• 제목/요약/키워드: Power Systems

검색결과 13,462건 처리시간 0.039초

Simulation Analysis of Control Methods for Parallel Multi-Operating System constructed by the Same Output Power Converters

  • Ishikura, Keisuke;Inaba, Hiromi;Kishine, Keiji;Nakai, Mitsuki;Ito, Takuma
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제3권3호
    • /
    • pp.282-288
    • /
    • 2014
  • A large capacity power conversion system constructed by using two or more existing power converters has a lot of flexibility in how the power converters are used. However, at the same time, it has a problem of cross current flows between power converters. The cross current must be suppressed by controlling the system while miniaturizing the combination reactor. This paper focuses on two current control methods of a power conversion system constructed by using two power converters connected in parallel supplying the same power. In order to elucidate the control performance of cross current, each control method which are aimed at controlling cross current and not directly controlling it are examined in simulations.

Cyber Threat and a Mitigation Method for the Power Systems in the Smart Grid

  • Kim, Myongsoo;Kim, Younghyun;Jeon, Kyungseok
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권3호
    • /
    • pp.1043-1050
    • /
    • 2014
  • Obsolescent control systems for power systems are evolving into intelligent systems and connecting with smart devices to give intelligence to the power systems. As networks of the control system are growing, vulnerability is also increasing. The communication network of distribution areas in the power system connects closely to vulnerable environments. Many cyber-attacks have been founded in the power system, and they could be more critical as the power system becomes more intelligent. From these environment, new communication network architecture and mitigation method against cyber-attacks are needed. Availability and Fault Tree analysis used to show that the proposed system enhances performance of current control systems.

Evaluation Algorithms for Multiple Function of Dispersed Electrical Energy Storage Systems

  • Son, Joon-ho;Choi, Sung-Sik;Rho, Dae-Seok
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권6호
    • /
    • pp.2245-2253
    • /
    • 2018
  • With the increase of electrical consumption and the unbalance of power demand and supply, power reserve rate is getting smaller and also the reliability of the power supply is getting deteriorated. Under this circumstance, the electrical energy storage (EES) System is considered as one of essential countermeasure for demand side management. This paper proposes efficient evaluation algorithms of multiple functions for EES systems, especially the secondary battery energy storage systems, in the case where they are interconnected with the power distribution systems. It is important to perform the economic evaluation for the new energy storage systems in a quantitative manner, because they are very costly right now. In this paper, the multiple functions of EES systems such as load levelling, effective utilization of power distribution systems and uninterruptible power supply are classified, and then the quantitative evaluation methods for their functions are proposed. From the case studies, it is verified that EES systems installed at distribution systems in a dispersed manner have multiple functions involved with direct and indirect benefits and also they can be expected to introduce to distribution systems with respects to economical point of view.

Wide-area Frequency-based Tripped Generator Locating Method for Interconnected Power Systems

  • Kook, Kyung-Soo;Liu, Yilu
    • Journal of Electrical Engineering and Technology
    • /
    • 제6권6호
    • /
    • pp.776-785
    • /
    • 2011
  • Since the Internet-based real-time Global Positioning System(GPS) synchronized widearea power system frequency monitoring network (FNET) was proposed in 2001, it has been monitoring the power system frequency in interconnected United States power systems and numerous interesting behaviors have been observed, including frequency excursion propagation. We address the consistency of a frequency excursion detection order of frequency disturbance recorders in FNET in relation to the same generation trip, as well as the ability to recreate by power systems dynamic simulation. We also propose a new method, as an application of FNET measurement, to locate a tripped generator using power systems dynamic simulation and wide-area frequency measurement. The simulation database of all the possible trips of generators in the interconnected power systems is created using the off-line power systems dynamic simulation. When FNET detects a sudden drop in the monitoring frequency, which is most likely due to a generation trip in power systems, the proposed algorithm locates a tripped generator by finding the best matching case of the measured frequency excursion in the simulation database in terms of the frequency drop detection order and the time of monitoring points.

철도 급전시스템 신뢰도 평가 연구 (A Study of Traction Power System Reliability)

  • 김형철;차준민;김진호;한문섭
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 춘계학술대회 논문집
    • /
    • pp.806-812
    • /
    • 2005
  • This paper proposes a new reliability evaluation for traction power system. The electric railway consists of traction power systems, various vehicles, operating equipment, track, overhead line and electric equipment. It is a fundamental function of traction power systems that supply customers with reasonable price, acceptable reliability and high quality power. In a general way, the power system reliability deals with the ability to satisfy load demands in supply capability or rating of every factor. On the other hand, the reliability of traction power systems has been focused on train time delay caused by power outage. In this paper, we make a selection optimum reliability indices for the reliability evaluation of electric traction power systems. The reliability study not only applies a plan for traction supply system after detecting the vulnerable point of existing traction supply systems but also makes a role in stable operating railway.

