• Title/Summary/Keyword: Power Shift

Search Result 1,060, Processing Time 0.032 seconds

Conservative Approximation-Based Full-Search Block Matching Algorithm Architecture for QCIF Digital Video Employing Systolic Array Architecture

  • Ganapathi, Hegde;Amritha, Krishna R.S.;Pukhraj, Vaya
    • ETRI Journal
    • /
    • v.37 no.4
    • /
    • pp.772-779
    • /
    • 2015
  • This paper presents a power-efficient hardware realization for a motion estimation technique that is based on the full-search block matching algorithm (FSBMA). The considered input is the quarter common intermediate format of digital video. The mean of absolute difference (MAD) is the distortion criteria employed for the block matching process. The conventional architecture considered for the hardware realization of FSBMA is that of the shift register-based 2-D systolic array. For this architecture, a conservative approximation technique is adapted to eliminate unnecessary MAD computations involved in the block matching process. Upon introducing the technique to the conventional architecture, the power and complexity of its implantation is reduced, while the accuracy of the motion vector extracted from the block matching process is preserved. The proposed architecture is verified for its functional specifications. A performance evaluation of the proposed architecture is carried out using parameters such as power, area, operating frequency, and efficiency.

EMG Power Spectral Analysis on Masticatory Muscle Fatigue in Chronic Muscle Pain Patients (근전도 power spectrum을 이용한 만성근육동통 환자에 있어서의 저작근 피로에 관한 연구)

  • 이채훈;김영구;임형순
    • Journal of Oral Medicine and Pain
    • /
    • v.22 no.1
    • /
    • pp.145-155
    • /
    • 1997
  • The purpose of this study was to compare differences in endurance time and EMG power spectral characteristics of the masticatory muscles during sustained isometric contraction between patients and controls. 15 CMD patients{8 women and 7 men, aged 15 to 38 years(24.1$\pm$7.5)}, and 15 healthy volunteers{8 women and 7 men, aged 15 to 30 years(24.7$\pm$3.4)} without past history or present symptoms of CMD were included in this study. Sustained isometric contractions of masticatory muscles were perfomeed as long as possible at 50% level of maximum voluntary contraction(MVC) of EMG activity via visual feedback, and the duration of sustained isometric contraction(endurance time) was examined. The author perfomed EMG power spectral analysis in the myoelectric signals of masseter and anterior temporal muscle during sustained isometric contraction in CMD patients with chronic muscle pain and healthy controls. The author came to following conclusions from the results. 1. The endurance time of the patient group was shorter than the control group in sustained isometric contraction of masticatory muscles(p<0.01). 2. MF values of masticatory muscles with sustained isometric contraction during endurance time were decreased following regression line in both groups(p<0.01, r>0.9). 3. The amount of MF shift to lower frequency range exhibited no significant differences between the patients and the control group in sustained isometric contraction during endurance time. 4. SMF to lower frequency range of the patient group was steeper than the control group in sustained isometric contraction during endurance time(p<0.05).

  • PDF

Study on High Efficiency Boosting-up Circuit for Renewable Energy Application (신재생에너지용 연계형 인버터의 고효율 승압에 관한 연구)

  • Jung, Tae-Uk;Kim, Ju-Yong;Choi, Se-Kwon;Cho, Jun-Seok;Kho, Hee-Seok
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.336-339
    • /
    • 2009
  • In this paper, such as battery power or solar energy and fuel cells generated from Renewable energy sources, high voltage to low voltage DC-DC Converter for converting the design of the study. System consists of low voltage ($24{\sim}28$ [VDC]) and Boosts the voltage (270 [VDC]) for a 3 [kW] DC-DC converter and control circuit is configured as, Power switch the ST Tomson's Automotive low voltage high current MOSFET switches STE250NS10S (temperature 250A) was applied to the two parallel. Also, Controller's processor used ATMEGA128, and Gate Drive applies and composed Photo Coupler TLP250. development. Input voltage (24V) and output voltage (270V) for Conversion in the H-bridge converter topology of the circuit output side power and voltage to control the implementation of the Phase shift angle control applied. And, 3kW of power to pass appropriate specification of the secondary side as interpreted by the high frequency transformer, and the experimental production and analysis of the experiment

