• 제목/요약/키워드: Power Performance Curve

검색결과 293건 처리시간 0.036초

G/T 199톤급 우리나라 대형선망 등선 겸용 운반어선의 선형설계에 관한 연구 (A Study on the Hull Form Design of a G/T 199ton Class Fishing Boat for Both Fish-luring Lighting and Fish Carrying in Korean Large Purse Seiner Fishing System)

  • 박애선;이영길;진송한
    • 대한조선학회논문집
    • /
    • 제49권5호
    • /
    • pp.391-399
    • /
    • 2012
  • This paper presents a method of hull form design for the assistant vessel which is used both as a lighting boat and a fish carrying boat for the fleet of newly formated purse seiner vessels. The optimum hull form parameters are searched by the Sequential Quadratic Programing(SQP) method with the power estimation method of Van Oortmerssen. The prismatic curve is redesigned from that of the reference hull by the Lackenby method. Through the modification of the hull form by using a CAD system, the design procedure is completed. The resistance performances of the reference and the modified hull forms are estimated by using a numerical simulation method. Also, the estimation of seakeeping ability and stability for the modified hull forms are carried out. And then, an optimum hull form is proposed for the designed hull form. Ship model tests for the reference and the designed hull forms are carried out at ship model basin. The results of the experiments show that the effective horse power of the designed hull form is about 22% smaller than that of the reference hull form at design speed. The designed hull form proposed in this study will contribute to the development of the hull form for Korean large purse seiner vessels.

液休용 이젝터 性能에 관한 CAD와 實驗結果와의 比較 (The Comparison of Experimental Results of Liquid Ejector Performance to Predictions by the Computer Aided Design Program)

  • 김경근;김명환;홍영표;고상철
    • 대한기계학회논문집
    • /
    • 제12권3호
    • /
    • pp.520-527
    • /
    • 1988
  • 본 연구에서는 액체용 이젝터의 성능을 결정하는 여러가지 제약인자중 특히 레이놀즈수 변화에 따른 구동노즐의 면적비 및 목부길이가 액체용 이제터성능에 미치 는 영향을 체계적인 실험을 통하여 연구함으로써 기 개발된 CAD용 전산프로그램의 타 당성을 보다 세밀히 검토하고 이에 보완을 가하는데 연구의 목적이 있다.

강제진동을 받는 강판 콘크리트 (SC) 벽체에서 스터드의 성능평가를 위한 해석적 연구 (Analytical Study for Performance Evaluation of Studs for Steel Plate Concrete (SC) Walls subjected to Forced Vibration)

  • 이성태
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제20권3호
    • /
    • pp.75-82
    • /
    • 2016
  • 이 연구에서는 SC 전단벽의 전단 연결재인 스터드의 배치와 형상이 SC 전단벽의 거동에 미치는 영향을 살펴보기 위해 전단벽체가 강제진동을 받을 때의 거동을 해석적으로 검토하였다. 이를 위해 서로 다른 배치간격과 형상의 스터드가 배열된 SC 전단벽을 대상으로 유한요소해석을 수행하였다. 그 결과, 시간이력해석으로부터 구한 감쇠비가 파워반감대역폭법이 전반적으로 높게 그리고 적합지수함수법이 가장 낮은 수준으로 산정했으며 설계강도 절반정도에서의 감쇠비는 3.0~4.2%로, 설계강도에서는 4.1~5.2%로 나타남을 알 수 있었다. 또한, 개선된 스터드를 사용할 때, 감쇠비가 약간 감소하였고 DS1과 DS2 간에는 일관된 결과가 나타나지 않았다. 스터드의 간격이 필요이상 증가할 경우, 고유진동수가 감소하고 감쇠비가 증가함을 확인하였다.

광튜브와 디쉬형 집광기의 자연채광 성능 예측 및 비교 연구 (A Comparative Study on Daylighting Performance Prediction of Light Tube and Dish Concentrator)

  • 오승진;한현주;천원기
    • 에너지공학
    • /
    • 제21권2호
    • /
    • pp.124-132
    • /
    • 2012
  • 본 연구에서는 북측창을 가진 강의실 내의 불균형적인 실내 조도차이를 개선하기 위해 두 가지의 자연채광시스템을 적용하였을 경우에 대하여 Photopia를 이용한 성능 시뮬레이션을 수행하였다. 특히, 본 연구에서는 태양고도가 최고 $80^{\circ}$ 이르는 하지에 청천공 상태 하에서의 태양고도에 따른 각 시스템의 배광분포곡선을 구하고 이를 이용하여 실내 조도 등을 분석하였다. 작업면의 경우, 창측과 복도측의 평균 조도차가 1000lx를 초과하였는데 시스템 설치 후에는 그 차이가 상당히 줄어드는 것으로 나타났다. 광튜브 시스템 설치시 906lx에서 603lx로 감소하였으며, 디쉬형 시스템은 308lx까지 줄어들었다. 광튜브의 성능은 태양고도에 영향을 크게 받았으며 디쉬형 집광기는 지속적인 태양추적으로 인하여 태양고도에 관계없이 일정한 성능을 보여주었다.

