• 제목/요약/키워드: Power Response

검색결과 3,876건 처리시간 0.031초

Modified Digital Pulse Width Modulator for Power Converters with a Reduced Modulation Delay

  • Qahouq, Jaber Abu;Arikatla, Varaprasad;Arunachalam, Thanukamalam
    • Journal of Power Electronics
    • /
    • 제12권1호
    • /
    • pp.98-103
    • /
    • 2012
  • This paper presents a digital pulse width modulator (DPWM) with a reduced digital modulation delay (a transport delay of the modulator) during the transient response of power converters. During the transient response operation of a power converter, as a result of dynamic variations such as load step-up or step-down, the closed loop controller will continuously adjust the duty cycle in order to regulate the output voltage. The larger the modulation delays, the larger the undesired output voltage deviation from the reference point. The three conventional DPWM techniques exhibit significant leading-edge and/or trailing-edge modulation delays. The DPWM technique proposed in this paper, which results in modulation delay reductions, is discussed, experimentally tested and compared with conventional modulation techniques.

On Power System Frequency Control in Emergency Conditions

  • Bevrani, H.;Ledwich, G.;Ford, J. J.;Dong, Z.Y.
    • Journal of Electrical Engineering and Technology
    • /
    • 제3권4호
    • /
    • pp.499-508
    • /
    • 2008
  • Frequency regulation in off-normal conditions has been an important problem in electric power system design/operation and is becoming much more significant today due to the increasing size, changing structure and complexity of interconnected power systems. Increasing economic pressures for power system efficiency and reliability have led to a requirement for maintaining power system frequency closer to nominal value. This paper presents a decentralized frequency control framework using a modified low-order frequency response model containing a proportional-integral(PI) controller. The proposed framework is suitable for near-normal and emergency operating conditions. An $H_{\infty}$ control technique is applied to achieve optimal PI parameters, and an analytic approach is used to analyse the system frequency response for wide area operating conditions. Time-domain simulations with a multi-area power system example show that the simulated results agree with those predicted analytically.

Design of Battery System for Smoothing Wind Power Variations in Power System based on Frequency Response Analysis

  • Nakajima, Kyouhei;Umemura, Atsushi;Takahashi, Rion;Tamura, Junji
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제2권3호
    • /
    • pp.342-348
    • /
    • 2013
  • As a number of wind power generation systems have been installed in power systems in the world, frequency fluctuations due to output power variations from wind farms have become a serious problem. Battery systems have been studied for smoothing the output variations and decreasing the resulting frequency fluctuations. Among these studies, efficient design of battery systems is one of the most important subjects from a point of view of cost. This paper presents a comparative analysis of the smoothing effect between the conventional moving average method and a new method based on frequency response analysis.

전략적 수요반응이 송전선 혼잡의 시장지배력에 미치는 영향 (Demand Response Effect on Market Power with Transmission Congestion in Electricity Market)

  • 이광호
    • 전기학회논문지
    • /
    • 제66권12호
    • /
    • pp.1705-1711
    • /
    • 2017
  • This paper analyzes the impact of DRA (Demand Response Aggregator) on market power when competing with power generation companies (Gencos) in the electricity market. If congestion occurs in the transmission line, the strategic choice of the power generation company increases exercise of market power. DRA's strategic reduction of power load impacts the strategy of Gencos, which in turn affects the outcome of the load reduction. As the strategy of Gencos changes according to the location of the congested transmission line, the impact on the market depends on the relative location of the congested line and the DRA.

스마트에너지 방식을 적용한 전력신산업 활성화 모델 사례 연구: ESS, 전기차 충전, 전력수요관리 중심으로 (New Energy Business Revitalization Model with Smart Energy System: Focused on ESS, EV, DR)

  • 신재우
    • 한국IT서비스학회지
    • /
    • 제21권6호
    • /
    • pp.117-125
    • /
    • 2022
  • In respond to climate change caused by global environmental problems, countries around the world are actively promoting the advancement of new electricity industries. The new energy business is being applied to energy storage systems (ESS), electric vehicle charging business, and power demand response using cutting edge technologies. In 2022, the Korean government is also establishing a policy stance to foster new energy industries and making efforts to improve its responsiveness to power demand response with the innovative technologies. In Korea, attempts to commercialize energy power are also being made in the private and public sectors to control energy power in houses, buildings, and industries. For example, private companies, local governments, and central government are making all-out efforts to develop new energy industry models through joint investment. There are forms such as establishing energy-independent facilities by region, establishing an electric vehicle charging system, controlling urban lighting systems with Information technologies, and managing demand between power suppliers and power consumers. This study examined the business model applied with energy storage system, electric vehicle charging business, smart lighting, and power demand response based on information communication technology to examine the site where smart energy system was introduced. According to this study, company missions and government tasks are suggested to apply new energy business technologies as economical energy solutions that meet the purpose of use by region, industry, and company.

전력계통 주파수응답 기여도 기반의 전기저장장치 주파수추종서비스 유효용량 산정 (Effective Capacity Calculation of the Electrical Energy Storage providing the Primary Frequency Control Service based on the Contribution to the Frequency Response of Power Systems)

  • 임현옥;최우영;권한나;국경수
    • 전기학회논문지
    • /
    • 제66권11호
    • /
    • pp.1561-1567
    • /
    • 2017
  • This paper calculates the effective capacity of EES providing the primary frequency control service based on its contribution to the frequency response of the power system. The amount of governor response from conventional generators which can be replaced by the primary frequency control from EES keeping the frequency response of the power system is defined as the effective capacity. The proposed method for calculating the effective capacity of EES is verified through case studies employing Korean power system. Furthermore, the application of the effective capacity of EES to power system operation is also discussed.

