• 제목/요약/키워드: Power System Measurement

검색결과 2,050건 처리시간 0.036초

3차원 측정 로보트 셀 개발 (Development of 3-dimensional measuring robot cell)

  • 박강;조경래;신현오;김문상
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1991년도 한국자동제어학술회의논문집(국내학술편); KOEX, Seoul; 22-24 Oct. 1991
    • /
    • pp.1139-1143
    • /
    • 1991
  • Using industrial robots and sensors, we developed an inline car body inspection system which proposes high flexibility and sufficient accuracy. Car Body Inspection(CBI) cell consists of two industrial robots, two corresponding carriages, camera vision system, a process computer with multi-tasking ability and several LDS's. As industrial robots guarantee sufficient repeatabilities, the CBI cell adopts the concept of relative measurement instead of that of absolute measurement. By comparing the actual measured data with reference data, the dimensional errors of the corresponding points can be calculated. The length of the robot arms changes according to ambient temperature and it affects the measuring accuracy. To compensate this error, a robot arm calibration process was realized. By measuring a reference jig, the differential changes of the robot arms due to temperature fluctuation can be calculated and compensated.

  • PDF

A Comparative Study on Frequency Estimation Methods

  • Kim, Yoon Sang;Kim, Chul-Hwan;Ban, Woo-Hyeon;Park, Chul-Won
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권1호
    • /
    • pp.70-79
    • /
    • 2013
  • In this paper, a comparative study on the frequency estimation methods using IRDWT (Improved Recursive Discrete Wavelet Transform), FRDWT(Fast Recursive Discrete Wavelet Transform), and GCDFT(Gain Compensator Discrete Fourier Transform) is presented. The 345[kV] power system modeling data of the Republic of Korea by EMTP-RV is used to evaluate the performance of the proposed two kinds of RDWT(IRDWT and FRDWT) and GCDFT. The simulation results show that the frequency estimation technique based on FRDWT could be the optimal frequency measurement method, and thus can be applied to FDR(Fault Disturbance Recorder) for wide-area blackout protection or frequency measurement apparatus.

3차원 레이저 스캐너용 ND 필터의 시뮬레이션 (Simulation of ND Filter for Terrestrial Laser Scanner)

  • 양수효;오동근;정중연
    • 한국측량학회:학술대회논문집
    • /
    • 한국측량학회 2009년도 춘계학술발표회 논문집
    • /
    • pp.65-73
    • /
    • 2009
  • The terrestrial laser scanner measures the signal delay time of electronic circuit in EDM(Electronic Distance Measurement) Module for distance measurement. To measure signal delay time precisely, transmitting laser beam of terrestrial laser scanner is divided optically. Therefore, 10% of the laser beam power is entered into the electronic circuit and the others go out through lens. But, measure of delay time is severe in the laser scanner system that the laser beam power is changed dynamically by reflectance of a object, because characters like gain of electronic circuit involving APD(Avalanche Photo Diode) and so on are changed by incident laser beam. Therefore, we adapt ND(Neutral Density) filter that has grid pattern to the laser scanner system to keep constant the incident laser beam power. In this paper, we propose the simulation program for efficient design of ND filter pattern. Finally, to affirm simulation program, we conduct the experimental test of simulated ND filter that has linearly transmittance change, and we consider the experiment result.

  • PDF

변전소 고조파 측정 및 분석에 관한 연구 (A Study on Measurement and Analysis of Harmonics in Substation)

  • 한무호;박태준;이성희;이치환
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 전력전자학술대회 논문집
    • /
    • pp.438-441
    • /
    • 2001
  • Nonlinear loads change the sinusoidal nature of the ac power current, thereby resulting in the flow of harmonic currents in the ac power system that can cause interference with communication circuits and other type of equipment. To minimize the damage, it is needed to limit harmonics current and voltage. Harmonic measurement system was developed to measure individual voltage and current harmonic continuously and save harmonic data on computer. We measured all 154kV feeders in a steel making company substation. Voltage and current distortion limits for general transmission systems was suggested We found some feeders exceeded current distortion limits. As result voltage harmonic exceeded standard limits.

  • PDF

Non-contact monitoring of 3-dimensional vibrations of bodies using a neural network

  • Ha, Sung Chul;Cho, Gyeong Rae;Doh, Deog-Hee
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제39권10호
    • /
    • pp.1011-1016
    • /
    • 2015
  • Gas piping systems in power plants and factories are always influenced by the mechanical vibrations of rotational machines such as pumps, blowers, and compressors. Unusual vibrations in a gas piping system influence possible leakages of liquids or gases, which can lead to large explosive accidents. Real-time measurements of unusual vibrations in piping systems in situ prohibit them from being possible leakages owing to the repeated fatigue of vibrations. In this paper, a non-contact 3-dimensional measurement system that can detect the vibrations of a solid body and monitor its vibrational modes is introduced. To detect the displacements of a body, a stereoscopic camera system is used, through which the major vibration types of solid bodies (such as X-axis-major, Y-axis-major, and Z-axis-major vibrations) can be monitored. In order to judge the vibration types, an artificial neural network is used. The measurement system consists of a host computer, stereoscopic camera system (two-camera system, high-speed high-resolution camera), and a measurement target. Through practical application on a flat plate, the measured data from the non-contact measurement system showed good agreement with those from the original vibration mode produced by an accelerator.

