• 제목/요약/키워드: Power Station

검색결과 1,320건 처리시간 0.028초

청송 양수발전소 시공사례 (A Case Study on the Chungsong Pumped-storage power station Construction)

  • 홍창수;이현구;도종열
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2006년도 추계 학술발표회
    • /
    • pp.169-178
    • /
    • 2006
  • The pumped-storage power system is the one of the hydroelectric power systems, generating electricity with hydraulic head difference. In this system, the electricity is produced during the hours of peak demand by using water that has been pumped into an upper reservoir from a lower reservoir during the hours of low demand. Generally, the system consists of an under-ground power house and tunnels such as the headrace, pressure, and tailrace tunnels. The Chungsong pumped-storage power station is the sixth one In the pumped-storage power station in Korea. Both the regional self-government and the population of chungsong -Goon had made a great effort to draw this power station construction into this area. The proposed Chungsong pumped-power station construction project was accepted by the central government as a part of the national electricity plan for the first time in Korea.

  • PDF

등가등방성복사전력 기반의 기지국 출력 관리를 위한 측정 연구 (A Study on measurement for effective isotropic radiated power based power management of the base stations)

  • 임재춘;김종헌;문성원;이영환
    • 한국ITS학회 논문지
    • /
    • 제10권6호
    • /
    • pp.118-125
    • /
    • 2011
  • 본 논문에서는 WCDMA 실험 기지국을 구성하여 가시거리상에서 측정된 pilot 채널의 수신 전력을 이용하여 기지국의 등가등방성복사전력을 구하였다. 측정시스템은 실험 기지국과 수신부로 구성하였으며 기지국의 pilot 채널인 CPICH 채널 전력을 측정하여 측정 시 발생하는 오차에 대한 보정계수를 고려하였다. 측정값으로부터 계산된 기지국의 등가등방성복 사전력은 기지국에서 설정한 등가등방성복사전력과 비교하여 약 0.5 dB 이하의 오차를 나타내었다.

Research Progress of the Structure Vibration-Attitude Coordinated Control of Spacecraft

  • Yang, Jingyu;Qu, Shiying;Lin, Jiahui;Liu, Zhiqi;Cui, Xuanming;Wang, Chu;Zhang, Dujiang;gu, Mingcheng;Sun, Zhongrui;Yang, Kang;Zhou, Lanwei;Chen, Guoping
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제16권4호
    • /
    • pp.590-601
    • /
    • 2015
  • This paper gives an overview of research on the field of structure vibration-attitude coordinated control of spacecraft. First of all, the importance of the technology has been given an introduction, and then later the research progress of space structure dynamics modeling, research progress of structure vibration-attitude coordinated control of flexible spacecraft have been discussed respectively. Finally, future research on application of structure vibration-attitude coordinated control of spacecraft has been recommended.

수·변전설비의 안전 환경 설치에 관한 국내외 규정 비교 분석 (Comparison and Analysis of Domestic and Foreign Standard for Solely Environment Installation of Power Station)

  • 배석명;김한상;방선배;이건호
    • 조명전기설비학회논문지
    • /
    • 제19권5호
    • /
    • pp.45-53
    • /
    • 2005
  • 국내산업의 발달 및 경제 성장과 더불어 전력설비의 대용량화 및 다양한 전기설비의 보급으로 인하여 수변전설 비도 증가되고 있으며 또한 대형화 되어 지고 있는 추세이다. 이러한 수$\cdot$변전설비에서의 안전 및 설비사고도 점차 증가되고 있는 실정이다. 따라서 본 논문에서는 수$\cdot$변전설비의 안전 환경 설치를 연구대상으로 하여 국내외 규정 및 기준에 대하여 비교 하였으며, 이를 통해 수$\cdot$변전설비의 설치시의 문제점을 도출하여 우리나라의 수$\cdot$변전설비 안전 환경 설치에 적용할 수 있도록 관련 규정의 개정(안)을 제시하였다.

Mobile WiMAX 기지국의 최적 출력파워 도출에 관한 연구 (A Study on the Output Power Optimization of Mobile WiMAX Base Station)

  • 김성만
    • 한국통신학회논문지
    • /
    • 제35권4A호
    • /
    • pp.341-349
    • /
    • 2010
  • 본 논문은 차세대 이동통신 기술로 주목받고 있는 IEEE 802.16 기반의 Mobile WiMAX (또는 WiBro) 시스템에서 여러 가지 채널환경조건 및 기지국의 조건을 고려하여 기지국의 출력파워를 최적으로 설계하는 방법에 관한 것이다. 본 논문에서는 다양한 환경조건에서 Mobile WiMAX 시스템의 상/하향 링크버짓(link budget)을 산출하여, 이로부터 Mobile WiMAX 기지국의 최적 출력파워를 도출하는 방법에 대해 정리하였다. 본 논문에서는 MIMO(multiple input multiple output) 기술이 적용된 기존의 2Tx-2Rx 기지국과 여기에 수신단의 감도를 높이기 위해 수신단의 안테나 개수를 4개로 늘린 2Tx-4Rx 기지국과 성능을 향상시키기 위해 새롭게 빔포밍(beamforming) 기술이 적용된 4Tx-4Rx 기지국의 경우 등 총 세 가지 경우에 대하여 최적 출력파워를 도출하였다.

