• 제목/요약/키워드: Power Measurement

검색결과 4,641건 처리시간 0.029초

케이블 절연열화진단과 실 계통 적용 (Insulation Diagnostics of Power Cables and Application to Real Distribution System)

  • 이동영;김주용;송일근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 D
    • /
    • pp.1569-1571
    • /
    • 1999
  • In this work, we have performed the application experiment for real distribution line to diagnose the underground power cables using DC voltage decay measurement system. We have also performed the Isothermal Relaxation Current test for the same distribution line using KDA-l. We could confirmed possibility of grading the insulation aging state of underground power cables. Therefore, we conclude that it is possible to apply DC voltage decay method to the real distribution line.

  • PDF

전력(電力)케이블 열화진단(劣化診斷) 기술(技術)의 동향(動向) (THE TREND OF DIAGNOSTIC METHODS FOR POWER CABLE)

  • 한기만;김동욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 B
    • /
    • pp.779-783
    • /
    • 1992
  • In recent years, it is strongly required to supply high quality electrical power without insulation failure in distribution power cables. Therefore the exact measurement and judgment ar out deterioration degree of cables are essential to increase that supplying reliability. This paper will introduce various diagnostic methods of off-line and live-line cables also propose the judgement criteria and newly trend of diagnostic technique at present.

  • PDF

산업용 부하설비의 고조파 측정 및 분석 (Harmonics Measurement and Analysis on Industrial Load Installation)

  • 임재윤;이종필;지평식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.110-112
    • /
    • 2003
  • Harmonics happened due to nonlinear systems such as UPS, SCR controlled motors, and fluorescent lighting in distribute power system is very important subject to optimal operate and control of power system. Harmonics sometimes takes place incorrect operation of protective relaying system under normal condition on power system. This paper presents the actual recording data of transformer located at substation of industrial installation for harmonic analysis in detail.

  • PDF

A High Voltage, High Side Current Sensing Boost Converter

  • Choi, Moonho;Kim, Jaewoon
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2013년도 전력전자학술대회 논문집
    • /
    • pp.36-37
    • /
    • 2013
  • This paper presents high voltage operation sensing boost converter with high side current. Proposed topology has three functions which are high voltage driving, high side current sensing and low voltage boost controller. High voltage gate driving block provides LED dimming function and switch function such as a load switch of LED driver. To protect abnormal fault and burn out of LED bar, it is applied high side current sensing method with high voltage driver. This proposed configuration of boost converter shows the effectiveness capability to LED driver through measurement results.

  • PDF

RHODIUM SELF-POWERED NEUTRON DETECTOR'S LIFETIME FOR KOREAN STANDARD NUCLEAR POWER PLANTS

  • YOO CHOON SUNG;KIM BYOUNG CHUL;PARK JONG-HO;FERO ARNOLD H.;ANDERSON S. L.
    • Nuclear Engineering and Technology
    • /
    • 제37권6호
    • /
    • pp.605-610
    • /
    • 2005
  • A method to estimate the relative sensitivity of a self-powered rhodium detector for an upcoming cycle is developed by combining the rhodium depletion data from a nuclear design with the site measurement data. This method can be used both by nuclear power plant designers and by site staffs of Korean standard nuclear power plants for determining which rhodium detectors should be replaced during overhauls.

Digital Control of an AC/DC Converter using the Power Balance Control Technique with Average Output Voltage Measurement

  • Wisutmetheekorn, Pisit;Chunkag, Viboon
    • Journal of Power Electronics
    • /
    • 제12권1호
    • /
    • pp.88-97
    • /
    • 2012
  • This paper presents a method for the digital control of a high power factor AC/DC converter employing the power balance control technique to achieve a fast response of the output voltage control. To avoid the effects of an output voltage ripple in the voltage control loop, the average output voltage is sampled and used as a feedback signal for the output voltage controller. The proposed control technique was verified by simulations using MATLAB/Simulink and its implementation was realized by a dsPIC30F4011 digital signal processor to control a CUK topology AC/DC converter with a 48V output voltage and a 250 W output power. The experimental results agree with the simulation results. The proposed control technique achieves a fast transient response with a lower line current distortion than is achieved when using a conventional proportional-integral controller and the power balance control technique with the conventional sampling method.

6kW 풍력발전기의 출력곡선 측정 (Power Curve Measurements on the 6kW Wind Turbine)

  • 유능수;남윤수;이정완;조주석
    • 산업기술연구
    • /
    • 제25권B호
    • /
    • pp.149-157
    • /
    • 2005
  • The power performance monitoring system for a small class of wind turbine is established. The wind turbine power performance characteristics are determined by measured power curve and the estimated annual energy production (AEP). The measured power curve is determined by collecting simultaneous measurements of wind speed and power output at the test site under varying wind conditions. In order to determine the power performance characteristics of the wind turbine accurately, the data are of sufficient quantity and quality shall be corrected according to defined criteria. In this study, the 6kW wind turbine made by Germany Inventus GmbH is examined.

  • PDF

154kV 전력용 변압기의 온도분포에 관한 연구 (The Study on the Temperature Distribution for 154kV Power Transformers)

  • 우정욱;구교선;곽주식;김경탁;권동진
    • 조명전기설비학회논문지
    • /
    • 제25권9호
    • /
    • pp.56-61
    • /
    • 2011
  • The temperature of power transformers is very important factor for power system operation in substation because load capacity and limited lifetime of power transformers are determined by winding temperature. Also, The temperature of power transformers varies with the structure, capacity, operation condition and manufacturers. Thus, it is necessary for temperature distribution to be exactly investigated because of efficient load management and prediction of limited lifetime. Nevertheless, there was no case of analysis as well as measurement of the temperature of power transformers. In this paper, we manufactured the 154kV standard power transformer for the test. And we measured the temperature by the heat run test and analyzed the temperature distribution of transformer.

Measurement and Explanation of DC/RF Power Loci of an Active Patch Antenna

  • Mcewan, Neil J.;Ali, Nazar T.;Mezher, Kahtan A.;El-Khazmi, Elmahdi A.;Abd-Alhameed, Raed A.
    • ETRI Journal
    • /
    • 제33권1호
    • /
    • pp.6-12
    • /
    • 2011
  • A case study of an active transmitting patch antenna revealed a characteristic loop locus of DC power versus RF output power as drive frequency was varied, with an operational bandwidth substantially smaller than the impedance bandwidth of the radiator. An approximate simulation technique, based on separation of the output capacitance of the power transistor, yielded easily visualized plots of power dependence on internal load impedance, and a simple interpretation of the experimental results in terms of a near-resonance condition between the output capacitance and output packaging inductance.