• Title/Summary/Keyword: Power Saving Control

검색결과 407건 처리시간 0.028초

에너지절감을 위한 태양광발전설비 연계형 경관조명 전력제어시스템의 개발 (An Development of Landscape Lighting Power Control System with Solar Cell Generator Equipment for Energy Saving)

  • 김동완;박성원
    • 전기학회논문지P
    • /
    • 제59권4호
    • /
    • pp.364-371
    • /
    • 2010
  • In this paper, we propose the landscape lighting power control system with solar sell generator equipment for energy saving, and also which is included the landscape lighting power transformation device. The power transformation device can check inverse current in the power of the solar cell module and control the power of the battery. And we present the design of landscape lighting power control system. The power control system uses microprocessor with charging system and power transformation device. And also it can control the power of loads under consideration intensity of illumination. The landscape lighting loads are composed of LED(Lighting Emitting Diode) and HID(High Intensity Discharge)lamps. To evaluate property, we installed the solar cell array which generate three kilo watt power. Experimental results show that the proposed system can have stability and energy saving on the mixed configuration of electric loads with DC and AC lamps.

The Energy Saving for Separately Excited DC Motor Drive via Model Based Method

  • Udomsuk, Sasiya;Areerak, Kongpol;Areerak, Kongpan
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권2호
    • /
    • pp.470-479
    • /
    • 2016
  • The model based method for energy saving of the separately excited DC motor drive system is proposed in the paper. The accurate power loss model is necessary for this method. Therefore, the adaptive tabu search algorithm is applied to identify the parameters in the power loss model. The field current values for minimum power losses at any load torques and speeds are calculated by the proposed method. The rule based controller is used to control the field current and speed of the motor. The experimental results confirm that the model based method can successfully provide the energy saving for separately excited DC motor drive. The maximum value of the energy saving is 48.61% compared with the conventional drive method.

IP 주소 제한을 이용한 PC 절전 시스템 보안 설계 (A Design of PC Power-Saving System Security Using IP Address Restriction)

  • 김홍윤
    • 디지털산업정보학회논문지
    • /
    • 제9권3호
    • /
    • pp.49-57
    • /
    • 2013
  • Power-saving PC software enables the inexpensive power control, but the installation of the power-saving software in all computers in the organization is not an easy task. Computer users in the organization are usually not cooperative as they do not think the power-saving cost is directly related to themselves. The PC power-saving system provides advantage to driving active participation in which users installs the power saving software by restricting IP address through the power management server. However, the problem with this approach is the security vulnerability to IP spoofing attacks, therefore we need to solve the problem that disrupt the entire network system rather than saving electric power. This paper proposes the security authentication system that can implement the efficiency saving power by providing high security for the members' computer system of the public institutions based on the PC power-saving system. Also, by analyzing it in comparison with other method, it is possible to check that the prospects of safety and efficiency are strengthened.

전력사용량 기반의 새로운 부하제어 알고리즘 (An New Load Control Algorithms based on Power Consumption)

  • 김정욱
    • 전기학회논문지
    • /
    • 제59권9호
    • /
    • pp.1658-1662
    • /
    • 2010
  • This paper presents an advanced energy saving algorithm in building. It is important to aggregate a various demand side resource which is surely controllable at the peak power time to reduce the energy cost. Previous demand side algorithm appropriate for building is based on peak power. In this paper, we develop the new energy saving algorithm to reduce the quantity of power consumption. The simulation results show that the proposed tem is very effective.

이동 애드혹 네트워크에서 생존시간 최대화를 위한 전력절감과 라우팅 결합 알고리즘 (Joint Power-Saving and Routing Algorithm for Lifetime Maximization in Mobile Ad Hoc Networks)

  • 최현호
    • 한국정보통신학회논문지
    • /
    • 제17권12호
    • /
    • pp.2826-2834
    • /
    • 2013
  • 이동 애드혹 네트워크에서 단말의 전력절감과 관련된 기술은 송신전력제어(transmit power control; TPC), 전력절감모드(power-saving mode; PSM), 라우팅(routing)으로 나뉠 수 있다. TPC와 PSM은 주로 하위 물리 및 데이터링크 계층에서 담당하는 반면 라우팅은 상위 네트워크 계층에서 담당하므로 이들 알고리즘들이 하나의 목적을 위해 보다 나은 성능을 제공하기 위해서는 통합된 관점에서의 알고리즘 설계가 필요하다. 따라서 본 논문에서는 애드혹 네트워크에서 주어진 종단간 전송률을 만족시키면서 전송 경로의 생존시간을 최대화하는 것을 목적으로 전력절감과 라우팅의 결합 알고리즘을 제안한다. 제안 방안은 먼저 단말의 송신전력을 줄이기 위하여 TPC 또는 PSM을 적용하여 개별 단말의 생존시간을 증가시키고, 이후 결정된 노드 생존시간을 고려하여 라우팅을 수행함으로써 멀티홉 전체 경로의 생존시간을 극대화한다. 시뮬레이션 결과 제안방식은 네트워크의 단말 수 및 간섭량의 변화에 따라 요구 전송률을 만족시키면서 생존시간을 극대화시킨다.