Response Analysis of MW-Class Floating Offshore Wind Power System using International Standard IEC61400-3-2

  • Yu, Youngjae;Shin, Hyunkyoung
    • 한국해양공학회지
    • /
    • 제34권6호
    • /
    • pp.454-460
    • /
    • 2020
  • In 2019, the Korean government announced the 3rd Basic Plan for Energy, which included expanding the rate of renewable energy generation by 30-40% by 2040. Hence, offshore wind power generation, which is relatively easy to construct in large areas, should be considered. The East Sea coast of Korea is a sea area where the depth reaches 50 m, which is deeper than the west coast, even though it is only 2.5 km away from the coastline. Therefore, for offshore wind power projects on the East Sea coast, a floating offshore wind power should be considered instead of a fixed one. In this study, a response analysis was performed by applying the analytical conditions of IEC61400-3-2 for the design of floating offshore wind power generation systems. In the newly revised IEC61400-3-2 international standard, design load cases to be considered in floating offshore wind power systems are specified. The upper structure applied to the numerical analysis was a 5-MW-class wind generator developed by the National Renewable Energy Laboratory (NREL), and the marine environment conditions required for the analysis were based on the Ulsan Meteorological Buoy data from the Korea Meteorological Administration. The FAST v8 developed by NREL was used in the coupled analysis. From the simulation, the maximum response of the six degrees-of-freedom motion and the maximum load response of the joint part were compared. Additionally, redundancy was verified under abnormal conditions. The results indicate that the platform has a maximum displacement radius of approximately 40 m under an extreme sea state, and when one mooring line is broken, this distance increased to approximately 565 m. In conclusion, redundancy should be verified to determine the design of floating offshore wind farms or the arrangement of mooring systems.

Enhanced Startup Diagnostics of LCL Filter for an Active Front-End Converter

  • Agrawal, Neeraj;John, Vinod
    • Journal of Power Electronics
    • /
    • 제18권5호
    • /
    • pp.1567-1576
    • /
    • 2018
  • The reliability of grid-connected inverters can be improved by algorithms capable of diagnosing faults in LCL filters. A fault diagnostic method during inverter startup is proposed. The proposed method can accurately generate and monitor information on the peak value and the location of the peak frequency component of the step response of a damped LCL filter. To identify faults, the proposed method compares the evaluated response with the response of a healthy higher-order damped LCL filter. The frequency components in the filter voltage response are first analytically obtained in closed form, which yields the expected trends for the filter faults. In the converter controller, the frequency components in the filter voltage response are computed using an appropriately designed fast Fourier transform and compared with healthy LCL response parameters using a finite state machine, which is used to sequence the proposed startup diagnostics. The performance of the proposed method is validated by comparing analytical results with the simulation and experimental results for a three-phase grid-connected inverter with a damped LCL filter.

수요반응 시스템에서의 응용 프로토콜 분석 (Analysis of Application protocol for Demand response System)

  • 박재정;김진영;서종관;이재조
    • 한국위성정보통신학회논문지
    • /
    • 제8권2호
    • /
    • pp.56-61
    • /
    • 2013
  • 최근 들어 급격하게 증가하는 전력 수요와 더불어, 전력의 효율적인 소모를 위한 다양한 방법이 제시되고 있다. 그 중 가장 대표적인 예가 바로 스마트 그리드에 기반 한 수요반응 시스템이다. 이는 기존의 수동적이고 일방적인 전력 수요가 아닌, 서비스 공급자와 소비자의 통신을 통한 효율적인 전력 소모가 가능한 시스템이다. 이러한 수요반응 시스템은 대부분 이더넷, TCP/IP 기반의 HTTP통신을 활용하며, 현재는 하나로 정의되어 있지 않은 다양한 통신 응용 프로토콜이 존재한다. 본 논문에서는 이러한 수요반응에서 응용할 수 있는 프로토콜들의 종류와 그 응용에 관한 내용에 대하여 분석한다.

A practical challenge-response authentication mechanism for a Programmable Logic Controller control system with one-time password in nuclear power plants

  • Son, JunYoung;Noh, Sangkyun;Choi, JongGyun;Yoon, Hyunsoo
    • Nuclear Engineering and Technology
    • /
    • 제51권7호
    • /
    • pp.1791-1798
    • /
    • 2019
  • Instrumentation and Control (I&C) systems of nuclear power plants (NPPs) have been continuously digitalized. These systems have a critical role in the operation of nuclear facilities by functioning as the brain of NPPs. In recent years, as cyber security threats to NPP systems have increased, regulatory and policy-related organizations around the world, including the International Atomic Energy Agency (IAEA), Nuclear Regulatory Commission (NRC) and Korea Institute of Nuclear Nonproliferation and Control (KINAC), have emphasized the importance of nuclear cyber security by publishing cyber security guidelines and recommending cyber security requirements for NPP facilities. As described in NRC Regulatory Guide (Reg) 5.71 and KINAC RS015, challenge response authentication should be applied to the critical digital I&C system of NPPs to satisfy the cyber security requirements. There have been no cases in which the most robust response authentication technology like challenge response has been developed and applied to nuclear I&C systems. This paper presents a challenge response authentication mechanism for a Programmable Logic Controller (PLC) system used as a control system in the safety system of the Advanced Power Reactor (APR) 1400 NPP.