Incorporating Station Related Aging Failures in Bulk System Reliability Analysis

  • Billinton Roy;Yang Hua
    • KIEE International Transactions on Power Engineering
    • /
    • 제5A권4호
    • /
    • pp.322-330
    • /
    • 2005
  • This paper proposes methods to incorporate station related aging failures in composite system reliability assessment. Aging failures of station components, such as circuit breakers and bus bars, are a major concern in composite power system planning and operation as an increasing number of station components approach the wear-out phase. This paper presents probabilistic models for circuit breakers involving aging failures and relevant evaluation techniques to examine the effects of station related aging outages. The technique developed to incorporate station related aging failures are illustrated by application to a small composite test system. The paper illustrates the effects of circuit breaker aging outages on bulk system reliability evaluation and examines the relative effects of variations in component age. System sensitivity analysis is illustrated by varying selected component parameters. The results show the implications of including component aging failure considerations in the overall analysis of a composite system.

Geophysical investigations for deciding alignment of head race tunnel and location of lake tapping at Koyna hydroelectric project, Maharashtra, India

  • Wadhwa R. S.;Chaudhari M. S.;Chandrasekhar V.;Saha A.;Mukhopadhyay R.
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 한국지구물리탐사학회 2003년도 Proceedings of the international symposium on the fusion technology
    • /
    • pp.370-378
    • /
    • 2003
  • Continuous seismic refraction, reflection and echo-sounder surveys conducted at Koyna Project site provided geotechnical information which helped in choosing the alignment for Head race tunnel and in designing and choosing the site for Lake Tap. Seismic refraction survey both on land and in shallow water determined depths to bedrock and helped in inferring the bedrock quality. Seismic reflection survey mapped the subsurface stratigraphy with high resolution. Reservoir-bed and bedrock contours drawn from the results of the survey helped in choosing the tunnel alignment and the lake tap position cost effectively. It was inferred from the results of the survey that the geology and the quality of rock do not change unexpectedly around the site for extension of Head race tunnel and the lake tapping. The bedrock levels evaluated by seismic survey agreed remarkably well with those inferred in boreholes having Rock Quality Designation 90 percent or more.

  • PDF

도시철도 역사 신재생에너지 활용을 위한 멀티레벨 인버터 개발 (Multilevel Inverter Development to Utilize Renewable Energy in Urban Railway Station)

  • 신승권;김형철;정호성;박종영;현병수
    • 전기학회논문지
    • /
    • 제64권2호
    • /
    • pp.324-330
    • /
    • 2015
  • Energy Saving Methods in existing railway vehicle are considered by active approach such as regenerative energy storage and utilization, eco driving, etc. On the other hands, energy saving measures in railway station are operated by passive method such as reduction of operating time in ventilation system, cooing system and power equipment. To reduce energy and for independence in railway system, it requires an active energy saving measures. It needs to its own power source besides the power source of electric supply company such as renewable energy and regenerative energy and take the advantage of power storage system and stored power are used in optimum time. This paper deal with 3-level NPC inverter and T-type NPC inverter that used in various multi-level topology applicable to the railway system.

큐브위성 송수신시험을 위한 실내용 지상국 구축 (Construction of Indoor Ground Station for Cubesat Communication Test)

  • 한상혁;문상만;신동엽;문성태;공현철;최기혁
    • 항공우주기술
    • /
    • 제13권2호
    • /
    • pp.73-79
    • /
    • 2014
  • 큐브위성 비행 소프트웨어 개발과정에서 큐브위성과 지상국간 데이터 송수신 시험이 필요한데 지상국 구축 비용과 공간성 등을 고려해 야외용 안테나를 사용하지 않는 실내용 지상국이 적합하다. 실내용 지상국 구축시 송신 출력이 높으면 큐브위성 통신시스템의 고장을 유발할 수 있음으로 지상국의 송신 출력이 큐브위성 통신시스템의 수신 허용범위 안에 있도록 설계하고, 이를 검증해야 한다. 본 논문에서는 UHF 및 VHF 주파수를 사용하는 큐브위성과의 데이터 송수신을 위한 실내용 지상국 구축에 대해 기술한다. 특히, 송신 출력을 저감하기 위한 방법으로 감쇄기를 사용하였는데, 송신단에 감쇄기를 연결하여 송신 출력과 감쇄기 수에 따른 감쇄 정도를 측정하고 이의 결과를 분석하여 기술하였다.

The Analysis of Activity on Removal from Operation of the Chernobyl Atomic Power Station, Experience of the First Year After Closing Power Station

  • Kravchenko, Georgiy;Jung, Ki-Jung
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 2002년도 춘계공동학술발표회요약집
    • /
    • pp.319.2-319
    • /
    • 2002
  • removal from operation of power units of nuclear stations in the various counties last decade the usual phenomenon. Good practice on a successful conclusion from operation of power units in Japan. USA is turned out. Germany, Russia and other countries. The features inherent in the Chernobyl atomic power station make this process especial, unique.

  • PDF