공정프로파일 모니터링에서 웨이블릿기 반 T2-검정과 신경회로망의 성능비교 (Performance Comparisons of Wavelet Based T2-Test and Neural Network in Monitoring Process Profiles)

  • 김성준;최덕기
    • 한국지능시스템학회논문지
    • /
    • 제18권6호
    • /
    • pp.737-745
    • /
    • 2008
  • 최근 공정 및 계측기술이 발전함에 따라 밀링, 그라인딩, 브로칭 등 공정작업의 온라인 모니터링에 대한 관심이 높아지고 있다. 온라인 모니터링 시스템은 공구의 마모나 파손 등과 같은 공정변화를 가급적 조기에 발견함으로써 설비를 보호하고 불필요한 비용의 발생을 억제하는 데 그 목적을 두고 있다 본 논문에서는 온라인 공정관측 데이터가 프로파일로 주어질 때 웨이블릿변환을 이용한 $T^2$-검정과 신경회로망의 모니터링 성능에 대해 고찰한다. 2006년 Axinte가 제시한 절삭력 데이터를 이용하여 수치실험을 수행한 결과, 웨이블릿기반 $T^2$는 양호한 검출력을 나타냈지만 그 검사특성은 자기상관에 매우 민감하게 반응하였다. 반면, 자기상관의 존재 하에서도 신경회로망은 $T^2$-검정에 비해 매우 안정적인 검사특성을 갖는 것으로 나타났다. 이는 웨이블릿기반 $T^2$-검정에 노이즈분석을 위한 적응적인 요소가 필요하다는 점을 시사한다

고온 고분자 막 전해질 연료전지 캐소드의 가스 확산층 및 바인더 함량에 따른 완화 시간 분포(DRT) 저항 분석 (Resistance Analysis by Distribution of Relaxation Time According to Gas Diffusion Layers and Binder Amounts for Cathode of High-temperature Polymer Electrolyte Membrane Fuel Cell)

  • 김동희;정현승;박찬호
    • 한국수소및신에너지학회논문집
    • /
    • 제34권3호
    • /
    • pp.283-291
    • /
    • 2023
  • The physical properties were analyzed for four gas diffusion layers, and gas diffusion electrodes (GDEs) for the cathode of high-temperature polymer electrolyte membrane fuel cell were fabricated through bar coating with three binder to carbon (B/C) ratios. Among them, The GDE from JNT30-A6P showed a significant change in secondary pore volume at a B/C ratio of 0.31, which had the largest pore volume among all GDEs. In the polarization curve, JNT30-A6P GDE showed the best membrane electrode assembly (MEA) performance with a peak power density of 384 mW/cm2 at a a B/C ratio of 0.31. From the distribution of relaxation time analysis, the peak 1 corresponding to mass transfer resistance of oxygen reduction reaction (ORR) was significantly reduced in the JNT30-A6P GDE. This is the result that when the binder content decreased, the volume of the secondary pore increased, and the mass transfer resistance of ORR decreased, which played an essential role in the MEA performance.

22 kV 케이블의 누설전류 및 절연저항의 선형적 변화 (A Linear Change of Leakage Current and Insulation Resistance of 22 kV Cables)

  • 엄기홍;이관우
    • 한국인터넷방송통신학회논문지
    • /
    • 제15권3호
    • /
    • pp.169-173
    • /
    • 2015
  • 이 논문은 사용한지 13년 지난 운전 중 22 kV 케이블시스템을, 7년 동안 절연저항을 측정하여 그 결과를 연구한 논문이다. 우리는 발전소에서 설치 운전 중인 고전압 케이블이 시간에 따라 성능이 악화되는 현상의 추세를 결정하는 수명지수를 파악하였다. 위한 논문이다. 케이블 시스템은 시간에 따라 절연 저항이 감소한다. 초기 케이블 시스템은 아레니우스 열화 곡선을 따른다. 초기에는 수명 지수 n값이 9로 설계하였고, 이후 n값을 상향하여 16으로 결정하였다. 이유는 고전압에서 케이블이 동작할 경우, n값이 클 때 파괴특성이 높지 않고, n값이 낮은 값에서 파괴특성이 높았기 때문이다. 그러나 전압열화에 의하여 와이블 프롯을 따른 v-t 특성에 의하여 n값은 10~11의 값을 갖는 것을 확인하였다. 과거 케이블 설계 시 정한 n=9의 이론적 근거와 n=16 으로 높아진 원인을 파악함으로써 누설 전류 및 절연 저항의 선형적인 변화를 확인하였다. 단기적으로는 운전 중 케이블 시스템의 진단 평가에 활용되며, 장기적으로는 발전소 부하에서 동작 중인케이블 시스템의 설치 및 운영에 있어서 원가를 절감하기 위한 노력에 기여하고자 한다.