  • PDF

A Control Method to Improve Power Conversion Efficiency of Three-level NPC-Based Dual Active Bridge Converter (Three-Level NPC-Based Dual Active Bridge Converter의 도통손실 절감을 위한 새로운 스위칭 방법)

  • Lee, Jun-Young;Choi, Hyun-Jun;Kim, Ju-Yong;Jun, Jee-Hoon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.22 no.2
    • /
    • pp.150-158
    • /
    • 2017
  • This study proposes a new pulse-width modulation switching pattern for the low conduction loss of a three-level neutral point clamped (NPC)-based dual-active bridge (DAB) converter. The operational principle for a bidirectional power conversion is a phase-shift modulation. The conventional switching method of the three-level NPC-based DAB converter shows a symmetric switching pattern. This method has a disadvantage of high root-mean-square (RMS) value of the coupling inductor current, which leads to high conduction loss. The proposed switching method shows an asymmetrical pattern, which can reduce the RMS value of the inductor current with lower conduction loss than that of the conventional method. The performance of the proposed asymmetrical switching method is theoretically analyzed and practically verified using simulation and experiment.

The development of radiation lifetime measuring module for KAEROT/m2 (KAEROT/m2용 방사선 수명 측정모듈 개발)

  • Lee, Nam-Ho;Kim, Seung-Ho;Kim, Yang-Mo
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.793-796
    • /
    • 2003
  • The electronics of a mobile robot ill nuclear facilities is required to satisfied the reliability to sustain survival in its radiation environment. To know how much radiation the robot has been encountered to replace sensitive electronic parts, a dosimeter to measure total accumulated dose is necessary. Among many radiation dosimeters or detectors, semiconductor radiation sensors have advantages in terms of power requirements and their sires over conventional detectors. This paper describes the use of the radiation-induced threshold voltage change of a commercial power pMOSFET as an accumulated radiation dose monitoring mean and that of the photo-current of a commercial PIN Diode as a dose-rate measurement mean. Commercial p-type power MOSFETs and PIN Diodes were tested in a Co-60 gamma irradiation facility to see their capabilities as radiation sensors. We found an inexpensive commercial power pMOSFET that shows good linearity in their threshold voltage shift with radiation dose and a PIN diode that shows good linearity in its photo-current change with dose-rate. According to these findings, a radiation hardened hybrid electronic radiation dosimeter for nuclear robots has been developed for the first time. This small hybrid dosimeter has also an advantage in the point of view of reliability improvement by using a diversity concept.

  • PDF

Development of Low voltage DC-DC converter for xEV with high frequency·high power density based on GaN-HEMT and Planar transformer (GaN소자와 평면변압기를 이용한 700kHz 차량용 DC-DC컨버터 개발)

  • Kim, Sang-jin;Adhistira, Adhistira;Kim, Kyu-young;Choi, Se-wan;Yang, Dae-ki;Hong, Seok-yong;Lee, Youn-sik;Yeo, In-yong
    • Proceedings of the KIPE Conference
    • /
    • 2019.07a
    • /
    • pp.348-349
    • /
    • 2019
  • 본 논문은 전기자동차용 8.1kW/L의 높은 전력밀도를 갖는 저전압 DC-DC 컨버터(Low-voltage DC-DC converter, LDC)의 설계 방법을 제안한다. 넓은 전압범위에서 높은 전력밀도를 성취하기 위해 위상천이 풀-브릿지(Phase Shift Full-Bridge, PSFB) 컨버터의 2차측 토폴로지 후보군의 비교를 통해 전류-더블러 토폴로지로 토폴로지가 선정되었다. 또한 자속 상쇄 기법이 적용된 매트릭스 변압기를 적용한 PSFB 컨버터와 냉각기의 구조설계를 통해 8.1kW/L의 전력밀도를 달성하였으며 1.8kW 시작품을 제작하여 성능을 검증하였다.

