• 제목/요약/키워드: Power System Measurement

검색결과 2,042건 처리시간 0.032초

Experimental verification and improvement of heat transfer tube local wall temperature measurement method

  • Jiabao Liu;Xiaxin Cao;Peixun Yang
    • Nuclear Engineering and Technology
    • /
    • 제55권12호
    • /
    • pp.4317-4328
    • /
    • 2023
  • To ensure the measuring accuracy of the wall temperature, the outer wall temperature measurement values by using three kinds of thermocouple welding methods were analyzed and evaluated in the paper, including single-point flush-mounted in the wall groove method, single-point insert-mounted in the wall groove, and outer surface direct welding method, based on the application of a tube-in-tube condensing heat exchanger. And the impacts of silver, tin, and thermal resistance adhesive as filling materials on wall temperature measurement were also investigated, and the results were compared to that obtained without filling materials. The results showed that the wall temperatures measured by the three welding methods were lower than the theoretically calculated value. And the wall temperature measured by the outer surface direct welding method was lowest under the same experimental conditions. The wall temperatures measured by single-point flush-mounted and insert-mounted in the wall groove methods were also affected by different welding filling materials. It was found that the greater the thermal resistance of filling materials, the smaller the heat loss. By analyzing the reasons for the low measured value of wall temperature, a new wall temperature measurement method was developed to improve the accuracy of the current measurement method. Meanwhile, the outer wall temperature measurement experiments of vertical and horizontal heat transfer tubes were carried out to validate and calibrate the improved outer wall temperature measurement method. The results showed that the average outer wall temperature deviation measured by the improved wall temperature measurement method ranged from - 0.82% to +2.29% for vertical tubes and - 4.75% to - 1.44% for horizontal tubes, and the improved measurement method had good measurement accuracy.

계통연계 풍력발전기의 전력품질 평가를 위한 IEC 61400-21 표준 실시간 계측 장치 구현 (An Implementation of Real-time Measurement and Assessment System for Power Quality Characteristics of Grid Connected Wind Turbines)

  • 이종주;김동준;문영환
    • 전기학회논문지
    • /
    • 제59권9호
    • /
    • pp.1560-1565
    • /
    • 2010
  • The renewable resource are getting more attentions with increased concerns on the depletion of fossil fuels and several environmental issues like emission problem. Wind power is a representative option among several renewable sources and the generation capacity using wind power is being increased. However, the wind generation is so volatile on its output characteristic, so it is required to assess the grid impact of wind power generation by measuring the fluctuation effect more precisely. This paper proposes the method for measuring the generation output according to IEC 61400-21(Measurement and assessment of power quality characteristics of grid connected wind turbines) to assess the power quality of wind turbine generation. In addition, it shows an application case to a small-scale wind power generator. In the case study, it suggests a structure design of the proposed measurement instrument both on hardware and software aspects, which is composed of a remote monitoring & data analysis program and an FPGA based real-time signal processing device.

3상 전력을 기반으로 한 시스템 해석 컴퓨터 (Computer Based Three Phase Power Analysing System)

  • 위제;박영태
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.675-676
    • /
    • 2008
  • The computer based three phase power analysing system has been developed as a traveling standard for onsite power calibration. The system is utilized with digital-to-analog converts which were synchronized each other. Using digital signal processing technique the software has been developed to calculate power parameters. The calibration system is fully traceable to national standard system and, accuracy allows the calibration of industrial power measurement systems.

  • PDF

태양광 발전 시스템의 노이즈 감소와 상태추정을 위한 비선형 제어기 설계 (Nonlinear Controller Design for Noise Reduction and State Estimation in the Photovoltaic Power Generation System)

  • 김일송
    • 전력전자학회논문지
    • /
    • 제14권4호
    • /
    • pp.261-267
    • /
    • 2009
  • 최대전력점 추적기는 태양광 발전시스템의 대표적인 기능이다. 최대 전력점을 추종하기 위해서는 태양전지의 전압과 전류의 측정을 필요로 한다. 만약 측정 신호에 노이즈가 포함되어 있으면 발생되는 전력이 감소되어 태양광 발전의 효율이 감소하게 된다. 노이즈가 포함된 신호에 확장 칼만 필터 이론을 적용하여 최적의 추정된 신호를 얻어 낼 수 있다. 칼만 필터는 랜덤 노이즈가 포함된 신호에서 최적의 신호를 얻어내는데 사용된다. 또한 칼만 필터의 적용결과로 인덕터 전류와 같은 측정하지 않는 신호도 센서리스 추정이 가능하다. 본 논문에서는 시스템 모델링 방법과 확장 칼만 필터 설계 방법이 소개된다. 실험 결과로서 제안된 제어기의 성능을 확인하였다.

Kalman-Filter Based Static Load Modeling of Real Power System Using K-EMS Data

  • Lee, Soo-Hyoung;Son, Seo-Eun;Lee, Sung-Moo;Cho, Jong-Man;Song, Kyung-Bin;Park, Jung-Wook
    • Journal of Electrical Engineering and Technology
    • /
    • 제7권3호
    • /
    • pp.304-311
    • /
    • 2012
  • So far, the importance for an accurate load model has been constantly raised and its necessity would be further more emphasized. Currently used load model for analysis of power system in Korea was developed 10 years ago, which is aggregated by applying the statistically estimated load compositions to load models based on individual appliances. As modern appliances have diversified and rapidly changed, the existing load model is no longer compatible with current loads in the Korean power system. Therefore, a measurement based load model is more suitable for modern power system analysis because it can accurately include the load characteristics by directly measuring target load. This paper proposes a ZIP model employing a Kalman-filter as the estimation algorithm for the model parameters. The Kamlan-filter based parameter identification offers an advantage of fast parameter determination by removing iterative calculation. To verify the proposed load model, the four-second-interval real data from the Korea Energy Management System (K-EMS) is used.