무선 USN 멀티홉 중계 노드에서 루프백 신호의 제거 성능 (The cancellation performance of loop-back signal in wireless USN multihop relay node)

  • 임승각;강대수
    • 한국인터넷방송통신학회논문지
    • /
    • 제9권4호
    • /
    • pp.17-24
    • /
    • 2009
  • 본 논문은 USN 무선 네트워크에서 16-QAM 수신 신호의 멀티 홉 중계를 수행하는 경우 적응 신호 처리 알고리즘을 적용한 루프백 간섭 신호의 제거 성능에 관한 것이다. 이를 위하여 USN 환경에서는 노드간의 중계 기능에 의해 원거리 스테이션과의 정보 교환이 필요하게 되는데, 중계 노드에서는 송신기와 수신기 안테나를 공동 이용하거나 매우 근접하여 위치하므로서 재송신 신호가 수신측으로 궤환되거나, 비선형 소자를 사용하므로서 발생되는 루프백 간섭 신호가 존재하게되므로 한정된 주파수와 전력 자원을 사용하는 USN 시스템의 성능을 크게 저하된다. 이를 개선하여 향상된 시스템 성능 및 멀티홉 성능을 얻기 위해 중계 노드의 수신부 전단에서 원하지 않는 루프백 간섭 신호를 제거하기위한 적응 신호 처리 알고리즘의 적용이 필요하게 된다. 적응 신호 처리를 위해서는 먼저 스펙트럼 효율이 우수한 16-QAM 신호를 대상으로 하여 수렴 특성이 우수하고 H/W 로 구현할 때 발생되는 유한장 문제점을 해결할 수 있는 QR-Array RLS 알고리즘을 사용하였으며, 루프백 간섭 신호의 제거 성능으로 수신 신호 성상도 및 learning curve에서 기존의 RLS 보다 우월함을 컴퓨터 시뮬레이션을 통해 확인할 수 있었다.

  • PDF

직상류 계측유량경계조건과 분포형모델을 이용한 대규모 다목적댐 홍수유입량 산정 (Flood Inflow Estimation at Large Multipurpose Dam using Distributed Model with Measured Flow Boundary Condition at Direct Upstream Channels)

  • 홍석현;강부식
    • 대한토목학회논문집
    • /
    • 제35권5호
    • /
    • pp.1039-1049
    • /
    • 2015
  • 대규모 다목적댐 지점의 유입량 산정은 수위-저수용량곡선에 댐 축에서 측정된 수위를 적용하여 시간당 저수량변화를 계산한 후 방류량을 감안하여 산정하고 있으나, 이 방법은 태풍 등 대규모 홍수 시에는 급격한 유입량 증가로 인한 배수위 및 강한 바람 등의 영향으로 저수지내의 수위가 균일하지 않아 유입량 산정 시 오차 원인이 되고 있다. 이 외에 기존 수위-저수용량 곡선 방법에 의한 유입량 계산 시 문제점인 댐건설 이후 유입 퇴사로 인한 저수용량의 변화, 댐 지점에서의 수위관측의 불균일성 등 다양한 불확실성이 존재하므로 이에 대한 오차 규명이 반드시 필요하다. 본 연구에서는 저수지 유입량 분석시 분포형 강우유출모형을 이용한 UBC-3P 기법을 적용하여 모형의 모의능력을 평가하였다. 최종적으로 기존 유역내 유입량 관측치와 비교한 결과 Peak유량과 Total유량에서 결정계수가 0.82~0.99 사이값을 나타내므로 댐 지점에서의 모형의 적합성을 확인하였다.

국내 벤토나이트 완충재의 함수특성곡선 평가 (Evaluation of Soil-Water Characteristic Curve for Domestic Bentonite Buffer)

  • 윤석;전준서;이창수;조원진;이승래;김건영
    • 방사성폐기물학회지
    • /
    • 제17권1호
    • /
    • pp.29-36
    • /
    • 2019
  • 원자력발전소를 운영하게 되면 사용후핵연료와 같은 고준위방사성폐기물이 필연적으로 발생한다. 이러한 고준위방사성폐기물을 처분하기 위해 심층처분방식이 가장 적합한 대안으로 알려져 있으며 고준위방사성폐기물은 공학적방벽과 천연방벽에 둘러 쌓여 지하 500~1,000 m 깊이의 심지층에 처분된다. 이 중 압축 벤토나이트 완충재는 공학적방벽의 가장 중요한 구성요소이다. 완충재는 처분용기와 자연 암반 사이에 위치해 있기에 주변 지하수 흐름으로부터 처분용기를 보호하고 처분 용기로부터 핵종이 유출되는 것을 저지하는 역할을 한다. 주변 지하수 흐름으로 인한 완충재의 불포화 함수특성 규명은 전체 공학적방벽의 성능을 평가하는데 있어 매우 중요하다고 할 수 있다. 따라서 본 연구에서는 실내 시험을 수행하여 국내 압축 벤토나이트 완충재의 건조밀도, 구속조건 여부, 그리고 건조 및 포화 이력에 따른 압축 벤토나이트 완충재의 함수특성곡선을 도출하여 분석하였다. 구속 조건하에서 건조밀도에 따른 함수특성곡선은 큰 차이를 보이지 않았다. 또한 비구속 조건이 구속 조건에 비해 보다 큰 수분흡입력을 나타냈으며, 아울러 포화 과정보다 건조 과정에서 보다 큰 수분흡인력이 측정되었다.