is one of the most important elements in the power network. Transformer faults could cause costly repairs and be dangerous to personnel. To avoid this, its reliable operation has great significance and, therefore, the diagnosis system of the transformer is necessitated. The dissolved gas-in-oil analysis (DGA) is the worldwide popular method of detecting faults such as a hot spot or partial discharges inside the transformer. DGA, however, is not a reliable technique to identify aging phenomena and mechanical faults including insulation failure, inter-turn short, etc. To overcome the drawbacks of DGA, the transfer function method is used to identify effectively these kinds of the mechanical faults. The transformer has a unique transfer function independent of the shape of the input waveform, which can be evaluated through sweep test. This transfer function changes by winding ...

  • PDF

The state space of a canonical linear system

  • Yang, Mee-Hyea
    • 대한수학회지
    • /
    • 제32권3호
    • /
    • pp.447-459
    • /
    • 1995
  • A fundamental problem is to construct linear systems with given transfer functions. This problem has a well known solution for unitary linear systems whose state spaces and coefficient spaces are Hilbert spaces. The solution is due independently to B. Sz.-Nagy and C. Foias [15] and to L. de Branges and J. Ball and N. Cohen [4]. Such a linear system is essentially uniquely determined by its transfer function. The de Branges-Rovnyak construction makes use of the theory of square summable power series with coefficients in a Hilbert space. The construction also applies when the coefficient space is a Krein space [7].

  • PDF

Filtered Velocity Feedback 제어기를 이용한 양단지지보의 음향파워 저감 (Reduction of Sound Radiated Power of Clamped Beams using Filtered Velocity Feedback Controllers)

  • 신창주;홍진숙;정의봉
    • 한국소음진동공학회논문집
    • /
    • 제21권12호
    • /
    • pp.1104-1111
    • /
    • 2011
  • This paper investigates the filtered velocity feedback(FVF) controller for the reduction of the acoustic power radiated from a clamped beam. The instability problem due to the non-collocated sensor/actuator configuration when using PZT actuator should be sorted out. The roll-off property of the FVF controller at high frequency helps to alleviate the instability. The dynamics of clamped beams under forces and moments pair and the FVF controller are first formulated. The formulation of the sound radiated power is followed. The open loop transfer function(OLTF) synthesized with 100 modes is used to determine the stability of the control system. The control performance is finally estimated. The levels of the vibration and the sound radiated power are reduced in the wide bandbelow the tuning mode of the FVF controller.

Filtered Velocity Feedback 제어기를 이용한 양단지지보의 음향파워 저감 (Reduction of Sound Radiated Power of Clamped Beams using Filtered Velocity Feedback Controllers)

  • 신창주;홍진숙;정의봉
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2011년도 추계학술대회 논문집
    • /
    • pp.377-383
    • /
    • 2011
  • This paper reports the filtered velocity feedback (FVF) controller to reduce the acoustic power from clamped beams. The instability problem due to the non-collocated sensor/actuator configuration when using PZT actuator should be resolved. The roll-off property of the FVF controller at high frequency helps to alleviate the instability. The dynamics of clamped beams under forces and moments pair and the FVF controller are first formulated. The formulation of the sound radiated power is followed. The open loop transfer function (OLTF) synthesized with 100 modes is used to determine the stability of the control system. The control performance is finally estimated. The levels of the vibration and the sound radiated power are reduced in the wide band below the tuning mode of the FVF controller.

  • PDF

분포정수계 유압관로 모델의 동특성 해석 (Analysis of Dynamic Characteristics of Hydraulic Transmission Lines with Distributed Parameter Model)

  • 김도태
    • 드라이브 ㆍ 컨트롤
    • /
    • 제15권4호
    • /
    • pp.67-73
    • /
    • 2018
  • The paper deals with an approach to time domain simulation for closed end at the downstream of pipe, hydraulic lines terminating into a tank and series lines with change of cross sectional area. Time domain simulation of a fluid power systems containing hydraulic lines is very complex and difficult if the transfer functions consist of hyperbolic Bessel functions which is the case for the distributed parameter dissipative model. In this paper, the magnitudes and phases of the complex transfer functions of hydraulic lines are calculated, and the MATLAB Toolbox is used to formulate a rational polynomial approximation for these transfer functions in the frequency domain. The approximated transfer functions are accurate over a designated frequency range, and used to analyze the time domain response. This approach is usefully to simulate fluid power systems with hydraulic lines without to approximate the frequency dependent viscous friction.