• Title/Summary/Keyword: Power Quality Characteristics

Search Result 1,193, Processing Time 0.029 seconds

Quality Characteristics of Barley Leaves Tea White Bread with Hemicellulase (헤미셀룰라아제를 첨가한 보리잎차 식빵의 품질 특성)

  • Yeom, Kyung-Hun;Kim, Mun-Yong;Chun, Soon-Sil
    • The Korean Journal of Food And Nutrition
    • /
    • v.23 no.2
    • /
    • pp.178-185
    • /
    • 2010
  • Barley leaves tea white bread were prepared by the addition of 0.005, 0.010, 0.015, and 0.020% hemicellulase to flour of the basic formulation. The experiments and control were then compared in terms of quality characteristics, including pH, total titratable acidity, fermentation power of dough expansion, specific volume, baking loss, moisture content, color, textural characteristics, internal surface appearances, and sensory qualities in order to determine the optimal ratio of hemicellulase in the formulation. There were no significant differences in pH and total titratable acidity of dough and bread among the experiments. Fermentation power of dough expansion were increased as incubation time increased. Bread made by the addition of hemicellulase had significantly higher specific volume than the control group. However, lightness and yellowness showed the reverse effect. Greenness was not significantly different among the samples. Baking loss was the highest at the 0.020% addition level, and moisture content was maximal with the 0.010% addition, while the lowest in the control bread samples. As hemicellulase contents increased, harness and fracturability decreased. Resilience was maximal with the 0.015% addition, and was minimal in the 0.005% group. In the sensory evaluation, color, flavor, softness, overall acceptability, barley leaves flavor, delicious taste, astringency, bitterness, and off-flavor were not significantly different among the samples. In coclusion, the results indicate that adding 0.010% hemicellulase in barley leaves tea white bread is optimal for quality and provides a product with reasonably high overall acceptability.

A Study on Developing the Simulation Model of Micro-Sources (마이크로소스의 EMTDC 시뮬레이션 모델 개발에 관한 연구)

  • Son, Kwang-Myoung
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.8
    • /
    • pp.24-32
    • /
    • 2005
  • Micro-source units having power ratings in thousands of watts can provide power quality with higher reliability and efficiency than the conventional large scale units. Since these units are small and easy to install, they are clustered with loads creating micro-grid services to customer sites such as office buildings, industrial parks and homes. Micro-sources adopt voltage source inverter to ensure the power quality of sensitive loads. This paper deals with the connection of micro-sources into the system grid EMTDC modeling of the grid connected micro-sources at the power frequency range are proposed and the characteristics of the control system parameters are investigated. Simulation results show that the micro-grid system with two micro-sources has good dynamic characteristics.

Statistical Characteristics of Pollutants in Sterm Flow (하천오염인자의 통계적 특성)

  • 황임구;윤태훈
    • Water for future
    • /
    • v.14 no.4
    • /
    • pp.19-26
    • /
    • 1981
  • The auto-and cross-correlation function, power spectrum, coherence function and Markov model are applied to investigate the statistical characteristics of discharge and each factor of water quality and the interrelation-ship between the variation of discharge and water quality factors. The analysis of discharge, dissolved oxygen and electric conductivity, which were only obtainable data at the Indogyo gagining station in the downstream of the Han River, clearly showed that they hace distinct period of 12 months and three different periods of 6, 4 and 3 months weaker than the former. The cross-correlation between the discharge and water quality(DO, COND) is rather weak and the crosscorrelation function has its peak at lag one. It is considered therefrom that the variation of discharge behaves on water quality facotrs with one day's difference. In the examination of linear regression model for the serial generation and predictive measures, discharge series is fit to first and second order Markov model and DO, COND to first order Markov model.

  • PDF

On-Demand Power-Efficient QoS Routing Algorithm over Mobile Ad Hoc Networks (MANET에서의 온-디멘드 방식의 전력 효율적인 QoS 라우팅 알고리즘)

  • Lee, Zae-Kwun;Song, Hwang-Jun
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.32 no.9A
    • /
    • pp.923-930
    • /
    • 2007
  • This paper presents MAPER, a media-aware power efficient routing algorithm over mobile ad hoc networks. Generally, multimedia services need various quality of service over the network according to their characteristics and applications. But it is not easy to guarantee quality of service over mobile ad hoc networks since the resources are very limited and time-varying. Furthermore only a limited power is available at mobile nodes, which makes the problem more challenging. Now, we propose an effective routing algorithm over mobile ad hoc networks that provides the stable end-to-end quality of service with the minimum total power consumption. Finally, experimental results are provided to show the performance of the proposed algorithm.

Power Quality Analysis and Failure Survey of Earth Leakage Breakers in Factory Electrical Installation (공장전기설비의 누전차단기 오동작 조사 및 전력품질분석)

  • Lee, Sang-Ick;Choe, Gyu-Ha
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.13 no.1
    • /
    • pp.15-21
    • /
    • 2008
  • This paper presented a actual conditions on a false-tripping of ELB(Earth Leakage Breakers) and an assessment of the harmonics due to non-linear electronic equipment such as personal computers, rectifier, electric furnace and test equipments in factory electrical installation. Actual conditions on a failure of ELB were surveyed and analyzed by making up a question to safety managers of factory electrical installation. Also, power quality measurements such as harmonic currents, voltage and current waveform and current imbalance were made at various factory electrical installation where nuisance tripping of ELB is often occurred. The results of this study can be used in making decisions regarding cause of ELB trip and operating and tripping characteristics test of ELB when subjected to distorted current waveform.