MICS 표준에 기반한 무선 텔레메트리 시스템 개발 (Development of a wireless telemetry system based on MICS standard)

  • 이승하;박일용
    • 센서학회지
    • /
    • 제18권1호
    • /
    • pp.63-71
    • /
    • 2009
  • It is said that the desirable bio-signal measurement and stimulation system should be an implantable type if the several problems such as biocompatibility, electrical safety, and so on are overcome. In addition to the biocompatibility issue, a robust RF communication and a stable electrical power source for the implantable bio-signal measurement and stimulation system are very important matters. In this paper, a wireless telemetry system which adopts the FCC's approved MICS (medical implant communication service) protocol and a wireless power transmission has been proposed. The proposed system composed of a base station (BS) and an implantable medical device (IMD) has the advantages that the interference with other RF devices can be reduced by the use of the specially assigned MICS frequency band of 402.MHz to 405 MHz. Also, the proposed system includes various functions of a multi-channel bio-signal acquisition and an electric stimulation. Since the electrical power for the IMD can be provided by the inductive link between PCB patterned coils, the IMD needs no battery so that the IMD can be smaller size and much less dangerous than the active type IMD which includes the internal battery. Finally, the validity as a wireless telemetry system has been demonstrated through the experiments by using the implemented BS and IMD.

농용 트랙터의 승차(乘車) 진동(振動) 평가에 관한 연구(II) - 승차 진동 측정 및 분석 시스템의 개발 - (Evaluation of Ride Vibration of Agricultural Tractors(II) - Development of a Measurement and Analysis System of Ride Vibrations -)

  • 정수식;문계송;김경욱
    • Journal of Biosystems Engineering
    • /
    • 제17권4호
    • /
    • pp.326-335
    • /
    • 1992
  • This study was carried out to develop a measurement and analysis system of ride vibrations of tractors. The system consists of a portable digital computer, a PCL-812 PG interface card for A/D conversion, two accelerometers, two signal conditioners, a DC-AC power inverter and a DC power supplier. The computer programs installed in the system for data acquisition and analysis were also developed. It was intended that the system should be cheap enough to be afforded by college laboratories but reliable in its functions of measurement and analysis. Characteristics of the components and methods used in the system development were discussed.

  • PDF

이산웨이블릿을 이용한 전력외란 측정 시스템 (Power disturbance measurement system using discrete wavelet transform)

  • 이진목;김홍균;최재호;이상훈
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(1)
    • /
    • pp.177-181
    • /
    • 2003
  • Need of power stability, reliability is increased, as using of sensitive: nonlinear load are increasing. Therefore, Power Quality Problems become the center of public interest. Many kinds of algorithms have been studied for monitoring of Power Quality Problems. Monitoring algorithms of using RMS, FT and the others are easy to applicate to system. But, it is not enough to monitor all of Foyer. Quality problems. Wavelet Transform is more proper to applicate. so, This paper presents measurement system using discrete wavelet transform.

  • PDF

등가등방성복사전력 기반의 기지국 출력 관리를 위한 측정 연구 (A Study on measurement for effective isotropic radiated power based power management of the base stations)

  • 임재춘;김종헌;문성원;이영환
    • 한국ITS학회 논문지
    • /
    • 제10권6호
    • /
    • pp.118-125
    • /
    • 2011
  • 본 논문에서는 WCDMA 실험 기지국을 구성하여 가시거리상에서 측정된 pilot 채널의 수신 전력을 이용하여 기지국의 등가등방성복사전력을 구하였다. 측정시스템은 실험 기지국과 수신부로 구성하였으며 기지국의 pilot 채널인 CPICH 채널 전력을 측정하여 측정 시 발생하는 오차에 대한 보정계수를 고려하였다. 측정값으로부터 계산된 기지국의 등가등방성복 사전력은 기지국에서 설정한 등가등방성복사전력과 비교하여 약 0.5 dB 이하의 오차를 나타내었다.

고출력 레이저광 측정을 위한 계측 장치 제작 및 성능 평가 (A development and evaluation of the high power laser measurement system)

  • 황대석;최종운;이영우
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2003년도 춘계종합학술대회
    • /
    • pp.410-413
    • /
    • 2003
  • 고출력 레이저광 출력측정 및 교정을 위한 계측 장치를 제작하고 성능 평가에 관한 연구를 수행하였다. 계측 장치의 수광부는 금 코팅된 구리재질의 공동을 사용하여 제작되었다. 교정용 히터는 망가닌으로 제작되고, 출력 측정은 망가닌과 구리의 저항 브릿지를 사용하여 측정하였다. 외부 환경의 영향을 줄이기 위해 칼로리미터 내부의 온도를 5mK이하로 일정하게 하였다. 고출력 레이저 에너지의 측정을 위해 교정 인자와 보정 계수를 측정을 통하여 구하였다. 교정 인자는 100W 범위에서 489.13 J/mV 이고 500W 범위에서 497.04 J/mV이다. Nd:YAG Laser를 이용하여 보정 계수를 구한 결과 100W범위일 때는 0.99이고 500W범위일 때는 1.006으로 레이저 에너지와 전기적 교정의 차이는 1%이하이다.

  • PDF