• 제목/요약/키워드: Power System Measurement

검색결과 2,042건 처리시간 0.03초

이산 적응슬라이딩 모드 제어를 이용항 전력계통 안정화 장치에 관한 연구 (A study on the power system stabilizer using discrete-time adaptive sliding mode control)

  • 박영문;김욱
    • 대한전기학회논문지
    • /
    • 제45권2호
    • /
    • pp.175-184
    • /
    • 1996
  • In this paper the newly developed discrete-time adaptive sliding mode control method is proposed and applied to the power system stabilization problem. In contrast to the conventional continuous-time sliding mode controller, the proposed method is developed in the discrete-time domain and based on the input/output measurements instead of the continuous-time and the full-states feedback, respectively. Because the proposed control method has the adaptivity property in addition to the natural robustness property of the sliding mode control, it is possible to design the power system stabilizer which can overcome both the minor variations of the parameters of the power system and the diverse operating conditions and faults of the power system. Mathematical proof and the various computer simulations are done to verify the performance and stability of the proposed method.

  • PDF

초음파 파워 측정 시스템 구성 및 성능평가 (Construction of Ultrasonic Power Measurement System and Its Performance Evaluation)

  • 조문재;김용태;윤용현;정성수
    • 한국음향학회지
    • /
    • 제24권8호
    • /
    • pp.431-440
    • /
    • 2005
  • 초음파 파워의 정확한 측정은 초음파 의료 장비의 품질 보증과 안전성에 중요하다. 본 논문에서는 초음파 조사가 on/off를 반복하는 동안의 표적에 작용하는 방사 힘과 부력과 같은 다른 원인에서 기인하는 저울 지시 값의 시간에 따른 변화로부터 초음파 파워를 결정하는 간단한 이론을 제시하였다. 아울러 개발된 초음파 파워 측정 시스템에 대해 정밀 기계적 정렬장치, 전기신호 발생부 구성, 제어 및 측정부 구성 및 적절한 절차와 함께 상세히 기술하였다. 본 시스템으로 1 MHz, 5 MHz, 10 MHz, 15 MHz에서 10 mW에서 10 W범위에 걸쳐 측정된 결과를 다른 나라에서 교정된 기준 데이터와 상호 비교한 결과 상대 편차가 $5\%$ 이내로 확인되었다.

Measurement of Noise and Speed in the EMR using Power Line Network

  • Song, Yong-soo;Yoon, Sung-Won;Cho, Young-Bin;Lee, Chung-Keun;Min, Se-Dong;Nam SuK Bang;Lee, Myung-Ho
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2002년도 ICCAS
    • /
    • pp.58-58
    • /
    • 2002
  • Recently Many technologies of the P.L.N (Power Line Network) are introduced for an efficient communication. P.L.N transmits information using power line channel. A medical information transmission system is proposed in this paper for the effective transmission. The Power Line Networks have an advantage in low cost because it uses existent power line. It can be easily applied anywhere that a power line socket is available. But the power line channel is very noisy, because many electronic devices in generate electronic noise in modulated signals. This problem should be considered carefully in the design of medical information transmission system using P.L.N. The proposed system can be applied...I propose a telemedicine system using the power line network.

  • PDF

개방형 스페이서를 가진 가스절연개폐장치(GIS)의 극초단파대 외부잡음 유입 측정 (Measurement of UHF noise penetration into the barrier and bushing of the open barrier type gas-insulated switch gear(GIS))

  • 박기준;임재섭;구선근;윤진열
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1618-1619
    • /
    • 2003
  • 개방형 스페이서(barrier)가 적용된 가스 절연개폐장치(GIS)에 외장형 부분방전(PD) 센서를 적용 하고 센서장착부, 인근 스페이서 또는 부싱으로 유입되는 광대역 잡음신호의 투과율을 10 - 2000 MHz의 극초단파 영역에서 측정하였다. 또한 간단한 금속 차폐체에 의한 잡음신호의 감쇄효과도 측정 하였다. 스페이서 또는 부싱을 통하여 인근센서에 유입되는 잡음의 크기는 차폐시와 대비하여 약 25 dB 증가하였다.

  • PDF

Field-Measurement-Based Received Power Analysis for Directional Beamforming Millimeter-Wave Systems: Effects of Beamwidth and Beam Misalignment

  • Lee, Juyul;Kim, Myung-Don;Park, Jae-Joon;Chong, Young Jun
    • ETRI Journal
    • /
    • 제40권1호
    • /
    • pp.26-38
    • /
    • 2018
  • To overcome considerable path loss in millimeter-wave propagation, high-gain directional beamforming is considered to be a key enabling technology for outdoor 5G mobile networks. Associated with beamforming, this paper investigates propagation power loss characteristics in two aspects. The first is beamwidth effects. Owing to the multipath receiving nature of mobile environments, it is expected that a narrower beamwidth antenna will capture fewer multipath signals, while increasing directivity gain. If we normalize the directivity gain, this narrow-beamwidth reception incurs an additional power loss compared to omnidirectional-antenna power reception. With measurement data collected in an urban area at 28 GHz and 38 GHz, we illustrate the amount of these additional propagation losses as a function of the half-power beamwidth. Secondly, we investigate power losses due to steering beam misalignment, as well as the measurement data. The results show that a small angle misalignment can cause a large power loss. Considering that most standard documents provide omnidirectional antenna path loss characteristics, these results are expected to contribute to mmWave mobile system designs.