The empirical study on e-learning quality and its relevant constructs (이러닝 품질과 관련 변인에 대한 실증연구)

  • Lee, Misook
    • Journal of Korean Society for Quality Management
    • /
    • v.45 no.4
    • /
    • pp.917-932
    • /
    • 2017
  • Purpose: This study aims to identify the most important quality construct among system quality, information quality, and service quality, which are integrated as the second-order construct; perceived quality, and to investigate the relationship between perceived quality, learner satisfaction, learner enjoyment, switching cost, and learner loyalty. Method: Data were collected from learners who had taken e-learning course, and the analysis was conducted in two phases. The first phase described demographic characteristics using SPSS23.0; the second phase involved the second order CFA of perceived quality and the analysis of measurement model and structural model through AMOS 23.0. Results: (1) The explanatory power of system quality, information quality, and service quality appears to be almost equal; (2) Perceived quality positively influences only both learner satisfaction and switching cost; (3) Only learner satisfaction positively influences learner loyalty and switching cost negatively influences learner loyalty. Conclusion: Learner enjoyment does not play an important role in this study, which could be extrapolated in regard to the characteristics of sample. The respondents are over high school students, who emphasize on the acquisition of knowledge rather than enjoyment. Additionally, the result implies that respondents show low loyalty in the high switching cost.

A Study on the Output Characteristics Comparison of High Frequency Resonant Inverter Type X-ray Generators in Short Exposure Time (고주파 공진형 인버터식 X-선 장치의 단시간 출력특성 비교 연구)

  • 정수복;이성길;임홍우;백형래
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.4 no.1
    • /
    • pp.66-72
    • /
    • 1999
  • This paper deals with the output characteristics of resonant PWM inverter type X-ray generators connected to different DC power units i.e. a single phase full bridge rectifier, a three phase full bridge rectifier and a power storage unit(PSU). The quality of X-ray beam depends on the pulsating waveforms of DC voltage supplied to the X-ray tube. In a X-ray generator, the waveform of DC output voltage can be affected from affected from harmonic distortion of DC input power. When a tube voltage waveform is distorted, the property of X-ray beam such as reproducibility, linearity and dose can be reduced. Therefore, we compared DC output waveforms and dose with three type of DC power units and show the experimental results in this paper.

A Study on Optimization of the Vehicle Intake System for Obtaining Sporty Sound Quality (스포티 음색 구현을 위한 자동차 흡기 시스템의 최적화 연구)

  • You, C.J.;Yun, T.M.;Kang, C.K.;Lee, J.E.
    • Journal of Power System Engineering
    • /
    • v.14 no.2
    • /
    • pp.55-59
    • /
    • 2010
  • In the study, it is considered sporty car as 1400cc entry cars using sound generator. These cars are required special sound quality, also sporty sound quality. The operational principle of this sound generator system is that on the operation of the engine intake valves caused pulsating is to shake the membrane of the sound generator on the inside of the driver front dash panel through the intake manifold, which will deliver the required sound quality and tone. For the component constructed sound generator, main design parameters are selected and optimized using the daguchi's method. The results are as follows; The C2 sound level must be minimized and C4 level must be maximized. And also overall level keeps linear characteristics.

An Isolated Power System Based on Variable Speed Engine Generator with Super-capacitor (슈퍼캐패시터와 가변속 엔진발전기를 이용한 독립형 전원 시스템)

  • Lee, Joon-Hwan;Lee, Seung-Hwan;Sul, Seung-Ki
    • Proceedings of the KIPE Conference
    • /
    • 2007.11a
    • /
    • pp.15-17
    • /
    • 2007
  • The variable speed engine generator set is interested for an isolated power system due to reduced fuel consumption and less emission. However, because of sluggish dynamic behavior of the internal combustion engine the power quality would be degraded during the sudden load power surge, where the power required by the load is not available by the engine due to the reduced engine speed. An isolated power system based on variable speed engine with a super-capacitor bank improves dynamic characteristics under sudden load change, and power quality, fuel consumption, and pollutants can be reduced remarkably. Also, it is verified by the computer simulation that the inverter of 3phase-4leg is compatible to the isolated power system with unbalanced load. In this paper, the feasibility of the system has been verified based on a 26kw commercial diesel engine system.

  • PDF

A New Control Method for an Adaptive Noise Canceller Using Stochastic difference between Voice and Noise Signals Power Change

  • Nishi, H.;Kakinoki, T.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.2362-2367
    • /
    • 2005
  • This paper reports a technique for discriminating double talk and echo path change using the stochastic characteristics of power change for an adaptive noise canceller. The causes of rapid error increasing are double talk and echo path change. When the echo path is changed, the system corrects the impulse response in order to reduce the error. However, in the case of double talk, the system has to suspend the updating impulse response in order to maintain the quality of the voice signal. In the conventional system, it was difficult to discriminate between the two situations. In this research, the stochastic characteristics of the voice power change in the double talk period were experimentally verified to be different from the power change during echo path changing. Based on the results, a new double talk detection method is proposed.

  • PDF