배전용 접지전극의 안전성 분석 장치 구성 (The Construction of Safety Measurement Equipment of Grounding Electrode for Distribution System)

  • 강문호;박영근;장상옥;왕윤찬;이흥호
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2005년도 춘계학술대회논문집
    • /
    • pp.218-221
    • /
    • 2005
  • Grounding electrodes as discharge paths to the earth are normally used to ensure the safety of human body and facilities from the over-voltages in distribution power system, and each grounding mode has a prescribed ground resistance value respectively which is applied by the utilities. As the various electrodes for distribution power system are recently developing to improve the performance of them and resolve the problem of space restriction, it is necessary to measure and investigate the safety of human body of developed electrodes. Therefore, in this paper, we provide briefly a technical comparison of two standards, i.e. IEEE Std 80 and the IEC 479-1, and describe the configuration of safety measurement system which can measure the step voltage and the touch voltage of grounding electrodes based on IEEE Std 80.

  • PDF

노약자와 장애인의 건강상태를 모니터링하기 위한 소형 저 전력 휴대용 Bio-signal 측정 장치의 개발 (Development of Portable Power-Efficient Bio-Signal Monitoring System using Bluetooth for the elderly and the disabled)

  • 송길섭;정현권;송민;변증남;이희영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 합동 추계학술대회 논문집 정보 및 제어부문
    • /
    • pp.176-179
    • /
    • 2001
  • A portable bio-signal measurement system for 24-hours continuous health monitoring of the elderly and the disabled is presented. The measurement system has the functions of acquisition of various bio-signals such as ECG, EMG and EEG, wireless data transmission/receive and adjustment of parameters such as gain and cut-off frequency. The data is sent to a host computer or other device via a Bluetooth. The design targets of the developing system for volume and power consumption are $20{\times}30{\times}5(mm^3)$ and 8mW.

  • PDF

실시간 계측시스템을 이용한 전차선로 특성 측정 (Characteristic Measurement by a Real-time Data Acquisition System in Overhead Contact Wire)

  • 나해경;박영;조용현;이기원;박현준;오수영;송준태
    • 한국전기전자재료학회논문지
    • /
    • 제20권3호
    • /
    • pp.281-285
    • /
    • 2007
  • Facilities of electric railway should be maintained only at night and it is necessary to maintain by human power because facilities are installed at a high place. This paper presents the development and application of a real-time data acquisition system for the characteristics measurement of overhead contact wires in electric railway. The system is designed to perform in the telemetry environments that developed to store data by wireless in a live wire state of 25 kV power source. The field test results show that the proposed technique and the developed system can be practically applied to measure characteristics of temperature, displacement, and strain on overhead contact lines.

DSP를 이용한 전력 측정 시스템의 외란 신호 분석 및 개선을 위한 시스템 구현 (The realization for power measurement system to analyze and improve the external distortion with DSP)

  • 김자환;류광렬
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2003년도 추계종합학술대회
    • /
    • pp.233-235
    • /
    • 2003
  • 본 논문은 전력 측정 시스템에서 가지고 있는 외란 신호에 의해 전력 손실에 대한 분석 및 개선하기 위한 시스템이다. 절약 특성 시스템 구현은 RF모듈, DSP 모듈, 통신모듈로 구성되고 외란 제거는 위그너 분포 알고리즘을 적용하였다. 실험은 기지국 시스템과 연동하여 측정 하였고, 측정 결과 기존 시스템보다 약 $\pm$0.5dB 정도 개선이 되었다.

  • PDF

광역계통 전압/무효전력 관리를 위한 전압관리시스템의 개발 및 현장설치 (Development and Installation of Voltage Management System for Voltage and Reactive Power Control of Wide Area System)

  • 남수철;신정훈;백승묵;이재걸;문승필;김태균
    • 전기학회논문지
    • /
    • 제59권9호
    • /
    • pp.1540-1548
    • /
    • 2010
  • KEPCO proposes enhanced voltage management system that is a coordinate voltage control system between the hierarchical voltage control system and the slow voltage control system. It has been installing in Jeju island. VMS consists of a master controller, CVC (Continuous Voltage Controller) and DVC (Discrete Voltage Controller). CVC consists of main controller, FDMU (Field Data Measurement Unit) and several RPDs (Reactive Power Dispatcher). CVC has a control scheme with AVRs of generator to maintain the voltage of a pilot bus in a power system, DVC has a control scheme with static reactive power sources, like a shunt capacitor, a shunt reactor, ULTC and so on, to maintain the reactive power reserve of a power system and a master controller is executed to recover reactive power margin of a power system through coordinated control between CVC and DVC.