Efficient Power-Saving 10-Gb/s ONU Using Uplink Usage-Dependent Sleep Mode Control Algorithm in WDM-PON

  • Lee, Han Hyub;Kim, Kwangok;Lee, Jonghyun;Lee, Sangsoo
    • ETRI Journal
    • /
    • 제35권2호
    • /
    • pp.253-258
    • /
    • 2013
  • We propose and demonstrate an efficient power-saving optical network unit (ONU) based on upstream traffic monitoring for 10-Gb/s wavelength division multiplexed passive optical networks (WDM-PONs). The power-saving mode controller uses a ${\mu}$-processor and traffic monitoring modules followed by the proposed power-saving processes to operate the sleep mode ONU. The power consumption of the ONU is effectively reduced from 19.3 W to 6.4 W when no traffic from the users is detected. In addition, we design a power-saving mechanism based on a cyclic sleep mode operation to allow a connectivity check between the optical line terminal and ONU. Our calculation results show that the WDM-PON ONU reduces the power consumption by around 60% using the proposed mechanism.

IP 주소 제한을 이용한 PC 절전 시스템의 설계 (A Design of Power-saving PC System Using the IP Address Restriction)

  • 김홍윤
    • 디지털산업정보학회논문지
    • /
    • 제9권2호
    • /
    • pp.89-97
    • /
    • 2013
  • The green IT technology is being introduced in diverse sectors, especially in the data center and green computer sectors. Rack-type PCs, which have been developed by improving the computer hardware, are effective for data centers and large businesses, but they are not usually introduced in small organizations such as small and medium businesses and schools because they require high initial costs. Power-saving PC software enables the inexpensive power control, but the installation of the power-saving software in all computers in the organization is not an easy task. Computer users in the organization are usually not cooperative as they do not think the power-saving cost is directly related to themselves. In this paper, a technique wherein the server has a restriction in providing the IP address to the computers that has no power-saving software is proposed, so that users will cooperate in the PC power-saving system to avoid inconvenience. In order to provide restricted IP address periodically, the server makes a request of power-saving software installation check for user's PC. Proposed technique is more effective ways to save computer energy, because it does not depend on specific systems or organizations.

전기에너지 절약을 위한 조명제어시스템 (Light Control System For The Saving of Electric Energy)

  • 한승호;김성철;최경식
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 추계학술대회 논문집
    • /
    • pp.289-292
    • /
    • 2008
  • This paper represents the electric energy saving using light control system. Without Light Control System(LCS), it is very hard to classify the amount of electric energy saving for lighting, since it is determined by the end-user's preference in times. Typical LCS has an fixed algorithm to control each light's intensity by ON/Off Control, Step Control, or Dimming Control. We have studied the electric energy saving effect in a LCS equiped building with natural lighting. The electric power consumption at the peak power consumption time with LCS reduced up to 65% of the non-controled case.

  • PDF

OpenADR 기반의 전력사용량 관리 알고리즘 (Power Consumption Management Algorithm Based on OpenADR)

  • 김정욱
    • 제어로봇시스템학회논문지
    • /
    • 제22권12호
    • /
    • pp.991-994
    • /
    • 2016
  • This paper presents a load management method based on OpenADR of smart grid. Previous demand side algorithm is restricted on reducing peak power. But, in this paper we suggest a method of performing the energy-saving control according to the power price utilizing building automatic control system installed on the customer side in the case of hourly differential pricing signal is transmitted to the open automated demand response system. And, we showed the integrated demand management software for 3 buildings.

DUAL DUTY CYCLE CONTROLLED SOFT-SWITCHING HIGH FREQUENCY INVERTER USING AUXILIARY REVERSE BLOCKING SWITCHED RESONANT CAPACITOR

  • Bishwajit, Saha;Suh, Ki-Young;Lee, Hyun-Woo;Mutsuo, Nakaoka
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.129-131
    • /
    • 2006
  • This paper presents a new ZVS-PWM high frequency inverter. The ZVS operation is achieved in the whole load range by using a simple auxiliary reverse blocking switch in parallel with series resonant capacitor. The operating principle and the operating characteristics of the new high frequency circuit treated here are illustrated and evaluated on the basis of simulation results. It was examined that the complete soft switching operation can be achieved even for low power setting ranges by introducing the high frequency dual duty cycle control scheme. In the proposed high frequency inverter treated here, the dual mode pulse modulation control strategy of the asymmetrical PWM in the higher power setting ranges and the lower power setting ones, the output power of this high frequency inverter could introduce in order to extend soft switching operation ranges. Dual duty cycle is used to provide a wide range of output power regulation that is important in many high frequency inverter applications. It is more suitable for induction heating applications the operation and control principle of the proposed high frequency inverter are described and verified through simulated results.

  • PDF