  • PDF

Output Voltage Control Technique Using Current Forward Compensation for Phase Shifted Full Bridge Converter Without Output Capacitor (출력 커패시터가 없는 위상천이 풀브릿지 컨버터의 전류 전향 보상을 이용한 출력 전압 제어 기법)

  • Shin, You-Seung;Baek, Seung-Woo;Kim, Hag-Wone;Cho, Kwan-Yual;Kang, Jeong-Won
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.27 no.1
    • /
    • pp.40-47
    • /
    • 2022
  • At present, the low-voltage, high-current type power supply is mainly used for effective sterilization in the ballast water treatment system. Research on PSFB converters without output capacitors has been ongoing. Such converters effectively treat ballast water without a separate disinfectant through electric pulses by applying a pulse-type power to the output electrode without an output capacitor. However, in the case of the pulse-type electrolysis treatment method, voltage overshoot can occur due to abrupt voltage fluctuations when the load changes, resulting in circuit reliability problems because of the output capacitorless system. Therefore, a new voltage control algorithm is required. In this paper, we will discuss voltage control for pulsed electrolysis topology without an output capacitor. The proposed voltage control method has been verified using Simulation and experiment. The usefulness of the proposed control method has been proven by the experimental results.

Ultra-Low Power MICS RF Transceiver Design for Wireless Sensor Network (WSN 을 위한 초저전력 MICS RF 송수신기 기술 개요 및 설계 기법)

  • Gyu-won Kim;Yu-jung Kim;Junghwan Han
    • Transactions on Semiconductor Engineering
    • /
    • v.2 no.1
    • /
    • pp.9-16
    • /
    • 2024
  • This paper discusses the design of bio-implanted ultra-low-power MICS RF transceivers for wireless sensor networks. The 400 MHz MICS standard was considered for the implementation of the WBAN wireless sensor system, indirectly minimizing radio propagation losses in the human body and the inference with surrounding networks. This paper includes link budget, various transmission and reception architectures for a system design and ultra-low power transceiver circuit techniques for the implementation of RF transceivers that meet MICS standards.

Development of Auto Tracking System for Baseball Pitching (투구된 공의 실시간 위치 자동추적 시스템 개발)

  • Lee, Ki-Chung;Bae, Sung-Jae;Shin, In-Sik
    • Korean Journal of Applied Biomechanics
    • /
    • v.17 no.1
    • /
    • pp.81-90
    • /
    • 2007
  • The effort identifying positioning information of the moving object in real time has been a issue not only in sport biomechanics but also other academic areas. In order to solve this issue, this study tried to track the movement of a pitched ball that might provide an easier prediction because of a clear focus and simple movement of the object. Machine learning has been leading the research of extracting information from continuous images such as object tracking. Though the rule-based methods in artificial intelligence prevailed for decades, it has evolved into the methods of statistical approach that finds the maximum a posterior location in the image. The development of machine learning, accompanied by the development of recording technology and computational power of computer, made it possible to extract the trajectory of pitched baseball from recorded images. We present a method of baseball tracking, based on object tracking methods in machine learning. We introduce three state-of-the-art researches regarding the object tracking and show how we can combine these researches to yield a novel engine that finds trajectory from continuous pitching images. The first research is about mean shift method which finds the mode of a supposed continuous distribution from a set of data. The second research is about the research that explains how we can find the mode and object region effectively when we are given the previous image's location of object and the region. The third is about the research of representing data into features that we can deal with. From those features, we can establish a distribution to generate a set of data for mean shift. In this paper, we combine three works to track baseball's location in the continuous image frames. From the information of locations from two sets of images, we can reconstruct the real 3-D trajectory of pitched ball. We show how this works in real pitching images.

Comparison of Quench Methods in The Coal Gasification System with Carbon Capture (CO2 포집을 포함한 석탄 가스화 시스템에서 급냉 방법에 따른 비교)

  • Lee, Joong-Won;Kim, Ui-Sik;Ko, Kyung-Ho;Chung, Jae-Hwa;Hong, Jin-Pyo
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.23 no.3
    • /
    • pp.285-292
    • /
    • 2012
  • The integrated gasification combined cycle (IGCC) system is well known for its high efficiency compared with that of other coal fueled power generation system. IGCC offers substantial advantages over pulverized coal combustion when carbon capture and storage (CCS) is required. Commercial plants employ different types of quenching system to meet the purpose of the system. Depending on that, the downstream units of IGCC can be modeled using different operating conditions and units. In case with $CO_2$ separation and capture, the gasifier product must be converted to hydrogen-rich syngas using Water Gas Shift (WGS) reaction. In most WGS processes, the water gas shift reactor is the biggest and heaviest component because the reaction is relatively slow compared to the other reactions and is inhibited at higher temperatures by thermodynamics. In this study, tehchno-econimic assessments were found according to the quench types and operating conditions in the WGS system. These results can improve the efficiency and reduce the cost of coal gasification.