• Title/Summary/Keyword: Power Plant Park

Search Result 1,381, Processing Time 0.032 seconds

Numerical Investigation of the Flow and Mixing Characteristics with the Static Mixer in a Catalytic Combustor for the MCFC Power Plant System (MCFC 발전시스템 적용 촉매연소기의 혼합 특성 향상을 위한 Static Mixer의 유동에 관한 수치적 연구)

  • Kim, Chong-Min;Park, Nam-Seob;Kim, Man-Young
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.33 no.3
    • /
    • pp.149-155
    • /
    • 2009
  • In this work a numerical study to find the characteristics of the internal flow and mixing process has been conducted in a static mixer used in the system of catalytic combustor of the fuel cell power plant. After introducing the model description and final governing equations the present numerical approach is applied to the analysis of static mixer, which may have one or more helical elements inside the circular tube by changing such various parameters as incoming mass flow rates and the number of helical elements. The results show that although the static mixer is efficient in mixing fuel and air, more optimization processes are required to achieve the appropriate mixing characteristics in front of the honeycomb type catalytic combustor used in the MCFC power plant

Research Integrated Change Process for Configuration Management of Construction Nuclear Power Plant (건설원전 형상관리를 위한 통합변경프로세스 연구)

  • Park, Youjin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.05a
    • /
    • pp.231-232
    • /
    • 2016
  • Configuration Management (CM) is a process of identifying and documenting the characteristics of a Structures, Systems and Components (SSCs), and of ensuring that changes to these characteristics are properly assessed, approved, issued, implemented and verified. There are requirement management, change control, facility configuration information management for CM activities. In order to improve safety of Nuclear Power Plant(NPP), it is necessary to manage change item systematically. Existing CM concept is focused on the NPP in operation. On the other hand, NPP under construction is difficult to efficiently manage the change because of different change process from varoius stake-holders. This research considers method of consolidation change process for NPP to ensure that approved changes are accurately reflected in the design requirements, facility configuration information, and the physical configuration.

  • PDF

Vibration Reduction of Vertical Pumps Used in the Power Plant Circulating Water System (발전소 순환수계통 수직펌프의 진동저감에 관한 연구)

  • Park, Hyeok;Yoo, Ho-Seon
    • Plant Journal
    • /
    • v.9 no.1
    • /
    • pp.43-49
    • /
    • 2013
  • In this study, the natural frequency of the actual operating vertical pump in the P combined cycle power plant is measured and the cause of high vibration is determined by using fluid-structure coupled vibration theory. Choosing the vibration reduction plan suited for field conditions and using the numerical analysis verify effectiveness of the plan. The plan is applied to the actual pump and the empirical experiments are conducted.

  • PDF

Characterization of Creep Resistance for HAZ Structures in Weldment of USC Power Plant (USC 발전설비 용접부 HAZ 조직의 내 크리프 특성)

  • Baek, Seung-Se;Park, Jeong-Hun;Lee, Song-In;Gwon, Il-Hyeon;Lee, Dong-Hwan;Yang, Seong-Mo;Yu, Hyo-Seon
    • Proceedings of the KWS Conference
    • /
    • 2005.06a
    • /
    • pp.250-252
    • /
    • 2005
  • T/P92 steels are created for using USC boiler tube and header in next generation power plant. SP-Creep test and tensile creep test are performed to characterize creep for local structures of T/P92 steel weldment. The results are shown that P92 steel weldment is clearly superior than that of X20CrMoV121 steel weldment, which is widely used in supercritical power Plant. while fine gram HAZ is most weakest in X20 steel weldment, coarse grain HAZ is most weakest in P92.

  • PDF

Multiobjective PI Controller Tuning of Multivariable Boiler Control System Using Immune Algorithm

  • Kim, Dong-Hwa;Park, Jin-Ill
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.3 no.1
    • /
    • pp.78-86
    • /
    • 2003
  • Multivariable control system exist widely in many types of systems such as chemical processes, biomedical processes, and the main steam temperature control system of the thermal power plant. Up to the present time, Pill Controllers have been used to operate these systems. However, it is very difficult to achieve an optimal PID gain with no experience, because of the interaction between loops and gain of the Pill controller has to be manually tuned by trial and error. This paper suggests a tuning method of the Pill Controller for the multivariable power plant using an immune algorithm, through computer simulation. Tuning results by immune algorithms based neural network are compared with the results of genetic algorithm.