무선센서를 이용한 지하전력구의 케이블 접속함 표면온도감시시스템 개발 (A Development of Surface Temperature Monitoring System for Underground Tunnel Cable Joint using Wireless Sensor)

  • 김영일;송재주;신진호;이봉재;조선구
    • 전기학회논문지
    • /
    • 제56권11호
    • /
    • pp.1879-1884
    • /
    • 2007
  • In the electric power industry, it is important that the supply of energy must be guaranteed. Many power utilities control and supervise the transmission line to avoid power failures. In case of underground tunnel, some troubles are reported in cable joint. To stabilize the power, it is needed to monitor the cable joint. Many researches of cable joint monitoring have been going on by partial discharge measurement and temperature measurement using optical cable. These methods need much cost to install and maintain, so it is only used in critical transmission line. In this research, we use wireless sensor technology, because of its low cost and easy installation. We develop the temperature monitoring system for cable joint. Temperature sensor is installed on the surface of cable joint and sends data to server through router node using wireless network. Generally Ad hoc routing is searched in wireless network. However, in this research, we design the static linear routing mechanism, which is suitable for electric power line monitoring and analyze the life time of the sensor node by measuring the amount of the battery consumption.

A Study on Lightning Overvoltage Characteristics of Grounding Systems in Underground Distribution Power Cables

  • Jung, Chae-Kyun;Jung, Yeon-Ha;Kang, Ji-Won
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권2호
    • /
    • pp.628-634
    • /
    • 2014
  • This paper investigates the transient characteristics of grounding systems used in under-ground distribution power cables. Recently, two kinds of grounding system are used for underground distribution cables in Korea. The first one is conventional multi-point grounding system, the other is newly proposed non-bundled common grounding system. The non-bundled common grounding system has an advantage the decreasing the power loss due to decrease of the shield circulation current. In this paper, the lightning overvoltage induced in neutral wire (in case of non-bundled common grounding system, overvoltage between opened neural wires and grounding in each phase) of these two kinds of grounding systems are estimated and compared by field tests and EMTP simulations. The EMTP simulation methods are firstly verified by comparison of measurement and simulation. Finally, the insulation level against lightning is expected by EMTP simulation results using verified model.

제어 자유도를 한 차원 증가시킨 순시무효전력 보상이론 (Instantaneous Reactive Power Compensation Theory Increasing The Control Freedom One Degree Higher)

  • 김효성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 F
    • /
    • pp.2481-2483
    • /
    • 1999
  • This paper proposed the p-q-r coordinate system where the instantaneous active power p, and the two instantaneous reactive powers $q_{q}$, $q_{r}$ were defined. The three power components are linearly independent, so the compensation for the two instantaneous reactive powers leads to control the two components of the current space vector. With the theory, the neutral current of a three-phase four-wire system can be eliminated by only compensating the instantaneous reactive power using no energy storage element.

  • PDF

전력 시스템 감시 제어용 광센서 기술 (Optical Sensor Technology for Supervisory and Control of Electric Power System)

  • 김영수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.2189-2191
    • /
    • 2000
  • Electric power systems are becoming advanced by using new technology year by year However, in electric power system environments. electromagnetic interference occurs in measurement, supervisory and control systems, especially in sensors. Optical sensor technologies are useful for solving the problem, since they are not affected by electromagnetic interference because they are composed of insulting materials. In this paper, some applications of optical sensor technology to electric power systems are introduced.

  • PDF

온라인 전력계통 고장 진단 시스템 개발 (On Line Fault Diagnosis in the Large Power System)

  • 김정년;백영식;서규석
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제54권5호
    • /
    • pp.205-211
    • /
    • 2005
  • Recently, power system is getting larger and more complex. When the complex power system has a problem, it is very difficult even for the experts to find out where the problem is and to make a timely decision by operators. There have been many studies on these problems but the results are not good enough for applying to real power system. Therefore, power system operators always had to judge the exact state of power system and be preparative for the problems that can occur later. We developed new methods that can be applied to complex power system by dividing the system into small modules. By using 'module', we can combine small modules together to make complex power systems and the knowledge base that is applied to fault diagnosis system. As a result, compared to previously developed diagnosis products, operation time is shortened and the knowledge base is become simpler and clearer, which made online usage capable. This system can be used as a complementary measurement that helps the operator from making any mistakes.