  • PDF

A Novel Photovoltaic Power Generation System including the Function of Shunt Active Filter

  • Park, Minwon;Seong, Nak-Gueon;Yu, In-Keun
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제3B권2호
    • /
    • pp.103-110
    • /
    • 2003
  • With significant development of power electronics technology, the proliferation of nonlinear loads such as static power converters has deteriorated power quality in power transmission and distribution systems. Notably, voltage harmonics resulting from current harmonics produced by the nonlinear loads have become a serious problem in many countries. Many photovoltaic power generation systems installed in building systems have harmonics that are the worst object for distribution systems as a utility interactive system, and it tends to spread out continuously. Proposed and implemented in this paper is a multi-function inverter control strategy that allows a shunt active filter function to the power inverter of the photovoltaic power generation system established on a building system. The effectiveness of the proposed system is demonstrated through the simulation of a hypothetical power system using PSCAD/EMTDC.

Definition of Powers and Power Quality Factors at a Point of Common Coupling in Single-Phase Systems and Three-Phase Systems

  • Kim, Hyosung;Frede Blaabjerg;Jensen, Birgitte-Bak
    • Journal of Power Electronics
    • /
    • 제2권1호
    • /
    • pp.32-45
    • /
    • 2002
  • This paper proposes an unified definition of powers for various circuit conditions such as balanced/unbalanced, sinusoidal/non-sinusoidal, and linear/nonlinear, fur single-phase systems and three-phase systems. Conventional reactive power is more classified into an interactive power and an alternating power. These powers are defined both in the time domain and the frequency domain consistently, and agree well with the conservation law. Several important power quality factors are defined to measure and evaluate the power quality fur the various circuits in the single-phase and three-phase systems. Simulation results show the power quality factors can evaluate and classify the various circuit conditions clearly.

Reliability Modeling of Direct Current Power Feeding Systems for Green Data Center

  • Choi, Jung Yul
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권4호
    • /
    • pp.704-711
    • /
    • 2013
  • Data center is an information hub and resource for information-centric society. Since data center houses hundreds to ten thousands servers, networking and communication equipment, and supporting systems energy saving is one of the hottest issues for green data center. Among several solutions for green data center this paper introduces higher voltage direct current (DC) power feeding system. Contrary to legacy alternating current (AC) power feeding system equipped with Uninterruptible Power Supply (UPS), higher voltage DC power feeding system is reported to be a more energy efficient and reliable solution for green data center thanks to less AC/DC and DC/AC conversions. Main focus of this paper is on reliability issue for reliable and continuous operation of higher voltage DC power feeding system. We present different types of configuration of the power feeding systems according to the level of reliability. We analyze the reliability of the power feeding systems based on M/M/1/N+1/N+1 queueing model. Operation of the power feeding system in case of failure is also presented.

퍼지제어를 이용한 비선형 2기 5모선 전력계통의 안정화 (Stabilization of nonlinear two-generator five-bus power systems using fuzzy control)

  • 문운철
    • 제어로봇시스템학회논문지
    • /
    • 제6권1호
    • /
    • pp.42-49
    • /
    • 2000
  • This paper presents the application of a FARMA controller to stabilization of nonlinear Two-Generator Five-Bus power Systems. The control rules and the membership functions of the FARMA controller are generated automatically without using any plant model high complexity and severe nonlinearity of power systems are introduced and two-Machine Five -Bus Power system stabilization problem is formulated. The simulation results demonstrate the effectiveness and application possibility of the FARMA controller to the control problem of high order and nonlinear plants.

  • PDF

Retrofit of Analog Boiler Control Systems with Digital Control Systems in a Thermal Power Plant

  • Park, Doo-Yong;Byun, Seung-Hyun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.1304-1308
    • /
    • 2005
  • This paper presents the case that the existing analog control systems were retrofitted with digital DCS(Distributed Control System)s for boiler unit in thermal power plant. Replacement of existing worn-out or obsolete analog control systems has been considered. Replacement of existing analog control systems with another analog control systems has lots of difficulties in maintaining the systems due to being out of stock. Due to those difficulties, existing analog control systems have been retrofitted with digital DCSs in many industrial sites. KEPRI(Korea Electric Power Research Institute) accomplished the project that retrofitted analog control systems with the developed DCSs for boiler unit in middle-scale coal-fired thermal power plant. The benefits of an upgrade to digital control include a increase of reliability due to system redundancy, ease of modifying the control logic and the parameters of function block, ease of maintenance due to available spare parts, improvement of information display, ease of modifying MMI(Man Machine Interface) displays, a increase in system availability, and improvement of control performance. This paper describes how to use the parameters of existing analog controllers, the implementation of digital PID controller, control system configuration for boiler unit in thermal power plant, some boiler control loops, control result during commissioning, and the comparison of boiler characteristic test data after retrofitting with the existing test data.

  • PDF