The Properties of Supper Flowing Concrete using Class C Fly Ash (C급 플라이애쉬를 사용한 초유동 콘크리트 특성)

  • Won, Cheol;Kwon, Yeong-Ho;Kim, Dong-Seok;Park, Chil-Lim
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1996.10a
    • /
    • pp.276-282
    • /
    • 1996
  • This study dealt with the properties for fly ash of combined heat power plant and application for concrete industry. For this purpose, fly ash of ulsan combined heat power plant was analyzed for physical and chemical properties and tested the properties of the super flowing concrete. As results of fly ash, contents of SiO2 and Al2O3 in the fly ash of Ulsan were less than those of thermal power plant(Boryung), but contents of CaO were ten times as much as those of Boryung. In order to satisfy the properties of the Super Flowing Concrete using class C fly ash, mixing conditions were determined the optimum water-binder(w/b), volume ratio of fine aggregates(Sr) and coarse aggregates(Gv).

  • PDF

Study on the Seismic Analysis of the Reactor Vessel Internals (원자로내부구조물의 지진해석에 관한 연구)

  • Jhung, Myung-Jo;Park, Keun-Bae;Hwang, Won-Gul
    • Nuclear Engineering and Technology
    • /
    • v.25 no.1
    • /
    • pp.28-36
    • /
    • 1993
  • Much effort is being done to standardize the PWR-type nuclear power plant in Korea. This paper presents the development of seismic design criteria for the reactor internals as a part of the standardization program for nuclear power plant. The seismic design loads of the reactor internals are calculated using the reference input motions of reactor vessel taken from Yong-gwang Nuclear Power Plant Units 3 and 4. An overview of analysis related to the basic parameters and methodologies is presented. Also, the response of internal components for the reactor vessel motions is carefully investigated.

  • PDF

The Rebar Modulation Method in the Area of the Nuclear Power Plant Structures (원전구조물 부위별 철근모듈화 방안 연구)

  • Lee, Byung-Soo;Bang, Chang-Joon;Kim, Hun Jin;Lim, Sang-Joon;Park, Jong-Hyuk
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.11a
    • /
    • pp.15-16
    • /
    • 2013
  • Because of the complicated shape and the overcrowded arrangement of rebar, there are some problems in applying the rebar modulation for the Nuclear Power Plant Structures. In order to resolve these problems, we have been studying the rebar modulation method applying techniques of the high strength rebar for NPP Structure. After reviewing the rebar drawing of the NPP structures and performing the mock-up test, the rebar modulation method in the various area of the NPP Structure has been established. I will introduce this method and the future plan of the research.

  • PDF

Improvement of a PID Function Block of a Domestic DCS (국산 분산 제어 시스템의 PID 기능 블록 개선(II))

  • Byun, S.H.;Park, D.Y.;Jeong, K.S.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07d
    • /
    • pp.2108-2110
    • /
    • 2001
  • Used analog control systems have been converted into digital control systems due to performance degradation and difficulty of maintenance. There are few domestic DCS (Distribued Control System)s that have been applied to power plant. To apply a domestic DCS to power plant, the reliability, redundacny, and fault tolerance of DCS is important. Besides those items, the control action of control function block is also important. In this paper, we describe the requirements that PID control function block has to have, and implement a PID control function block that satisfies those requirements. Finally, real control result using an implemented PID function block in thermal power plant shows the validity of an implemented PID control function block.

  • PDF

Tidal regime change due to the Siwha tidal power plant operation in the Yellow and East China Seas

  • Kang, Sok-Kuh;Yum, Ki-Dai;Lee, Kwang-Soo;Jang, Chan-Joo;Park, Jin-Soon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.513-516
    • /
    • 2006
  • The feasibility study for tidal power plant (TPP) has been carried out for the Siwha area inside the Kyunggi bay of the Kyunggi Bay of the Yellow and East china Seas, by KORDI (Korea Ocean Research and Development Institute) and continuing research works for tidal energy development are under progress in the several sites inside the Kyunggi Bay. In this paper we describes some results of the modeling efforts in relation the tidal regime change by Siwha TPP operation, as well as other coastal oceanographic research works involved in TPP development in the coastal region.

  • PDF